Davis Instruments Vantage Pro2 Press and release 2ND and press Units once, Screen 13 Rain Season

Page 22

Setup Mode

2. Press and release 2ND and press UNITS once.

UNITS

The units used to display rain data toggle between 2ND GRAPH inches and millimeters each time you repeat this key

sequence.

To Display Rain in Metric Units in WeatherLink

Refer to WeatherLink online help for instructions to set the rain collector to 0.2 mm and to select millimeters as the unit for rain.

Screen 13: Rain Season

Because rainy seasons begin and end at different times in different parts of the world, you must specify the month you wish your yearly rain data to

begin. January 1st is the default. The date the rain season begins affects yearly rain rate highs and lows.

Screen 13: Rain Season

1.Press the up and down arrows to select the month for the start of the rainy season.

2.Press DONE to move to the next screen.

Note:

This setting determines when the yearly rain total is reset to zero. Davis Instruments

 

recommends a January rain season setting (the default), unless you reside in the

 

west coast of the United States, the Mediterranean coast, experience dry winters in

 

the Southern Hemisphere, or or are performing hydrology studies in any of these cli-

 

mates. If so, change the rain season setting to July 1st.

 

Screen 14: Serial Baud Rate

 

The Baud Rate screen displays if the console detects that a WeatherLink

 

data logger installed on the console.

 

The console uses a serial or USB port to communicate with a computer. If

 

you are connecting the console directly to your computer, leave the setting

 

at 19200, the highest rate for the port. If you’re using a modem, use the

 

highest setting your modem can handle. The console must be equipped

 

with a WeatherLink data logger to communicate with a computer.

19

Image 22
Contents Vantage Pro2 Console Manual Vantage Pro2 Console Display Features Vantage Pro 2 Console ManualTable of Contents Keyboard & Display Console FeaturesChapter Welcome to Vantage Pro2 Printed on that keyOptional Sensors Vantage Pro OptionsConsole Modes Optional WeatherLink SoftwareOptional Accessories Installing the AC Power Adapter Chapter Installing the ConsolePowering the Console Ies provide backup power for up to four to six weeksInstalling Batteries Connecting Cabled StationsTested and established Installation ManualConsole Location Cabled consoleTable & Shelf Placement Wall Mounting Setup Mode Chapter Using Your Weather StationSetup Mode Commands Screen 1 Active Transmitters Screen 1 Active TransmittersScreen 3 Retransmit Wireless Only Screen 2 Configuring Transmitter IDs Wireless OnlyScreen Screen 4 Time & Date Screen 5 Latitude Screen 6 Longitude Screen 7 Time ZoneScreen 8 Daylight Savings Settings Screen 9 Daylight Savings Status Screen 10 ElevationScreen 11 Wind Cup Size Screen 12 Rain Collector Screen 13 Rain Season Data logger installed on the consolePress and release 2ND and press Units once Screen 14 Serial Baud RateCurrent Weather Mode Clear All CommandSelecting Units of Measure Selecting Weather VariablesSelected variable’s units will change. Repeat Press Wind to select wind speedPress 2ND then press Chill to select Wind Chill Wind Chill is displayed in either Fahrenheit ºF or CenPress 2ND then press Heat to display the Heat Index Night. Any rain accumulated in the last 24 hours displays Press Rainday to display the rain accumulated since 12 midTicker at the bottom of the screen Press 2ND then press Lamps to turn on the backlight for Screen display. Press 2ND then Lamps again to turn the backDisplaying the Forecast Calibrating, Setting, and Clearing VariablesCalibrating Temperature And Humidity Displaying Time & Date or Sunrise & SunsetCalibrate Wind Direction Reading After a moment, the variable you’ve selected beginsReading Calibrating Barometric Pressure Setting Weather VariablesClearing Weather Variables Highs and Lows Mode Viewing Highs and Lows Alarm Mode Four Special AlarmsSetting the Time Alarm Setting AlarmsClearing Alarm Settings Silencing Alarms Graph ModePress Done to silence an alarm when it sounds Viewing Graphs Weather Variable Available Graphs Vantage Pro2 Troubleshooting Guide Chapter Troubleshooting and MaintenanceProblem Solution Rain Console Diagnostic Screens Accessible to a cabled weather stationNumber of packets containing errors that were received Number of missed data packetsReception Diagnostic Screen Console Maintenance One Year Limited WarrantyAppendix a Weather Data Tive humidity 30% even though water vapor content does not changeSor Ity has a large capacity to absorb extra water vaporBarometric Pressure MED for persons with very light skin Pro2 displays UV readings in two scales MEDs and UV IndexSkin Phototype Skin color Tanning & Sunburn history Skin Type Skin Color History of Tanning & Sunburning IIIIndex Values Exposure Category Wireless Communication Specifications Appendix B SpecificationsConsole Console Data Display Specifications Weather Data Specifications Variable Required SensorsThsw Vantage Pro2 Console Icons Forecast