AMX MAX-CSE, MAX-CSD 10 manual Setting up a streaming page within TPDesign4

Page 74

Displaying Stream Content

4.If you are feeding a microphone audio signal into the rear MAX-CSE microphone connector, you could use the Microphone Gain field to enter an audio level (0 - 99) associated with the gain used by the rear microphone input.

At any time, the user can choose to mute the incoming microphone signal by either toggling the state of the Microphone icon located at the top of the page or entering a value of zero into the Mic Gain field.

5.Click the Apply button to save the encoding profiles to the MAX-CSE.

Setting up a streaming page within TPDesign4

1.Launch TPDesign4 (default location is Start > Programs > AMX Control Disc > TPDesign4 > TPDesign4). Refer to the TPDesign4 Instruction Manual for more detailed instructions of these procedures.

2.From the menu bar, select File > New (or click the New Project toolbar button).

3.From within the Step 1 dialog, enter a generic Job name and use the Panel Type drop-down arrow to choose a VG-Series panel (1200VG, 1500VG, or 1700GVG).

For the purpose of these procedures, we’ve chosen to use a Job Name of Test and selected an NXD-1700VGtouch panel.

4.Fill in the fields within the remaining New Project Wizard dialogs and click Next at the end of each dialog to proceed final dialog.

5.Click the Finish button in the last dialog to close the wizard and proceed to the first generic page which is ready for you to start adding pages, popup pages, and buttons.

6.Add a new page to the project by selecting Page > Add Page (or click the toolbar icon) which opens the Add Page dialog, where you can then enter a descriptive name for the new page in the Name field such as Full Screen Video (UDP).

Note that although a page cannot directly be setup to display a video stream, a user can create a full-screen button on that same page which can be configured to fill its contents with a video stream.

7.Press the Button Draw Tool (CTRL+U) to draw a square button.

8.Press the Selection Tool (CTRL+L) to grab the new button and stretch it to fill a desired area of the page. For our procedures, we stretched the new button to fill the entire available are of the newly created page (FIG. 44).

9.With the button currently selected and active, navigate to the left section of the Workspace and find the Button Properties Control window (FIG. 44).

10.Click the States tab of the Button Properties Control window to show a list of all states associated with the selected button. Each state represented in the States tab is a collapsed folder containing the state properties for that particular state (On/Off/All).

11.Double-click the All States + symbol to expand this folder (FIG. 45) and locate the Video Fill field.

12.Use the Video Fill drop-down arrow to select the Streaming Video option (A in FIG. 45).

13.Within the newly added Streaming Source field, enter the Transport Protocol, IP Address of the MAX-CSE, and Target Video Port (B in FIG. 45).

When using a UDP Transport Protocol, enter the following into the Streaming Source field: udp://IP Address of MAX-CSE:Target Video Port set on the UI page.

