3. 3 Alarm Setup
Within the Alarm Setup menu, alarm conditions and events, as well as digital motion detection settings are defined.
3. 3. 1 Alarm Outputs
There are four alarm outputs. For each output, define the alarm inputs and conditions.
• Alarm
Select the alarm input(s) to trigger this alarm output.
•Event
Select events to trigger this alarm output.
•Alarm Off
Choose the way the alarm is reset. The alarm can be reset automatically by selecting Automatic and specifying the time in seconds. If it is set to Manual the user must press the STOP button.
The alarm state can be set to either N/O (Normally Open) or N/C (Normally Closed).
3.3. 2 Event
Pre- and
•
Specify the time in 0 ~ 20 seconds.
•Post-Recording Time
Specify the time in 0 ~ 99 seconds.
For each channel, motion detection area and sensitivity can be setup. Press the desired channel button and define the settings.
•Full
Entire video screen is subject to motion detection.
•Area
Motion is detected only in the area specified.
•Sensitivity
Specify the motion sensitivity (1 ~ 30). Higher the value, more sensitive the motion detection is.
•Area Define
Select the motion sensing areas by highlighting the 14 x 14 grid screen.
Use the directional buttons and press the ENTER button.
3. 3. 3 Alarm Name
The alarm inputs can be named. Select the alarm input and enter its name.
3. 3. 4 Alarm Buzzer
If enabled, when an alarm is triggered by the alarm input or motion detection a buzzer will sound. It can automatically clear after a specified time.