AMX MAX-CSD 10 Sendcommand DECODER, SET Control Mode SAP, Sendcommand DECODER,SET Format PAL

Page 93

 

NetLinx Programming

 

MAX-CSD Streaming Send_Commands (Cont.)

 

 

Command

Description

 

 

SET CONTROL MODE

'MANUAL' mode lets the user to specify all parameters such as video decoder,

Set the control mode of the

audio decoder, transport type, and video and audio ports.

 

stream.

'SAP' mode allows the user to select a stream based on a SAP list. Streaming

 

will begin when the user chooses the stream from the SAP list and then send

 

the PLAY command

 

'RTSP' mode allows the user to specify the URL to a RTSP server. Streaming

 

will begin when the user enters the URL and then sends the PLAY command.

 

Syntax:

 

SEND_COMMAND <DEV>,'SET CONTROL MODE <Mode>'

 

Variable:

 

Mode = MANUAL or SAP or RTSP

 

Example:

 

SEND_COMMAND DECODER, 'SET CONTROL MODE SAP'

 

 

SET FORMAT

Syntax:

Set the video format of the

SEND_COMMAND <DEV>,'SET FORMAT <Format>'

incoming video stream.

Variable:

 

 

Format = NTSC or PAL

 

Example:

 

SEND_COMMAND DECODER,'SET FORMAT PAL'

 

Tells the decoder to expect PAL video format.

 

 

SET RTSP SERVER

The list is limited to a total of 10 entries.

Sets an RTSP Server entry

Syntax:

into a list.

SEND_COMMAND <DEV>, 'SET RTSP SERVER <num> <url> <ipaddr>

 

 

<port>'

 

Variables:

 

num = 1 to 10 entries that the user may use

 

url = universal resource locator specifying the RTSP Server

 

ipaddr = ip address of RTSP Server. This value will be used if DNS is not

 

available. Otherwise DNS will be used with www.foo.com as the example

 

specifies.

 

port = ip port of the RTSP server. Set to 0 to contact RTSP server with the

 

'default' port (RTSP default port is 554).

 

Example:

 

SEND_COMMAND DECODER, 'SET RTSP SERVER 1 rtsp://

 

www.foo.com/myvideo.sdp 10.0.0.101 0'

 

 

SET SAP IP MODE

'DEFAULT' mode tells SAP Listener to use the well known multicast

Sets the SAP Listener ip

address:port of 224.2.127.254:9875

 

address mode.

'ALT' modes tells the SAP Listener to use the alternative multicast

 

address:port. The alternative multicast address:port is configured via another

 

NetLinx command (see SET SAP IP ALT below).

 

Syntax:

 

SEND_COMMAND <DEV>, 'SET SAP IP MODE <Mode>'

 

Variable:

 

Mode=DEFAULT or ALT

 

Example:

 

SEND_COMMAND DECODER, 'SET SAP IP MODE ALT'

 

 

MAX-CSE/MAX-CSD10 Operation/Reference Guide

87

 

 

