Cisco Systems 78-10588-03 manual Problem Probable Cause Solution

Page 29

Chapter 3 Installing the Chassis

Troubleshooting

Table 3-2 Troubleshooting Tips (continued)

Problem

Probable Cause

Solution

 

 

 

Not

Fiber-optic connectors are loose.

Check and reseat connectors.

receiving

 

 

Tx-Rx connectors are not matched.

Switch Tx-Rx connectors.

remote data

 

 

Remote cables are not properly

Trace and properly connect cable.

 

 

seated.

 

 

 

 

 

Remote link power exceeds

Troubleshoot and retest remote link.

 

budget.

 

 

 

 

 

Channel card is not connected.

Connect all required optical fiber cables to the

 

 

channel card.

 

 

 

 

Fiber links are dirty or blown.

Clean or replace fiber cables.

 

 

 

Inactive line

Link is not connected.

Connect all required optical fiber cables of the line

is not in

 

to the channel card.

standby

 

 

Remote link power exceeds

Troubleshoot and retest remote link.

mode

budget.

 

 

 

 

 

 

 

Fiber links are dirty or blown.

Clean or replace fiber cables.

 

 

 

No password

A non-supported adapter is being

Use the supplied DB-9 to RJ-45 adapter or an

prompt after

used to connect to the Cisco Metro

adapter that includes DCD/DTR1 flow control and

entering a

1500 series serial port.

RTS/CTS2 flow control.

proper login

 

 

name

 

 

 

 

 

1.DCD/DTR = data carrier detect/data terminal ready

2.RTS/CTS = request to send/clear to send

 

 

Cisco Metro 1500 Series Hardware Installation Guide

 

 

 

 

 

 

78-10588-03

 

 

3-29

 

 

 

Image 29 Contents
Before Installing Installing the ChassisUnpacking and Inspecting the System Mounting the System Maintaining a Network RecordInstalling the System Nemi master Installing the Nemi ModuleInstalling the Chassis Installing the System Demi location Installing the Demi ModuleConnecting Power Fan module Connecting AC PowerFront Panel of the Cisco Metro Installing Terminal Blocks US Version Connecting DC PowerTerminal blocks Holders Power supplyConnecting Wires Fan module Fuse holders DC Power connectorsSelv Application Power Cable Blue Brown Green/yellow Ferrules 48 VDC Application Power CablePower Type Fuse Type No. of Fuses Power Consumption and Power Supply FusesGrounding the Chassis Cleaning the SystemCleaning the Connectors Cleaning the ChassisInstalling the Chassis Cleaning the System Power On/Off Removing the Power Supply ModuleWCM RSM Nemi DMX Power 1 PowerDetermining Power Supply Status Fan module Fuse 11 Rear View of Power Supply ModuleVerifying Connections Running Online TestsMeasuring Channel Outputs and Channel Budgets Installing the Chassis Running Online Tests Problem Probable Cause Solution TroubleshootingProblem Probable Cause Solution Installing the Chassis Troubleshooting