Chapter 3 Installing the Chassis
Troubleshooting
Troubleshooting
If trouble occurs during installation, check Table
Table
Problem | Probable Cause | Solution | |
|
|
| |
No power | No power is coming from the | Turn on power. | |
| outlet. |
| |
|
|
| |
| Power cables are loose. | Check and reseat cables. | |
|
|
| |
| Power supply modules are not | Fully engage modules. | |
| engaged. |
| |
|
|
| |
Power alarm | No power is coming from one | Turn on power. | |
| outlet. |
| |
|
|
| |
| One power cable is loose. | Check and reseat cables. | |
|
|
| |
| Power supply fuse is blown. | Check and replace fuse. | |
|
|
| |
Not | Local channel is not online. | Place local channel online. | |
receiving |
|
| |
Check and reseat connectors. | |||
local data | |||
|
| ||
Switch | |||
| |||
|
|
| |
| Connectors are dirty or blown. | Clean or replace connectors. | |
|
|
| |
| Local cables are not properly | Trace and properly connect cables. | |
| seated. |
| |
|
|
| |
| Local link power exceeds budget. | Troubleshoot and retest local link. | |
|
|
| |
| Channel card is not connected. | Connect all required optical fiber cables to the | |
|
| channel card. | |
|
|
| |
| Fiber links are dirty or blown. | Clean or replace fiber cables. | |
|
|
|
| Cisco Metro 1500 Series Hardware Installation Guide |