Image 93
Contents MAX-CSE/MAX-CSD10 AMX Limited Warranty and Disclaimer Table of Contents MAX-CSD10 Web Interface Configuration and Firmware Update Page MAX-CSE Video Encoder MAX Encoder FeaturesOverview MAX-CSE FG2178-70 ComponentsMAX-CSE Specifications MAX-CSE Product SpecificationsWhile in IR mode Sensing for IR ports MAX Decoder Features MAX-CSD10 Product SpecificationsMAX-CSD10 Video Decoder MAX-CSD10 FG2178-72 ComponentsAAC MAX-CSD10 FG2178-72 SpecificationsMAX-CSD10 Specifications Page MAX-CSE and MAX-CSD10 Connections and Wiring MAX-CSE and MAX-CSD10 InstallationWiring Guidelines Direct Power Port Assignments and FunctionalityPreparing captive wires Wiring length guidelinesWiring a power connection Wiring Guidelines Indirect Power via PoECSE MAX-CSE PoE Special wiring instructionsVDC power Supply Wiring the MAX-CSE connectors and cablesEthernet RJ-45 Pinouts and Signals Ethernet/RJ-45 Port Connections and WiringSignals Connection Pairing Color MICPower over Ethernet PoE wiring DB9 Device Port Connections and WiringEthernet LEDs IR/Serial Port Connections and Wiring Input/Output I/O Port Connections and WiringRS-232/422/485 Device Port Wiring Specifications Wiring the MAX-CSD10 connectors and cables Port Wiring SpecificationsPin Signal Function Installing Into an Equipment Rack Page MAX-CSE Web Interface Default Security ConfigurationSecurity Terms Security TermsDefault Security Configuration case-sensitive Administrator accountCommunicating with the unit via the browser-based UI User Interface Features MAX-CSE User Interface Overview and FeaturesFeature Description Navigation Bar Browser-based UI Application OverviewAdministration Page Features Feature DescriptionStream Status Administration AdministrationFeature Description Resources Example Computer CourseChanging the Program Description ModeUpload Firmware Upgrading New Firmware Click Upload a File Click Reboot done. Upload a FileStream Profiles Stream ProfilesStream Profiles Page Features Feature Description Encoder ProfileVideo Audio ResolutionStream SVCD, MP3Obtaining the IP information for a target Modero SAP SettingsChanging the Encoder Profile Encoder Profiles and ParametersVCR Set up Set up Page FeaturesFeature Description Video Changing Video and Audio Settings NetLinx SettingsFeature Description NetLinx Master NetLinx Settings Page FeaturesChanging the NetLinx Master Connection IP SettingsIP Settings Page Features Changing the IP SettingsFeature Description IP Address DNS AddressUser Page Features Feature Description UserUser Changing User Settings Feature Description Browser Address field MAX-CSD10 User Interface Overview and FeaturesMAX-CSD10 Web Interface Navigation frameFeature Description Stream Status frame LogoffActive Page frame Updating Firmware Communicating With The Unit Via the Browser-based UIStream Selector Stream Selector Page FeaturesStream Set-up Stream Set-up Page FeaturesChanging the stream configuration Setting up an SAP stream configurationSetting up an Rtsp stream configuration Stream Configuration Page Manual Mode Setting up a Manual stream configurationNetLinx Page Features Audio/Video Page FeaturesAudio/Video NetLinxTo make changes to the IP Settings User Page Details To change the User Login SettingsReading the Front Panel LCD Configuring CommunicationObtaining the unit’s initial Dhcp Address Configuring the MAX Communication ParametersSave login profile selection box Communicating with the Target Master via an IP Assigning Master Communication Settings and TCP/IP Settings Associating a MAX-CSE to a Target Master Associating the MAX unit to a Target MasterStudio Online Tree tab showing the communicating MAX unit Associating a MAX-CSD10 Unit to a Target Master Changing the MAX’s Device NumberChanging the MAX-CSE device number via the UI Changing the MAX-CSE device number via StudioRecommended NetLinx Device numbers Using the ID button to change the MAX-CSE’s Device ValueChanging the MAX-CSD10 device number via the UI Before You Begin Configuration and Firmware UpdateMAX vs. NetLinx Master Functional Overlap Verifying the MAX’s current version of Firmware via the UIUpgrading MAX Firmware Verifying the MAX’s current version of Firmware via StudioUpgrading MAX-CSE Firmware via the UI Upgrading the MAX’s Firmware via NetLinx Studio Upgrading MAX-CSD10 Firmware via the UIClick Close once the download process is complete Requirements for Receiving Streamed Content Displaying Stream ContentObtaining the IP Address of the target panel Setting up a Modero Panel to Receive and Display a StreamSystem Settings Configuring the MAX-CSE for communicationStream Profiles V Setup Configuring the MAX-CSE audio/video inputsSetting up a streaming page within TPDesign4 Rtpmpeg#//IP Address of MAX-CSETarget Video Port Establishing the final connection between the two units Video Adjustment page showing default valuesSetting up a Computer to Receive and Display a Stream Configure the MAX-CSE for communication to a computerObtaining the IP Address of the target computer Displaying Stream Content RTP Video Stream Component RTP Audio Stream Component Page DevicePortSystem DPS NetLinx ProgrammingPort Assignments Port/DescriptionMAX-CSE Streaming SendCommands MAX-CSE Streaming Commands PortCommand Description GET AsourceGET Format GET SAP IP ModeGET Gain GET SAPGET Session Info GET Session ListGET Stream Status GET URL GET VideoGET Video Port Status Play GET VsourceSET Asource SET AudioSET Format SET SAP IP ModeSET Gain SET SAPSendcommand ENCODER,SET Video MPEG2 D1 6000 CBR SET URLSET Video MAX-CSD Streaming SendCommands MAX-CSD Streaming Commands PortSET Vsource StopGET Control Mode GET Rtsp ServerGET Session Cursor Sendcommand DECODER, GET Session Info 2 Title Sendcommand DECODER, GET Session Info 1 TitleSendcommand DECODER, GET Session Info 2 MEDIA1 Sendcommand DECODER, GET Session Info 2 MEDIA2Sendcommand DECODER,GET Video Sendcommand DECODER,GET URLSendcommand DECODER, Play Sendcommand DECODER,SET Audio MP3Sendcommand DECODER, SET Control Mode SAP SET Control ModeSendcommand DECODER,SET Format PAL Sendcommand DECODER, SET SAP IP Mode ALTSendcommand DECODER,SET URL UDP 224.0.0.1 Sendcommand DECODER, SET Sesson CursorSendcommand DECODER,SET Video MPEG2 SET Session CursorRS-232/422/485 SendCommands RS-232/422/485 SendCommands PortCtspsh ChardmCtspsh OFF GET BaudRxon RxoffSET Baud Tset BaudRS232/422/485 Ports Channels RS232/422/485 Ports ChannelsTxclr XoffRS-232/422/485 SendString Escape Sequences RS-232/422/485 SendString Escape Sequences PortIR/Serial SendCommands IR/Serial Port Port 3 CommandsIR / Serial Ports Channels IR / Serial Ports ChannelsGET Mode CtofCton POD IroffPOF PONPtof PtonSET IO Link Sendcommand IR1,SET Mode IR SET ModeSendcommand IR1, SP,25 Short cable length 10 feetSendcommand IR1,XCHM Sendcommand DEV,XCHM extended channel modeSendcommand IR1,XCH XchmSend Commands Port Commands PortIR RX Port Channels Port GET InputBacklight LCD Commands PortBACKLIGHT-0 BACKLIGHT-50Page Programming MAX-CSE/MAX-CSD10 Operation/Reference Guide 103 It’s Your World Take Control
Related manuals
Manual 2 pages 62.62 Kb Manual 116 pages 15.94 Kb

