AMX MAX-CSE, MAX-CSD 10 manual NetLinx Settings Page Features, Feature Description NetLinx Master

Page 40

MAX-CSE Web Interface

The following table lists the NetLinx Settings page features that an administrator or other authorized user can configure.

NetLinx Settings Page Features

Feature

Description

 

 

NetLinx Master:

This section allows the user/administrator to define the communication and encryption

 

parameters of the target Master.

• Connection

 

• A status field which indicates whether a Master has been detected and

 

communicating with the MAX-CSE.

 

• During the initial setup, this field reads Not Connected.

 

• After a successful connection to a target Master, this fields reads Connected.

• Mode

 

• A drop-down list from which the user can choose which NetLinx connection Mode

 

will be used to communicate with the target Master.

 

• Available modes: Listen, Auto (default), URL

 

Listen sets the MAX unit to "listen" for broadcasts from the Master. In this system,

 

the MAX unit acts as a "Server" (in that Clients attach to it) and the Master acts as a

 

"Client".

 

Auto is used to instruct the MAX unit to search for a Master that both uses the same

 

System Number (assigned within this page’s System Number field) and resides on

 

the same Subnet as itself. In this case, the Master has its UDP feature enabled.

 

URL is the address that defines the route to a file on the Web or any other Internet

 

facility. This setting is used when the IP Address of the target NetLinx Master is

 

known. In this system, the MAX unit acts as a "Client" and the Master acts as a

 

Server (in that Clients attach to it). In URL mode, you can only enter the IP/URL of

 

the target Master. The System Number is 0 (for an unknown System Number) and

 

the Master Port Number is defaulted to 1319.

• System Number

 

Allows a user to enter a system number.

 

Default value is 3701.

 

• Only in the Auto Mode will the System field be user-definable.

• Device Number

 

Allows a user to enter a current device value (non-duplicated). You must use a value

 

which is not currently being used by another device currently communicating with the

 

target Master.

 

• Within NetLinx Studio, use the Online Tree tab to review what device values are

 

already being used.

 

• Default value is 32001.

 

 

• Master IP/URL

Allows a user to enter the IP Address or URL used by the target Master.

 

Note: This is the same IP Address used by NetLinx Studio to communicate with the

 

Master.

 

• Target Master IP Address must be in IPv4 dot notation (ex: X.X.X.X).

• Master Port Number

 

Allows the user to enter the port number used by the NetLinx Master.

 

• Default value is 1319.

• Encryption

 

Based on the Master’s security status.

 

• Default value is Disabled (fields are greyed-out).

 

• These radio boxes either enable or disable data encryption of the data transferred

 

between the Master and the MAX over the ICSP connection. Note that this is

 

optional. If this is enabled, this setting requires more processor cycles to maintain.

 

• This selection determines if a username and password is required prior to

 

communication between the MAX unit and the target NetLinx Master via an ICSP

 

connection using a transport method such as TCP/IP or UDP/IP.

• Username/Password

 

If the target Master has been previously secured, enter an alpha-numeric string (into

 

each field) which conforms to a pre-configured user profile on the Master. This profile

 

must have sufficient access rights.

 

Requiring the encryption of any data being transmitted or received via an ICSP con-

 

nection (via the previous radio box) also mandates that a valid username and pass-

 

word be provided within the Username and Password fields.

 

 