68

MAX-CSE/MAX-CSD10 Operation/Reference Guide

Image 74
Contents MAX-CSE/MAX-CSD10 AMX Limited Warranty and Disclaimer Table of Contents MAX-CSD10 Web Interface Configuration and Firmware Update Page Overview MAX Encoder FeaturesMAX-CSE Video Encoder MAX-CSE FG2178-70 ComponentsMAX-CSE Product Specifications MAX-CSE SpecificationsWhile in IR mode Sensing for IR ports MAX-CSD10 Video Decoder MAX-CSD10 Product SpecificationsMAX Decoder Features MAX-CSD10 FG2178-72 ComponentsMAX-CSD10 FG2178-72 Specifications AACMAX-CSD10 Specifications Page Wiring Guidelines Direct Power MAX-CSE and MAX-CSD10 InstallationMAX-CSE and MAX-CSD10 Connections and Wiring Port Assignments and FunctionalityWiring a power connection Wiring length guidelinesPreparing captive wires Wiring Guidelines Indirect Power via PoEPoE Special wiring instructions CSE MAX-CSEWiring the MAX-CSE connectors and cables VDC power SupplySignals Connection Pairing Color Ethernet/RJ-45 Port Connections and WiringEthernet RJ-45 Pinouts and Signals MICEthernet LEDs Power over Ethernet PoE wiringDB9 Device Port Connections and Wiring RS-232/422/485 Device Port Wiring Specifications IR/Serial Port Connections and WiringInput/Output I/O Port Connections and Wiring Pin Signal Function Wiring the MAX-CSD10 connectors and cablesPort Wiring Specifications Installing Into an Equipment Rack Page Security Terms Default Security ConfigurationMAX-CSE Web Interface Security TermsCommunicating with the unit via the browser-based UI Default Security Configuration case-sensitiveAdministrator account Feature Description Navigation Bar MAX-CSE User Interface Overview and FeaturesUser Interface Features Browser-based UI Application OverviewStream Status Administration Page FeaturesFeature Description Feature Description Resources AdministrationAdministration Example Computer CourseUpload Firmware Changing the Program DescriptionMode Click Upload a File Click Reboot done. Upload a File Upgrading New FirmwareStream Profiles Stream ProfilesVideo Stream Profiles Page FeaturesFeature Description Encoder Profile Resolution AudioSVCD, MP3 StreamSAP Settings Obtaining the IP information for a target ModeroVCR Changing the Encoder ProfileEncoder Profiles and Parameters Feature Description Video Set upSet up Page Features NetLinx Settings Changing Video and Audio SettingsNetLinx Settings Page Features Feature Description NetLinx MasterIP Settings Changing the NetLinx Master ConnectionFeature Description IP Address Changing the IP SettingsIP Settings Page Features DNS AddressUser User Page FeaturesFeature Description User Changing User Settings MAX-CSD10 Web Interface MAX-CSD10 User Interface Overview and FeaturesFeature Description Browser Address field Navigation frameActive Page frame Feature Description Stream Status frameLogoff Communicating With The Unit Via the Browser-based UI Updating FirmwareStream Selector Page Features Stream SelectorStream Set-up Page Features Stream Set-upSetting up an Rtsp stream configuration Changing the stream configurationSetting up an SAP stream configuration Setting up a Manual stream configuration Stream Configuration Page Manual ModeAudio/Video Audio/Video Page FeaturesNetLinx Page Features NetLinxTo make changes to the IP Settings To change the User Login Settings User Page DetailsConfiguring Communication Reading the Front Panel LCDConfiguring the MAX Communication Parameters Obtaining the unit’s initial Dhcp AddressSave login profile selection box Communicating with the Target Master via an IP Assigning Master Communication Settings and TCP/IP Settings Associating the MAX unit to a Target Master Associating a MAX-CSE to a Target MasterStudio Online Tree tab showing the communicating MAX unit Changing the MAX-CSE device number via the UI Changing the MAX’s Device NumberAssociating a MAX-CSD10 Unit to a Target Master Changing the MAX-CSE device number via StudioUsing the ID button to change the MAX-CSE’s Device Value Recommended NetLinx Device numbersChanging the MAX-CSD10 device number via the UI MAX vs. NetLinx Master Functional Overlap Configuration and Firmware UpdateBefore You Begin Verifying the MAX’s current version of Firmware via the UIUpgrading MAX-CSE Firmware via the UI Upgrading MAX FirmwareVerifying the MAX’s current version of Firmware via Studio Upgrading MAX-CSD10 Firmware via the UI Upgrading the MAX’s Firmware via NetLinx StudioClick Close once the download process is complete Displaying Stream Content Requirements for Receiving Streamed ContentSetting up a Modero Panel to Receive and Display a Stream Obtaining the IP Address of the target panelConfiguring the MAX-CSE for communication System SettingsStream Profiles Configuring the MAX-CSE audio/video inputs V SetupSetting up a streaming page within TPDesign4 Rtpmpeg#//IP Address of MAX-CSETarget Video Port Video Adjustment page showing default values Establishing the final connection between the two unitsObtaining the IP Address of the target computer Setting up a Computer to Receive and Display a StreamConfigure the MAX-CSE for communication to a computer Displaying Stream Content RTP Video Stream Component RTP Audio Stream Component Page Port Assignments NetLinx ProgrammingDevicePortSystem DPS Port/DescriptionCommand Description MAX-CSE Streaming Commands PortMAX-CSE Streaming SendCommands GET AsourceGET Gain GET SAP IP ModeGET Format GET SAPGET Stream Status GET Session InfoGET Session List GET Video Port Status GET URLGET Video SET Asource GET VsourcePlay SET AudioSET Gain SET SAP IP ModeSET Format SET SAPSET Video Sendcommand ENCODER,SET Video MPEG2 D1 6000 CBRSET URL SET Vsource MAX-CSD Streaming Commands PortMAX-CSD Streaming SendCommands StopGET Session Cursor GET Control ModeGET Rtsp Server Sendcommand DECODER, GET Session Info 2 MEDIA1 Sendcommand DECODER, GET Session Info 1 TitleSendcommand DECODER, GET Session Info 2 Title Sendcommand DECODER, GET Session Info 2 MEDIA2Sendcommand DECODER, Play Sendcommand DECODER,GET URLSendcommand DECODER,GET Video Sendcommand DECODER,SET Audio MP3Sendcommand DECODER,SET Format PAL SET Control ModeSendcommand DECODER, SET Control Mode SAP Sendcommand DECODER, SET SAP IP Mode ALTSendcommand DECODER,SET Video MPEG2 Sendcommand DECODER, SET Sesson CursorSendcommand DECODER,SET URL UDP 224.0.0.1 SET Session CursorRS-232/422/485 SendCommands Port RS-232/422/485 SendCommandsCtspsh OFF ChardmCtspsh GET BaudSET Baud RxoffRxon Tset BaudTxclr RS232/422/485 Ports ChannelsRS232/422/485 Ports Channels XoffRS-232/422/485 SendString Escape Sequences Port RS-232/422/485 SendString Escape SequencesIR / Serial Ports Channels IR/Serial Port Port 3 CommandsIR/Serial SendCommands IR / Serial Ports ChannelsCton GET ModeCtof POF IroffPOD PONSET IO Link PtofPton Sendcommand IR1, SP,25 SET ModeSendcommand IR1,SET Mode IR Short cable length 10 feetSendcommand IR1,XCH Sendcommand DEV,XCHM extended channel modeSendcommand IR1,XCHM XchmIR RX Port Channels Port Port Commands PortSend Commands GET InputBACKLIGHT-0 LCD Commands PortBacklight BACKLIGHT-50Page Programming MAX-CSE/MAX-CSD10 Operation/Reference Guide 103 It’s Your World Take Control
Related manuals
Manual 2 pages 62.62 Kb Manual 116 pages 15.94 Kb

