| Vantage Pro2 Troubleshooting Guide | |
|
|
|
|
| |
|
| TABLE | |||
|
|
|
|
|
|
|
| Problem |
| Solution | |
|
|
|
|
|
|
| Dew | Dew Point reading seems | Check calibration numbers for temperature. Remember, dew point | ||
| depends on temperature and outside humidity. Make sure they’re | ||||
| too high or too low | ||||
|
|
| working. |
| |
|
| Outside temperature sensor | Check calibration number and adjust if necessary. ISS or temp sen- | ||
|
| reading seems too high | sor may need to be relocated. See ISS or other transmitter manual. | ||
|
|
|
|
| |
|
|
| Move the console out of direct sunlight. Make sure that the console | ||
|
|
| or sensor is not in contact with an exterior wall that heats up in sun- | ||
|
| Inside temperature sensor | light or when outside temperature rises. Make sure the console or | ||
| Temperature | reading seems too high | sensor is not near a heater or other internal heat source (lamps, ap- | ||
|
| pliances, etc.). Also make sure the console backlight is not on. | |||
|
|
| Check calibration number and adjust if necessary. | ||
|
|
|
|
| |
|
| Outside temperature seems | Check calibration number and adjust if necessary. Sprinklers may | ||
|
| too low | be hitting the ISS radiation shield. Relocate. See ISS manual. |
| |
|
|
|
|
| |
|
|
| Make sure the console or other temperature sensor is not in contact | ||
|
| Inside temperature sensor | with an exterior wall that cools down when outside temperature | ||
|
| drops. Make sure the console or other temperature sensor is not | |||
|
| reading seems too low | |||
|
| near an air conditioning vent. Check calibration number and adjust | |||
|
|
| |||
|
|
| if necessary. | ||
|
|
|
|
|
|
|
|
|
|
|
|
| Direction |
| • | Wireless model - check reception. See Reception Problems | |
| Wind direction reading is |
| below. | ||
| • | Cabled model - cable may be faulty. | |||
|
| dashed out | |||
|
| If these steps do not reveal the problem, the anemometer may be | |||
|
|
| |||
| Wind |
| faulty. Call technical support for return authorization. | ||
|
|
|
| ||
| Wind direction always says | Usually an ISS problem, especially if outside temperature is dashed | |||
|
| north | out as well. See the ISS manual for troubleshooting information | ||
|
|
|
|
|
|
| Chill | Wind chill reading seems too | Check calibration numbers for temperature. Remember, wind chill | ||
| depends on temperature and wind speed. Make sure they’re work- | ||||
| high or too low | ||||
|
|
| ing. |
|
|
| Heat | Heat Index reading seems | Check calibration numbers for temperature. Remember, the heat in- | ||
| dex depends on temperature and outside humidity. Make sure | ||||
| too high or too low | ||||
|
|
| they’re working. | ||
|
|
|
|
|
|
| Rain | No rain readings | Make sure | ||
| manual. | ||||
|
|
|
|
|
|
|
|
|
|
|
|
| Time | Incorrect times for sunrise | Check your latitude, longitude, time zone, and daylight savings time | ||
| settings. Sunrise and sunset times are calculated from the console | ||||
| and sunset | ||||
|
|
| using all of these settings. |
|
Troubleshooting Reception Problems
While we have tested the Wireless Vantage Pro2 radio extensively, each site and each installation presents its own issues and challenges. Obstruc- tions, particularly metallic ones, will often cut down your station’s recep- tion distance. Be sure to test reception between the console and ISS, in the locations you intend to install them, or before permanently mounting your ISS or other transmitter(s).
38