Bosch Appliances DVR1EP16, DVR1EP08 Operating the DVR1 Series, Initial Startup, Recording

Page 24
Alarm
Indicator
REC
Record Button

SECTION 6: OPERATING THE DVR1 SERIES

Operating the DVR1 requires general knowledge in three areas:

Recording

Playback

Searching

Certain operating parameters must be set/programmed as part of initial startup of the DVR1. These activities are outlined in the following section.

6.1Initial Startup

On initial power-up of the DVR1, the following settings must be programmed:

Time/Date

Alarms

Password

Please refer to Main Menu Programming, Section 4 for detailed information regarding these functions.

6.2Recording

To begin recording, press REC. The message, RECORD appears briefly in the upper left- hand corner of the primary monitor. The unit always starts recording at the end of the previously recorded data.

Recording continues until one or more of the following occurs:

• Another mode is selected.

• The disk is full (No Overwrite and Overwrite Once modes). See Section 5.3 for details regarding Disk Overwrite modes.

• Video loss is detected. In the event of video loss, VIDEOLOSS will be indicated in the upper left-hand corner of the primary monitor.

1

10:55:45A

 

REC

3

 

 

 

 

2

11/17/00

 

0.2p

4

 

 

 

 

 

1.

Current Time

3.

Record Mode Indicated

 

 

2.

Current Date

4.

Normal Record Speed in

 

 

 

 

 

Pictures per Second

 

Figure 6A - LCD in Record Mode

Normal Recording

The unit records at the normal record speed until an alarm condition is detected. The normal record speed is indicated on the LCD and can be altered using Up/Down Record Speed, or in the menu system.

For information about altering the normal record speed from the menu system, see Section 4.5.

The normal record speed can be altered while the unit is recording. The unit continues recording while the menu system is active.

Alarm Recording

When an alarm condition is detected, the unit automatically switches to the alarm record speed. The alarm condition is indicated in several ways:

REC SPD

Record Speed

Buttons

The word ALARM is displayed on the primary monitor, in the upper left-hand corner of the screen.

• The red LED Alarm Indicator on the front panel of the unit is lit.

• The internal buzzer sounds, if activated via the menu. For information about activating the internal buzzer during alarms, see Section 4.3.

• By an external device connected to the alarm output of the unit (if the unit is configured with an alarm output).

The alarm record speed cannot be changed using Up/Down Record Speed on the front panel; it must be changed via the menu system. See Section 4.5 for details.

The front panel LCD displays the record speed during an alarm condition. The unit returns to the normal record speed once the alarm condition ends.

24

Image 24
Contents DVR1 Series Important Safeguards Safety Precautions Sicherheitshinweise Zasady Bezpieczeństwa Table of Contents Service and Returns Page Introduction to DVR1 Series Digital Video Recorders Guide to This ManualUnpacking Understanding the DVR1 SeriesInstalling the DVR1 Connecting the DVR1Mounting DB-9 Connector on High 12 Guide to the DVR1 Controls DVR1 Front Panel ControlsDVR1 Front Panel Display Main Menu Record Settings Normal Record Speed Date Format Setup Select FormatNavigating with the DVR1 Controls Not highlightedSetting the Time/Date Configuring AlarmsDVR1 Main Menu Programming Overview of the DVR1 Main MenuConfiguring Scheduled Recordings Main Menu Timer SettingsConfiguring the Recording Parameters Main Menu Record SettingsConfiguring On-screen Display Options Main Menu Display SettingsMain Menu Archive Setup Main Menu Archive Setup Selective ArchiveMain Menu Archive Setup Restore From Archive Main Menu Archive Setup Background ArchiveMain Menu Archive Setup Archive Overwrite Mode Main Menu Archive Setup Erase Archive Medium Accessing the Advanced MenuAbout DSR Main Menu About DSRDVR1 Passwords Password BOX Please Enter the PasswordDVR1 Advanced Menu Programming Overview of the DVR1 Advanced Menu Erasing, Deleting, and Recovering Hard Disk Data Using the Auto Delete Feature Overwriting the Hard Disk Invoking Audio RecordingConfiguring Communications Configuring the Multiplexer FormatAdjusting Picture Qualities Locking Out the Front PanelRestoring Factory Defaults Advanced Menu Factory SettingsChanging the Password Advanced Menu Change PasswordOperating the DVR1 Series Initial StartupRecording Playback Message Disk FULL. Recording has StoppedSearch Interface Using CD-Writers ArchivingArchiving Applications Explained Minimum Write Speed Minimum Read Speed Interface SCSI-2Creating a CD-ROM with Video Files Limitations on CD OperationsService and Returns MaintenanceFactory Service All of our products now come with a 3 year warrantyAppendix a Factory Default Settings Function SettingAppendix B Technical Specifications GeneralConnections AUDIO/VIDEOON-SCREEN Video Indicators Part NumbersAppendix C Observation System Quick Install Guide InstallationIntroduction Required Software Version Programming the Observation System monitor Programming the DVR1Select Menu Advanced MENU, then press Enter Remote Viewing ConsiderationsOverview Multiplexer DVR1DVR1 Keyboard Menus DVR1 Controls2 DVR1 Playback Controls Menu Supported Command Sequences Setting the ClockCommand Characters Appendix E RS-232 Remote ProtocolSET Clock Example