AMX MAX-CSE, MAX-CSD 10 manual Setting up a Modero Panel to Receive and Display a Stream

Page 70

Displaying Stream Content

media content. If the network can only handle a throughput of 4 Mbps from the encoder, it is recommended that you use something less than or equal to the High Quality encoder profile.

To receive and display content via a third-party media player (such as the VLC media player):

Verify you are using the latest VLC Player application available at:

http://www.videolan.org/vlc/.

UDP transmission of a stream only requires one instance of the VLC Player to display the combined A/V content.

Note that if you are going to try to stream both audio and video to a target computer as separate streams, you will need to open two separate instances of this same application.

One window will display the video portion of the stream (provided by the Target Port field on the Streaming Profiles page), whereas the second window provides the audio portion of the stream (provided by the Target Audio Port field on the Streaming Profiles page).

Obtain the IP Address of the target computer by using the ipconfig command. This process is described in greater detail later in this section.

Setting up a Modero Panel to Receive and Display a Stream

The MAX-CSE must first be prepared to stream to the target Modero panel prior to creating the necessary TPDesign4 panel pages (later be uploaded to the panel).

Obtaining the IP Address of the target panel

1.Press the grey Front Setup Access button for 3 seconds to open the Setup page (FIG. 40).

Connection Status

Red Connection Status icon -

indicates no connection to a Master

Green Connection Status icon -

indicates communication to a Master

FIG. 40 Setup page

2.Press the Protected Setup button (located on the lower-left of the panel page) to open the Protected Setup page and display an on-screen keypad.

3.Enter 1988 into the Keypad’s password field and press Done when finished.

4.Press the System Settings button (located on the Protected Setup page) to open the System Settings page and obtain the IP information from the IP Address field (FIG. 41).