34

MAX-CSE/MAX-CSD10 Operation/Reference Guide

Image 40
Contents MAX-CSE/MAX-CSD10 AMX Limited Warranty and Disclaimer Table of Contents MAX-CSD10 Web Interface Configuration and Firmware Update Page MAX Encoder Features MAX-CSE Video EncoderOverview MAX-CSE FG2178-70 ComponentsMAX-CSE Product Specifications MAX-CSE SpecificationsWhile in IR mode Sensing for IR ports MAX-CSD10 Product Specifications MAX Decoder FeaturesMAX-CSD10 Video Decoder MAX-CSD10 FG2178-72 ComponentsMAX-CSD10 FG2178-72 Specifications AACMAX-CSD10 Specifications Page MAX-CSE and MAX-CSD10 Installation MAX-CSE and MAX-CSD10 Connections and WiringWiring Guidelines Direct Power Port Assignments and FunctionalityWiring length guidelines Preparing captive wiresWiring a power connection Wiring Guidelines Indirect Power via PoEPoE Special wiring instructions CSE MAX-CSEWiring the MAX-CSE connectors and cables VDC power SupplyEthernet/RJ-45 Port Connections and Wiring Ethernet RJ-45 Pinouts and SignalsSignals Connection Pairing Color MICDB9 Device Port Connections and Wiring Power over Ethernet PoE wiringEthernet LEDs Input/Output I/O Port Connections and Wiring IR/Serial Port Connections and WiringRS-232/422/485 Device Port Wiring Specifications Port Wiring Specifications Wiring the MAX-CSD10 connectors and cablesPin Signal Function Installing Into an Equipment Rack Page Default Security Configuration MAX-CSE Web InterfaceSecurity Terms Security TermsAdministrator account Default Security Configuration case-sensitiveCommunicating with the unit via the browser-based UI MAX-CSE User Interface Overview and Features User Interface FeaturesFeature Description Navigation Bar Browser-based UI Application OverviewFeature Description Administration Page FeaturesStream Status Administration AdministrationFeature Description Resources Example Computer CourseMode Changing the Program DescriptionUpload Firmware Click Upload a File Click Reboot done. Upload a File Upgrading New FirmwareStream Profiles Stream ProfilesFeature Description Encoder Profile Stream Profiles Page FeaturesVideo Resolution AudioSVCD, MP3 StreamSAP Settings Obtaining the IP information for a target ModeroEncoder Profiles and Parameters Changing the Encoder ProfileVCR Set up Page Features Set upFeature Description Video NetLinx Settings Changing Video and Audio SettingsNetLinx Settings Page Features Feature Description NetLinx MasterIP Settings Changing the NetLinx Master ConnectionChanging the IP Settings IP Settings Page FeaturesFeature Description IP Address DNS AddressFeature Description User User Page FeaturesUser Changing User Settings MAX-CSD10 User Interface Overview and Features Feature Description Browser Address fieldMAX-CSD10 Web Interface Navigation frameLogoff Feature Description Stream Status frameActive Page frame Communicating With The Unit Via the Browser-based UI Updating FirmwareStream Selector Page Features Stream SelectorStream Set-up Page Features Stream Set-upSetting up an SAP stream configuration Changing the stream configurationSetting up an Rtsp stream configuration Setting up a Manual stream configuration Stream Configuration Page Manual ModeAudio/Video Page Features NetLinx Page FeaturesAudio/Video NetLinxTo make changes to the IP Settings To change the User Login Settings User Page DetailsConfiguring Communication Reading the Front Panel LCDConfiguring the MAX Communication Parameters Obtaining the unit’s initial Dhcp AddressSave login profile selection box Communicating with the Target Master via an IP Assigning Master Communication Settings and TCP/IP Settings Associating the MAX unit to a Target Master Associating a MAX-CSE to a Target MasterStudio Online Tree tab showing the communicating MAX unit Changing the MAX’s Device Number Associating a MAX-CSD10 Unit to a Target MasterChanging the MAX-CSE device number via the UI Changing the MAX-CSE device number via StudioUsing the ID button to change the MAX-CSE’s Device Value Recommended NetLinx Device numbersChanging the MAX-CSD10 device number via the UI Configuration and Firmware Update Before You BeginMAX vs. NetLinx Master Functional Overlap Verifying the MAX’s current version of Firmware via the UIVerifying the MAX’s current version of Firmware via Studio Upgrading MAX FirmwareUpgrading MAX-CSE Firmware via the UI Upgrading MAX-CSD10 Firmware via the UI Upgrading the MAX’s Firmware via NetLinx StudioClick Close once the download process is complete Displaying Stream Content Requirements for Receiving Streamed ContentSetting up a Modero Panel to Receive and Display a Stream Obtaining the IP Address of the target panelConfiguring the MAX-CSE for communication System SettingsStream Profiles Configuring the MAX-CSE audio/video inputs V SetupSetting up a streaming page within TPDesign4 Rtpmpeg#//IP Address of MAX-CSETarget Video Port Video Adjustment page showing default values Establishing the final connection between the two unitsConfigure the MAX-CSE for communication to a computer Setting up a Computer to Receive and Display a StreamObtaining the IP Address of the target computer Displaying Stream Content RTP Video Stream Component RTP Audio Stream Component Page NetLinx Programming DevicePortSystem DPSPort Assignments Port/DescriptionMAX-CSE Streaming Commands Port MAX-CSE Streaming SendCommandsCommand Description GET AsourceGET SAP IP Mode GET FormatGET Gain GET SAPGET Session List GET Session InfoGET Stream Status GET Video GET URLGET Video Port Status GET Vsource PlaySET Asource SET AudioSET SAP IP Mode SET FormatSET Gain SET SAPSET URL Sendcommand ENCODER,SET Video MPEG2 D1 6000 CBRSET Video MAX-CSD Streaming Commands Port MAX-CSD Streaming SendCommandsSET Vsource StopGET Rtsp Server GET Control ModeGET Session Cursor Sendcommand DECODER, GET Session Info 1 Title Sendcommand DECODER, GET Session Info 2 TitleSendcommand DECODER, GET Session Info 2 MEDIA1 Sendcommand DECODER, GET Session Info 2 MEDIA2Sendcommand DECODER,GET URL Sendcommand DECODER,GET VideoSendcommand DECODER, Play Sendcommand DECODER,SET Audio MP3SET Control Mode Sendcommand DECODER, SET Control Mode SAPSendcommand DECODER,SET Format PAL Sendcommand DECODER, SET SAP IP Mode ALTSendcommand DECODER, SET Sesson Cursor Sendcommand DECODER,SET URL UDP 224.0.0.1Sendcommand DECODER,SET Video MPEG2 SET Session CursorRS-232/422/485 SendCommands Port RS-232/422/485 SendCommandsChardm CtspshCtspsh OFF GET BaudRxoff RxonSET Baud Tset BaudRS232/422/485 Ports Channels RS232/422/485 Ports ChannelsTxclr XoffRS-232/422/485 SendString Escape Sequences Port RS-232/422/485 SendString Escape SequencesIR/Serial Port Port 3 Commands IR/Serial SendCommandsIR / Serial Ports Channels IR / Serial Ports ChannelsCtof GET ModeCton Iroff PODPOF PONPton PtofSET IO Link SET Mode Sendcommand IR1,SET Mode IRSendcommand IR1, SP,25 Short cable length 10 feetSendcommand DEV,XCHM extended channel mode Sendcommand IR1,XCHMSendcommand IR1,XCH XchmPort Commands Port Send CommandsIR RX Port Channels Port GET InputLCD Commands Port BacklightBACKLIGHT-0 BACKLIGHT-50Page Programming MAX-CSE/MAX-CSD10 Operation/Reference Guide 103 It’s Your World Take Control
Related manuals
Manual 2 pages 62.62 Kb Manual 116 pages 15.94 Kb