MAX-CSD 10, MAX-CSE specifications

The AMX MAX-CSE and MAX-CSD 10 are advanced multimedia presentation systems designed to enhance communication and collaboration in various professional environments. These devices are tailored for modern conference rooms, educational institutions, and corporate settings, providing seamless integration of audio-visual technology to facilitate effective presentations and meetings.

One of the standout features of the MAX-CSE and MAX-CSD 10 is their sophisticated audio and video processing capabilities. The MAX-CSE serves as a central management hub, supporting high-definition video outputs and multiple input sources, including HDMI, VGA, and wireless connectivity options. This versatility ensures that users can connect a wide array of devices—laptops, tablets, and smartphones—without hassle and quickly switch between them during presentations.

The MAX-CSD 10 complements the MAX-CSE as a dedicated audio unit equipped with powerful amplification and precise tuning. It delivers clear and balanced sound, even in larger rooms, ensuring that every participant can engage fully, regardless of their location in the space. With features like echo cancellation and noise reduction technology, the MAX-CSD 10 enhances voice clarity, making it ideal for video conferencing and webinars.

An important characteristic of the AMX MAX series is their user-friendly interface. The systems are designed for intuitive operation, enabling users to control various settings with ease, whether they are tech-savvy or not. The touch panel interface can be customized to meet specific needs, allowing quick access to essential functions such as lighting, video routing, and audio control.

In terms of connectivity, both systems are equipped with robust network capability, allowing integration with existing IT infrastructure. This feature ensures that users can manage and control the systems remotely through a web interface or compatible applications, enhancing productivity and easing the overall user experience.

Robust security measures are also a significant aspect of the AMX MAX-CSE and MAX-CSD 10 systems. They are designed with advanced encryption and user authentication protocols, ensuring that sensitive data remains protected during presentations and meetings.

In conclusion, the AMX MAX-CSE and MAX-CSD 10 multimedia presentation systems stand out in the market due to their superior audio and video quality, user-friendly features, and extensive connectivity options. They are ideal solutions for professionals seeking to leverage technology for more productive and engaging communication.