64

MAX-CSE/MAX-CSD10 Operation/Reference Guide

Image 70
Contents MAX-CSE/MAX-CSD10 AMX Limited Warranty and Disclaimer Table of Contents MAX-CSD10 Web Interface Configuration and Firmware Update Page Overview MAX Encoder FeaturesMAX-CSE Video Encoder MAX-CSE FG2178-70 ComponentsMAX-CSE Product Specifications MAX-CSE SpecificationsWhile in IR mode Sensing for IR ports MAX-CSD10 Video Decoder MAX-CSD10 Product SpecificationsMAX Decoder Features MAX-CSD10 FG2178-72 ComponentsMAX-CSD10 FG2178-72 Specifications AACMAX-CSD10 Specifications Page Wiring Guidelines Direct Power MAX-CSE and MAX-CSD10 InstallationMAX-CSE and MAX-CSD10 Connections and Wiring Port Assignments and FunctionalityWiring a power connection Wiring length guidelinesPreparing captive wires Wiring Guidelines Indirect Power via PoEPoE Special wiring instructions CSE MAX-CSEWiring the MAX-CSE connectors and cables VDC power SupplySignals Connection Pairing Color Ethernet/RJ-45 Port Connections and WiringEthernet RJ-45 Pinouts and Signals MICDB9 Device Port Connections and Wiring Power over Ethernet PoE wiringEthernet LEDs Input/Output I/O Port Connections and Wiring IR/Serial Port Connections and WiringRS-232/422/485 Device Port Wiring Specifications Port Wiring Specifications Wiring the MAX-CSD10 connectors and cablesPin Signal Function Installing Into an Equipment Rack Page Security Terms Default Security ConfigurationMAX-CSE Web Interface Security TermsAdministrator account Default Security Configuration case-sensitiveCommunicating with the unit via the browser-based UI Feature Description Navigation Bar MAX-CSE User Interface Overview and FeaturesUser Interface Features Browser-based UI Application OverviewFeature Description Administration Page FeaturesStream Status Feature Description Resources AdministrationAdministration Example Computer CourseMode Changing the Program DescriptionUpload Firmware Click Upload a File Click Reboot done. Upload a File Upgrading New FirmwareStream Profiles Stream ProfilesFeature Description Encoder Profile Stream Profiles Page FeaturesVideo Resolution AudioSVCD, MP3 StreamSAP Settings Obtaining the IP information for a target ModeroEncoder Profiles and Parameters Changing the Encoder ProfileVCR Set up Page Features Set upFeature Description Video NetLinx Settings Changing Video and Audio SettingsNetLinx Settings Page Features Feature Description NetLinx MasterIP Settings Changing the NetLinx Master ConnectionFeature Description IP Address Changing the IP SettingsIP Settings Page Features DNS AddressFeature Description User User Page FeaturesUser Changing User Settings MAX-CSD10 Web Interface MAX-CSD10 User Interface Overview and FeaturesFeature Description Browser Address field Navigation frameLogoff Feature Description Stream Status frameActive Page frame Communicating With The Unit Via the Browser-based UI Updating FirmwareStream Selector Page Features Stream SelectorStream Set-up Page Features Stream Set-upSetting up an SAP stream configuration Changing the stream configurationSetting up an Rtsp stream configuration Setting up a Manual stream configuration Stream Configuration Page Manual ModeAudio/Video Audio/Video Page FeaturesNetLinx Page Features NetLinxTo make changes to the IP Settings To change the User Login Settings User Page DetailsConfiguring Communication Reading the Front Panel LCDConfiguring the MAX Communication Parameters Obtaining the unit’s initial Dhcp AddressSave login profile selection box Communicating with the Target Master via an IP Assigning Master Communication Settings and TCP/IP Settings Associating the MAX unit to a Target Master Associating a MAX-CSE to a Target MasterStudio Online Tree tab showing the communicating MAX unit Changing the MAX-CSE device number via the UI Changing the MAX’s Device NumberAssociating a MAX-CSD10 Unit to a Target Master Changing the MAX-CSE device number via StudioUsing the ID button to change the MAX-CSE’s Device Value Recommended NetLinx Device numbersChanging the MAX-CSD10 device number via the UI MAX vs. NetLinx Master Functional Overlap Configuration and Firmware UpdateBefore You Begin Verifying the MAX’s current version of Firmware via the UIVerifying the MAX’s current version of Firmware via Studio Upgrading MAX FirmwareUpgrading MAX-CSE Firmware via the UI Upgrading MAX-CSD10 Firmware via the UI Upgrading the MAX’s Firmware via NetLinx StudioClick Close once the download process is complete Displaying Stream Content Requirements for Receiving Streamed ContentSetting up a Modero Panel to Receive and Display a Stream Obtaining the IP Address of the target panelConfiguring the MAX-CSE for communication System SettingsStream Profiles Configuring the MAX-CSE audio/video inputs V SetupSetting up a streaming page within TPDesign4 Rtpmpeg#//IP Address of MAX-CSETarget Video Port Video Adjustment page showing default values Establishing the final connection between the two unitsConfigure the MAX-CSE for communication to a computer Setting up a Computer to Receive and Display a StreamObtaining the IP Address of the target computer Displaying Stream Content RTP Video Stream Component RTP Audio Stream Component Page Port Assignments NetLinx ProgrammingDevicePortSystem DPS Port/DescriptionCommand Description MAX-CSE Streaming Commands PortMAX-CSE Streaming SendCommands GET AsourceGET Gain GET SAP IP ModeGET Format GET SAPGET Session List GET Session InfoGET Stream Status GET Video GET URLGET Video Port Status SET Asource GET VsourcePlay SET AudioSET Gain SET SAP IP ModeSET Format SET SAPSET URL Sendcommand ENCODER,SET Video MPEG2 D1 6000 CBRSET Video SET Vsource MAX-CSD Streaming Commands PortMAX-CSD Streaming SendCommands StopGET Rtsp Server GET Control ModeGET Session Cursor Sendcommand DECODER, GET Session Info 2 MEDIA1 Sendcommand DECODER, GET Session Info 1 TitleSendcommand DECODER, GET Session Info 2 Title Sendcommand DECODER, GET Session Info 2 MEDIA2Sendcommand DECODER, Play Sendcommand DECODER,GET URLSendcommand DECODER,GET Video Sendcommand DECODER,SET Audio MP3Sendcommand DECODER,SET Format PAL SET Control ModeSendcommand DECODER, SET Control Mode SAP Sendcommand DECODER, SET SAP IP Mode ALTSendcommand DECODER,SET Video MPEG2 Sendcommand DECODER, SET Sesson CursorSendcommand DECODER,SET URL UDP 224.0.0.1 SET Session CursorRS-232/422/485 SendCommands Port RS-232/422/485 SendCommandsCtspsh OFF ChardmCtspsh GET BaudSET Baud RxoffRxon Tset BaudTxclr RS232/422/485 Ports ChannelsRS232/422/485 Ports Channels XoffRS-232/422/485 SendString Escape Sequences Port RS-232/422/485 SendString Escape SequencesIR / Serial Ports Channels IR/Serial Port Port 3 CommandsIR/Serial SendCommands IR / Serial Ports ChannelsCtof GET ModeCton POF IroffPOD PONPton PtofSET IO Link Sendcommand IR1, SP,25 SET ModeSendcommand IR1,SET Mode IR Short cable length 10 feetSendcommand IR1,XCH Sendcommand DEV,XCHM extended channel modeSendcommand IR1,XCHM XchmIR RX Port Channels Port Port Commands PortSend Commands GET InputBACKLIGHT-0 LCD Commands PortBacklight BACKLIGHT-50Page Programming MAX-CSE/MAX-CSD10 Operation/Reference Guide 103 It’s Your World Take Control
Related manuals
Manual 2 pages 62.62 Kb Manual 116 pages 15.94 Kb