MAX-CSD 10, MAX-CSE specifications

The AMX MAX-CSE and MAX-CSD 10 are advanced multimedia presentation systems designed to enhance communication and collaboration in various professional environments. These devices are tailored for modern conference rooms, educational institutions, and corporate settings, providing seamless integration of audio-visual technology to facilitate effective presentations and meetings.

One of the standout features of the MAX-CSE and MAX-CSD 10 is their sophisticated audio and video processing capabilities. The MAX-CSE serves as a central management hub, supporting high-definition video outputs and multiple input sources, including HDMI, VGA, and wireless connectivity options. This versatility ensures that users can connect a wide array of devices—laptops, tablets, and smartphones—without hassle and quickly switch between them during presentations.

The MAX-CSD 10 complements the MAX-CSE as a dedicated audio unit equipped with powerful amplification and precise tuning. It delivers clear and balanced sound, even in larger rooms, ensuring that every participant can engage fully, regardless of their location in the space. With features like echo cancellation and noise reduction technology, the MAX-CSD 10 enhances voice clarity, making it ideal for video conferencing and webinars.

An important characteristic of the AMX MAX series is their user-friendly interface. The systems are designed for intuitive operation, enabling users to control various settings with ease, whether they are tech-savvy or not. The touch panel interface can be customized to meet specific needs, allowing quick access to essential functions such as lighting, video routing, and audio control.

In terms of connectivity, both systems are equipped with robust network capability, allowing integration with existing IT infrastructure. This feature ensures that users can manage and control the systems remotely through a web interface or compatible applications, enhancing productivity and easing the overall user experience.

Robust security measures are also a significant aspect of the AMX MAX-CSE and MAX-CSD 10 systems. They are designed with advanced encryption and user authentication protocols, ensuring that sensitive data remains protected during presentations and meetings.

In conclusion, the AMX MAX-CSE and MAX-CSD 10 multimedia presentation systems stand out in the market due to their superior audio and video quality, user-friendly features, and extensive connectivity options. They are ideal solutions for professionals seeking to leverage technology for more productive and engaging communication.