Connect Module to Fluid Station Board

NOTICE

To avoid damaging circuit board when servicing, wear grounding strap on wrist and ground appropriately.

1.Remove the Fluid Station cover.

2.See FIG. 1. Connect a 5-pin electrical cable (EC)

from the labeled connection port (J11) on the fluid station control board to the color change board. Also see FIG. 2 and FIG. 5.

NOTE: See Table 1 for a list of available cables to con- nect the color change control module and fluid station. Recommended length is 3 ft (1.0 m) or 6 ft (2.0 m).

Table 1: Intrinsically Safe CAN Cables

Part No.

Length in ft (m)

 

 

15U531

2 (0.6)

 

 

15U532

3 (1.0)

 

 

15V205

6 (2.0)

 

 

 

15V206

10

(3.0)

 

 

 

15V207

15

(5.0)

 

 

 

15V208

25

(8.0)

 

 

 

15U533

50

(16.0)

 

 

15V213

100 (32.0)

 

 

 

To Install a Second Control Module

If you are using two color change modules to add colors, connect a 5-pin electrical cable from the first color change board to the second color change board. See FIG. 5.

Installation

J11

(Color Change Module)

FIG. 2: Fluid Station Control Board Connection

Connect Air Supply to Control Module

Connect a 1/4 in. (6 mm) OD tube (13) between the sys- tem’s air manifold (at the bottom rear of the fluid station) and the module air inlet fitting (29). See FIG. 3.

The air supply must be clean and dry. Use a 5 micron fil- ter. Regulate the air pressure to 75-100 psi (0.52-0.70 MPa, 5.25-7.0 bar).

29

FIG. 3: Solenoid Air Connection

TI12824a

312787G

5

Image 5
Contents Color Change Module Kits Important Safety Instructions Related Manuals ContentsLow Pressure Kits ModelsHigh Pressure Kits Kit Part No Series DescriptionInstall Color Change Control Module InstallationLocation MountingConnect Module to Fluid Station Board To Install a Second Control ModuleConnect Air Supply to Control Module Intrinsically Safe can Cables Length in ft mInstallation Color Change Board Switch Settings Install Color Valve StacksAccessory Dump Valve Kit Connect Valve Air LinesOne Color Change Board Color Change Board Switch Settings for ProMix 3KS SystemsPositions IG Color Change Board Switch SettingsCause Solution TroubleshootingProblem Cause Solution Color Change Solenoid ValvesFuse Description 123690 Fuse 125 mA, intrinsically safe Replace a SolenoidReplace the Color Change Board Fuse 256172 Color Change Board Color Change Board DiagnosticsPin Nos Description Diagnosis Replace the Color Change BoardSystem Pneumatic Diagram Schematic DiagramsColor Change Module Electrical Schematic Wiring DiagramNon-Hazardous Area System Electrical SchematicBoard Hazardous AreaHigh Pressure Color Change Kits PartsLow Pressure Color Change Kits Color Change Kits Parts Ref. No see Color Change Control ModulesControl Module Part Quantities Description QtyTI12826a Description Qty 277752 2-Color Control Module278095 1 Catalyst/1 Flush Control Module 0 Color Dimensions Control Module Weight, lb kg Technical DataGraco Information Graco Standard Warranty