Graco 312787G Replace the Color Change Board, Pin Nos Description Diagnosis

Page 13

Troubleshooting

Table 4: Color Change Board Diagnostics

 

Connector

Board 1 Signal

Board 2 Signal

 

LED

and Pin Nos.

Description

Description

Diagnosis

 

 

 

 

 

D8

n/a

Board OK

Board OK

Blinks (heartbeat) during nor-

 

 

 

 

mal operation.

 

 

 

 

 

D9

n/a

Communication (yellow)

Communication (yellow)

Turns on when board is com-

 

 

 

 

municating with ProMix 2KS.

 

 

 

 

 

D10

J7

Power

Power

Turns on when power is sup-

 

 

 

 

plied to the board.

 

 

 

 

 

D27

J15, 5 & 6

Color 3

Color 16

 

 

 

 

 

 

D28

J14, 3 & 4

Color 1

Color 14

 

 

 

 

 

 

D29

J8, 5 & 6

Color 6

Color 19

 

 

 

 

 

 

D30

J14, 1 & 2

Color 2

Color 15

 

 

 

 

 

 

D31

J8, 3 & 4

Color 7

Color 20

 

 

 

 

 

 

D32

J16, 3 & 4

Catalyst 4

Color 26

 

 

 

 

 

 

D33

J8, 1 & 2

Color 8

Color 21

 

 

 

 

 

 

D34

J9, 5 & 6

Color 9

Color 22

D27 through D46 turn on when

 

 

 

 

D35

J15, 3 & 4

Color 4

Color 17

ProMix 2KS sends a signal to

 

 

 

 

D36

J14, 5 & 6

Solvent (Color)

Color 13

actuate the related solenoid

valve.

 

 

 

 

D37

J10, 5 & 6

Catalyst 2

Color 28

 

 

 

 

 

 

D38

J16, 1 & 2

Catalyst 3

Color 27

 

 

 

 

 

 

D39

J16, 5 & 6

Color 12

Color 25

 

 

 

 

 

 

D41

J15, 1 & 2

Color 5

Color 18

 

 

 

 

 

 

D43

J9, 3 & 4

Color 10

Color 23

 

 

 

 

 

 

D44

J9, 1 & 2

Color 11

Color 24

 

 

 

 

 

 

D45

J10, 3 & 4

Catalyst 1

Color 29

 

 

 

 

 

 

D46

J10, 1 & 2

Solvent (Catalyst)

Color 30

 

 

 

 

 

 

Replace the Color Change Board

1.Remove electrical power from the system. Remove the color change module cover (30).

2.See FIG. 7 on page 12. Note where each cable is connected, then disconnect all cables from the color change board connectors (J7, J8, J9, J10, J11, J14, J15, J16).

3.Remove the six mounting screws (16) and the board (15).

4.Install the new board (15). Reinstall the screws (16).

5.Reconnect the cables to the proper connectors, as noted in step 2.

6.Reinstall the cover (30). Restore electrical power to the system.

312787G

13

Image 13
Contents Color Change Module Kits Important Safety InstructionsRelated Manuals ContentsLow Pressure Kits ModelsHigh Pressure Kits Kit Part No Series DescriptionInstall Color Change Control Module InstallationLocation MountingConnect Module to Fluid Station Board To Install a Second Control ModuleConnect Air Supply to Control Module Intrinsically Safe can Cables Length in ft mInstallation Color Change Board Switch Settings Install Color Valve StacksAccessory Dump Valve Kit Connect Valve Air LinesOne Color Change Board Color Change Board Switch Settings for ProMix 3KS SystemsPositions IG Color Change Board Switch SettingsCause Solution TroubleshootingProblem Cause Solution Color Change Solenoid ValvesReplace the Color Change Board Fuse Replace a SolenoidFuse Description 123690 Fuse 125 mA, intrinsically safe 256172 Color Change Board Color Change Board DiagnosticsPin Nos Description Diagnosis Replace the Color Change BoardSystem Pneumatic Diagram Schematic DiagramsColor Change Module Electrical Schematic Wiring DiagramNon-Hazardous Area System Electrical SchematicBoard Hazardous AreaLow Pressure Color Change Kits PartsHigh Pressure Color Change Kits Color Change Kits Parts Ref. No see Color Change Control ModulesControl Module Part Quantities Description QtyTI12826a Description Qty 277752 2-Color Control Module278095 1 Catalyst/1 Flush Control Module 0 Color Dimensions Control Module Weight, lb kg Technical DataGraco Information Graco Standard Warranty