MAX-CSD 10, MAX-CSE specifications

The AMX MAX-CSE and MAX-CSD 10 are advanced multimedia presentation systems designed to enhance communication and collaboration in various professional environments. These devices are tailored for modern conference rooms, educational institutions, and corporate settings, providing seamless integration of audio-visual technology to facilitate effective presentations and meetings.

One of the standout features of the MAX-CSE and MAX-CSD 10 is their sophisticated audio and video processing capabilities. The MAX-CSE serves as a central management hub, supporting high-definition video outputs and multiple input sources, including HDMI, VGA, and wireless connectivity options. This versatility ensures that users can connect a wide array of devices—laptops, tablets, and smartphones—without hassle and quickly switch between them during presentations.

The MAX-CSD 10 complements the MAX-CSE as a dedicated audio unit equipped with powerful amplification and precise tuning. It delivers clear and balanced sound, even in larger rooms, ensuring that every participant can engage fully, regardless of their location in the space. With features like echo cancellation and noise reduction technology, the MAX-CSD 10 enhances voice clarity, making it ideal for video conferencing and webinars.

An important characteristic of the AMX MAX series is their user-friendly interface. The systems are designed for intuitive operation, enabling users to control various settings with ease, whether they are tech-savvy or not. The touch panel interface can be customized to meet specific needs, allowing quick access to essential functions such as lighting, video routing, and audio control.

In terms of connectivity, both systems are equipped with robust network capability, allowing integration with existing IT infrastructure. This feature ensures that users can manage and control the systems remotely through a web interface or compatible applications, enhancing productivity and easing the overall user experience.

Robust security measures are also a significant aspect of the AMX MAX-CSE and MAX-CSD 10 systems. They are designed with advanced encryption and user authentication protocols, ensuring that sensitive data remains protected during presentations and meetings.

In conclusion, the AMX MAX-CSE and MAX-CSD 10 multimedia presentation systems stand out in the market due to their superior audio and video quality, user-friendly features, and extensive connectivity options. They are ideal solutions for professionals seeking to leverage technology for more productive and engaging communication.