MAX-CSD 10, MAX-CSE specifications

The AMX MAX-CSE and MAX-CSD 10 are advanced multimedia presentation systems designed to enhance communication and collaboration in various professional environments. These devices are tailored for modern conference rooms, educational institutions, and corporate settings, providing seamless integration of audio-visual technology to facilitate effective presentations and meetings.

One of the standout features of the MAX-CSE and MAX-CSD 10 is their sophisticated audio and video processing capabilities. The MAX-CSE serves as a central management hub, supporting high-definition video outputs and multiple input sources, including HDMI, VGA, and wireless connectivity options. This versatility ensures that users can connect a wide array of devices—laptops, tablets, and smartphones—without hassle and quickly switch between them during presentations.

The MAX-CSD 10 complements the MAX-CSE as a dedicated audio unit equipped with powerful amplification and precise tuning. It delivers clear and balanced sound, even in larger rooms, ensuring that every participant can engage fully, regardless of their location in the space. With features like echo cancellation and noise reduction technology, the MAX-CSD 10 enhances voice clarity, making it ideal for video conferencing and webinars.

An important characteristic of the AMX MAX series is their user-friendly interface. The systems are designed for intuitive operation, enabling users to control various settings with ease, whether they are tech-savvy or not. The touch panel interface can be customized to meet specific needs, allowing quick access to essential functions such as lighting, video routing, and audio control.

In terms of connectivity, both systems are equipped with robust network capability, allowing integration with existing IT infrastructure. This feature ensures that users can manage and control the systems remotely through a web interface or compatible applications, enhancing productivity and easing the overall user experience.

Robust security measures are also a significant aspect of the AMX MAX-CSE and MAX-CSD 10 systems. They are designed with advanced encryption and user authentication protocols, ensuring that sensitive data remains protected during presentations and meetings.

In conclusion, the AMX MAX-CSE and MAX-CSD 10 multimedia presentation systems stand out in the market due to their superior audio and video quality, user-friendly features, and extensive connectivity options. They are ideal solutions for professionals seeking to leverage technology for more productive and engaging communication.