SVAT Electronics CVDVR900 user manual Alarm Record Setting

Page 14

OPERATION INSTRUCTION continued

A-5 Alarm Record Setting:

Highlight and select Alarm Record, then press [Enter] for this selection, the sub-menu will shown (as below), then select the required area.

GENERAL SETTINGS

Alarm Record Settings

 

Record Settings

Ch Alarm In_Mode

 

Timer Record

 

Motion Detection

1

On

Close

Alarm_Delay: 005s

Alarm Record

2

Off

Open

Out_Delay: 005s

Channels

3

On

Open

Keep_Delay: 005s

Housings

4

Off

Open

Multi_Ch_Rec: On

Network

Return

 

Multi_Ch_Output: On

Language

 

 

Exit

 

 

 

 

Alarm: "On, Off" are the 2 different status settings available. Use the cursor to select and press [Enter] to confirm this function. While "On" is selected, there will be 16 different task settings for timer setup in each channel (8 different day types, and

2 different period settings available for each type):

Channel 1 Alarm Record Settings

Date

Period 1

Period 2

Everyday

08:00-12:00 14:00-18:00

Mon

08:00-12:00 14:00-18:00

Tue

08:00-12:00 14:00-18:00

Wed

08:00-12:00 14:00-18:00

Thurs

08:00-12:00 14:00-18:00

Fri

08:00-12:00 14:00-18:00

Sat

08:00-12:00 14:00-18:00

Peak

08:00-12:00

14:00-18:00

Return

 

 

Date: Select either "Everyday", "Sun", "Mon", "Tue", "Wed", "Thu", "Fri", "Sat" and "Peak". When "Peak" time is selected, the device does not have the stand-by function.

Period 1 and Period 2: Available to select the start time and end time.

In_Mode: "Open, Close" are the 2 different input modes for alarm signal input. When the alarm system is set to the "Close" option, when open signal starts, the alarm signal is produced. The input mode in here should be set as "Open".

Alarm_Delay: Key in the number key to setup the time delay (range from 0 to 300 seconds) for alarm recording (default setting as 10 seconds).

Out_Delay: Key in the number key to setup the time delay (range from 0 to 300 seconds) for alarm output (default setting as 10 seconds).

Keep_Delay: Key in the number key to setup time delay (range from 0 to 300 seconds) for alarm warning signal (default setting as 10 seconds).

For example: If an alarm is produced at 23:30:50 the device should start the recording from time 23:30:40 since the system per-recording time was set as 10 seconds. The system will release the alarm warning signal. Whole recording depends on the alarm time, per-recording alarm time and alarm warning signal to perform recording

Multi_Ch_Rec: "On, Off" are the 2 different status settings available. Use the cursor to select and press [Enter] to confirm this function. While "On" is selected, there will be 4 multiple channels interface display as shown below:

Image 14
Contents Now you can see Other notices Installation GuidelineInstallation Environment Product FUNCTIONS/ Features Menu Operation Front Panel and key definition LED Indicator status areaFront Panel Playback functionFront Panel Other optionsMPEG4 Alarm connector pin definition Back Panel and connection outletRemote Control Remote Control Key Definition / FunctionOther options System Start up System LoginSystem START-UP/SHUT Down System LogoffOperation Instruction Menu SetupGeneral Parameter Setting Example below is the record default setting Record Parameter SetupTimer Record Setting Conversion Table for Image Quality and Encoding RateMotion Detection Setting Alarm Record Setting Alarm RecordChannel Setting Language Setting Housing SettingNetwork Setting All Record 10ExitInfo Menu Alarm Record Channel Status Alarm LogOperate Log HDD StatusCompact Flash Card Upgrade Operation Instruction Renew setting Copy InformationRecording and Playback Instruction Parameter adjustment Adjustment for Picture Parameter and Sound LevelTechnical Specification Data Playback DVR Hard disk with PC AppendixIDE requirement