Fluke 90100 manual Operation, Rear Panel Familiarization

Page 13

Operation

Introduction 2

Section 2

Operation

2.1 Introduction

This section contains set-up and connection procedures for the Model 90100 TRACKER System in order to measure therapy beam characteristics.

If you want to use build-up to simulate tissue, you can put plates of either "solid water" or acrylic (optional accessories) securely on one or both sides of the Model 35300A Detector. Build-up pegs and retainer rings for securing the plates to the 35300A Detector are optional with the 90100 TRACKER System. See Appendix A for additional information.

It is recommended that the user customize his Model 35360A TRACKER Display prior to its first use as a quality assurance tool. This customization may involve selecting the desired display units, display units conversion factor, temperature units, and pressure units. Procedures for carrying out the customization is covered in Section 5.

2.2 Rear Panel Familiarization

COMPUTER

INTERFACE

RS-232

100-240V 50/60 Hz 50VA

DETECTOR INPUT !

Figure 2-1. Model 35360A TRACKER Display Rear Panel

2-1

Image 13
Contents Tracker System ModelFluke Biomedical Table of Contents Appendix a Using Build-Up Maintenance and ServiceTheory of Operation CustomizationIntroduction General InformationModel FeaturesSafety Terms Before You Start Safety PrecautionsSpecifications Manual AddendaMechanical Specifications Nominal Ion Chamber CharacteristicsRecommended Operation Conditions Ion Chamber Factory CalibrationDisplay Mode Measurements ModeModel 35360A Tracker Display Electrometer / A-D ConverterUnpacking and Inspection High Performance Battery ChargerInterface Cable Detector to Display EnvironmentOptional Equipment Standard System ContentsBlank Rear Panel Familiarization OperationDetector Input Powering the SystemDisplay. Be sure to use the correct end of the cable 3 RS-232 Computer Interface RJ-45 Style Positioning the Model 35300A Detector in the BeamOperation Positioning the Model 353300A Detector in the Beam Front Panel Controls Operation InstructionsReset PowerTest/Detector Units SelectPowering Down the Model 35360A Tracker Display Powering Up the Model 35360A Tracker DisplayUsing the TEST/DETECTOR Button Test/Detector Screen 2 Ion Chamber Calibration Factors Using the Units Select ButtonUsing the Gain Select Button Normal Mode Using the AIR Density ButtonAbsolute Measurements Using the Measure Select Button Normal ModePercent-of-Center Measurements Underranging and Overranging Conditions Battery and Bias Annunciators24. Positions of the Battery and Bias Annunciators Gain Setting ModeAborting the Fpgf Changes Saving the Fpgf ChangesBlank Theory of Operation Hardware Block Diagram of the Model 35360A Tracker Display Power Supply2 300-VOLT Electronic Bias Supply Front Panel SwitchesProcessor VFD DisplayElectrometer Serial Communications PortMultiplexer and A/D Converter Air Density Corrections Model 35300A Ion Chamber DetectorsBasic Operating Equations Basic Operating Quantities Blank Maintenance & Service Problem TroubleshootingNo Display Flowchart Low battery Yes Annuciator displayed? Low Battery Indication at the Display35360A Tracker Bias Error LoBias or HiBias Indication at the DisplayLeakage Flowchart Dose Rate Measurement Zero Problem Flowchart Line Fuse ReplacementIf fuses continue to blow return instrument for repair Cleaning the Instrument Interface Connector CleaningReplaceable Parts Information Recalibration & Repair Information / Technical Assistance Replaceable Parts ListCustomization Connection to the Computer Make a Working DiskStarting the Customization Software Screen FormatsDisplay Customization Items Screen Appearance F2 Edit Item Editing F1 Help On-Line Help for using the Customization softwareF6 Print Report Printing F10 ExitDefinitions Charge Gain QG Setting the Electrometer Gains and OffsetsCurrent Gain, Current Zero IG and ADZ Ion Chamber Calibration Factor IccfElectrometer Charge Gains QG Electrometer Current Gain IGUsage Examples Changing the Power Down IntervalChanging the ION Chamber Calibration Factor Units Input Errors ErrorsBuild-Up, Peg, and Retainer Kit Options Using Build-UpNominal Number of build-up Solid Water Appendix Fluke Biomedical