Bosch Appliances DVR1EP32A Configuring Communications, Configuring the Multiplexer Format

Page 22

5.7Configuring Communications

Advanced Menu Communications

Use this menu to specify the following (select one only):

Data transfer rate for the RS-232 serial port (select 1200 to 57,600 baud).

Enable or disable Ethernet connection (network address) settings for the unit.

BAUD RATE ETHERNET SETTINGS MODEM SETTINGS

IP address, Subnet Mask, and Gateway. Contact your IT department for details regarding basic network configuration.

POTS Setup (Plain old telephone system): The default modem string (shown below) is for use with Hayes Accura 56k, Diamond Supra Express 56k, and 5686 US Robotics modems in their default conditions. Consult the modem manual before making any changes. It is strongly recommended that the modem initialization string only be modified by a qualified technician.

ETHERNET SETTINGS

ETHERNET

:

DISABLE

IP ADDRESS

:

10. 90.253.000

SUBNET MASK

:

255.255. 0. 0

GATEWAY

:

10. 90. 0. 1

[CANCEL}

 

[OK]

POTS SETUP

MODEM INIT STRING : AT&F1&K3M0E1Q0V1S0=0&R2&C1&D0&H1

[DEFAULT MODEM STRING] [CANCEL] [OK]

@ABCDEFGHIJKLMNOPQRSTUVWXYZ [ \ ] ^

 

 

 

 

NONE

 

 

 

 

KALATEL

5.8 Configuring the Multiplexer Format

 

 

ROBOT

Advanced Menu Multiplexer Format

 

 

DM

The DVR1 Series recorders are compatible with several brands of multiplexers. Use this menu

BOSCH

PELCO

to specify the type of multiplexer connected to the DVR1. Making the correct selection for

 

 

 

 

SANYO

your system configuration ensures proper playback.

 

 

 

 

PHILIP’S

NOTE: If a single camera input is connected to the unit, select NONE.

 

 

 

 

OBSERVATION

NOTE: The list of compatible multiplexers continues to expand. Please see the Bosch Web

SYSTEM

NAVCO

site at www.boschsecuritysystems.com for the most current listing.

 

 

 

 

ATV

 

 

 

 

5.9 Adjusting Picture Qualities

 

 

ATV QSP

Advanced Menu Adjust Picture

 

 

VISTA VLM

Use this menu to specify the Brightness, Contrast, and Saturation of the video input.

 

 

QSI

 

 

 

Adjustments made to the video input affect images being recorded, as well as the current display.

 

 

 

BRIGHTNESS

For each of these parameters, use the Left/Right Arrows to navigate the fields in the

 

 

 

 

CONTRAST

sub-menu. Use the Up/Down Arrows to increase/decrease the setting.

 

 

 

 

SATURATION

 

 

 

 

5.10 Locking Out the Front Panel

 

 

 

 

 

 

Advanced Menu Front Panel Lock

 

 

 

This menu option locks or unlocks the front panel. Exception: the Main Menu will still

 

 

 

 

 

UNLOCK KEYBOARD

display when MENU is pressed.

 

 

LOCK KEYBOARD

 

 

 

 

 

 

 

22

Image 22
Contents DVR1 Series Important Safeguards Safety Precautions Sicherheitshinweise Zasady Bezpieczeństwa Table of Contents Service and Returns Page Unpacking Introduction to DVR1 Series Digital Video RecordersGuide to This Manual Understanding the DVR1 SeriesConnecting the DVR1 Installing the DVR1Mounting DB-9 Connector on High 12 DVR1 Front Panel Controls Guide to the DVR1 ControlsDVR1 Front Panel Display Navigating with the DVR1 Controls Main Menu Record Settings Normal Record SpeedDate Format Setup Select Format Not highlightedDVR1 Main Menu Programming Setting the Time/DateConfiguring Alarms Overview of the DVR1 Main MenuConfiguring the Recording Parameters Configuring Scheduled RecordingsMain Menu Timer Settings Main Menu Record SettingsMain Menu Archive Setup Configuring On-screen Display OptionsMain Menu Display Settings Main Menu Archive Setup Selective ArchiveMain Menu Archive Setup Background Archive Main Menu Archive Setup Restore From ArchiveMain Menu Archive Setup Archive Overwrite Mode About DSR Main Menu Archive Setup Erase Archive Medium Accessing the Advanced Menu Main Menu About DSRDVR1 Advanced Menu Programming DVR1 PasswordsPassword BOX Please Enter the Password Overview of the DVR1 Advanced MenuOverwriting the Hard Disk Erasing, Deleting, and Recovering Hard Disk DataUsing the Auto Delete Feature Invoking Audio RecordingAdjusting Picture Qualities Configuring CommunicationsConfiguring the Multiplexer Format Locking Out the Front PanelChanging the Password Restoring Factory DefaultsAdvanced Menu Factory Settings Advanced Menu Change PasswordInitial Startup Operating the DVR1 SeriesRecording Playback Message Disk FULL. Recording has StoppedSearch Interface Archiving Applications Explained Using CD-WritersArchiving Minimum Write Speed Minimum Read Speed Interface SCSI-2Creating a CD-ROM with Video Files Limitations on CD OperationsFactory Service Service and ReturnsMaintenance All of our products now come with a 3 year warrantyAppendix a Factory Default Settings Function SettingConnections Appendix B Technical SpecificationsGeneral AUDIO/VIDEOON-SCREEN Video Indicators Part NumbersInstallation Appendix C Observation System Quick Install GuideIntroduction Required Software Version Select Menu Advanced MENU, then press Enter Programming the Observation System monitorProgramming the DVR1 Remote Viewing ConsiderationsOverview Multiplexer DVR1DVR1 Keyboard Menus DVR1 Controls2 DVR1 Playback Controls Menu Command Characters Supported Command SequencesSetting the Clock Appendix E RS-232 Remote ProtocolSET Clock Example