AMX MAX-CSD 10, MAX-CSE manual RS-232/422/485 SendCommands Port

Page 95

 

NetLinx Programming

 

MAX-CSD Streaming Send_Commands (Cont.)

 

 

Command

Description

 

 

START RTSP SERVER

If the RTSP SERVER started properly the 'GET SESSION LIST' table will

Attempts to START the RTSP

return with a 1. Otherwise it will return 0. This command is not accessible if

SERVER and will retrieve

system mode is not set to RTSP

Syntax:

and update the session list

info.

SEND_COMMAND <DEV>, 'START RTSP SERVER <num>'

 

 

Variables:

 

num = 1 to 10: One of the ten RTSP SERVER Entries.

 

Example:

 

SEND_COMMAND <DEV>, 'START RTSP SERVER 2'

 

 

STOP

Stops reception of audio and video.

Stops transmission of audio

Syntax:

and video.

SEND_COMMAND <DEV>,'STOP'

 

 

Example:

 

SEND_COMMAND DECODER, 'STOP'

 

 

RS-232/422/485 Send_Commands (Port 2)

The serial port is located at Port 2 in NetLinx D:P:S nomenclature. The serial port supports the following commands and escape sequences. In these examples: <DEV> = device.

RS-232/422/485 Send_Commands

Command

Description

 

 

B9MOFF

Disables 9-bit in 232/422/455 mode. By default, this returns the communication

Set the port's communication

settings on the serial/data port to the last programmed parameters. This

parameters for stop and data

command works in conjunction with the 'B9MON' command.

Syntax:

bits according to the software

settings on the RS-232 port

SEND_COMMAND <DEV>,"'B9MOFF'"

(default).

Example:

 

 

SEND_COMMAND RS232_1,"'B9MOFF'"

 

Sets the RS-232 port settings to match the port's configuration settings.

 

 

B9MON

Enables 9-bit in 232/422/455 mode. This command works in conjunction with

Override and set the current

the 'B9MOFF' command.

Syntax:

communication settings and

parameters on the RS-232

SEND_COMMAND <DEV>,"'B9MON'"

port to 9 data bits with one

Example:

stop bit.

 

 

SEND_COMMAND RS232_1,"'B9MON'"

 

Resets the RS-232 port's communication parameters to nine data bits, one

 

stop bit, and locks-in the baud rate.

 

 

CHARD

Syntax:

Set the delay time between

SEND_COMMAND <DEV>,"'CHARD-<time>'"

all transmitted characters to

Variable:

the value specified (in 100

time = 0 - 255. Measured in 100 microsecond increments.

Microsecond increments).

Example:

 

 

SEND_COMMAND RS232_1,"'CHARD-10'"

 

Sets a 1-millisecond delay between all transmitted characters.

 

 

MAX-CSE/MAX-CSD10 Operation/Reference Guide

89

 

 

Image 95
Contents MAX-CSE/MAX-CSD10 AMX Limited Warranty and Disclaimer Table of Contents MAX-CSD10 Web Interface Configuration and Firmware Update Page MAX-CSE FG2178-70 Components MAX Encoder FeaturesMAX-CSE Video Encoder OverviewMAX-CSE Specifications MAX-CSE Product SpecificationsWhile in IR mode Sensing for IR ports MAX-CSD10 FG2178-72 Components MAX-CSD10 Product SpecificationsMAX Decoder Features MAX-CSD10 Video DecoderAAC MAX-CSD10 FG2178-72 SpecificationsMAX-CSD10 Specifications Page Port Assignments and Functionality MAX-CSE and MAX-CSD10 InstallationMAX-CSE and MAX-CSD10 Connections and Wiring Wiring Guidelines Direct PowerWiring Guidelines Indirect Power via PoE Wiring length guidelinesPreparing captive wires Wiring a power connectionCSE MAX-CSE PoE Special wiring instructionsVDC power Supply Wiring the MAX-CSE connectors and cablesMIC Ethernet/RJ-45 Port Connections and WiringEthernet RJ-45 Pinouts and Signals Signals Connection Pairing ColorEthernet LEDs Power over Ethernet PoE wiringDB9 Device Port Connections and Wiring RS-232/422/485 Device Port Wiring Specifications IR/Serial Port Connections and WiringInput/Output I/O Port Connections and Wiring Pin Signal Function Wiring the MAX-CSD10 connectors and cablesPort Wiring Specifications Installing Into an Equipment Rack Page Security Terms Default Security ConfigurationMAX-CSE Web Interface Security TermsCommunicating with the unit via the browser-based UI Default Security Configuration case-sensitiveAdministrator account Browser-based UI Application Overview MAX-CSE User Interface Overview and FeaturesUser Interface Features Feature Description Navigation BarStream Status Administration Page FeaturesFeature Description Example Computer Course AdministrationAdministration Feature Description ResourcesUpload Firmware Changing the Program DescriptionMode Upgrading New Firmware Click Upload a File Click Reboot done. Upload a FileStream Profiles Stream ProfilesVideo Stream Profiles Page FeaturesFeature Description Encoder Profile Audio ResolutionStream SVCD, MP3Obtaining the IP information for a target Modero SAP SettingsVCR Changing the Encoder ProfileEncoder Profiles and Parameters Feature Description Video Set upSet up Page Features Changing Video and Audio Settings NetLinx SettingsFeature Description NetLinx Master NetLinx Settings Page FeaturesChanging the NetLinx Master Connection IP SettingsDNS Address Changing the IP SettingsIP Settings Page Features Feature Description IP AddressUser User Page FeaturesFeature Description User Changing User Settings Navigation frame MAX-CSD10 User Interface Overview and FeaturesFeature Description Browser Address field MAX-CSD10 Web InterfaceActive Page frame Feature Description Stream Status frameLogoff Updating Firmware Communicating With The Unit Via the Browser-based UIStream Selector Stream Selector Page FeaturesStream Set-up Stream Set-up Page FeaturesSetting up an Rtsp stream configuration Changing the stream configurationSetting up an SAP stream configuration Stream Configuration Page Manual Mode Setting up a Manual stream configurationNetLinx Audio/Video Page FeaturesNetLinx Page Features Audio/VideoTo make changes to the IP Settings User Page Details To change the User Login SettingsReading the Front Panel LCD Configuring CommunicationObtaining the unit’s initial Dhcp Address Configuring the MAX Communication ParametersSave login profile selection box Communicating with the Target Master via an IP Assigning Master Communication Settings and TCP/IP Settings Associating a MAX-CSE to a Target Master Associating the MAX unit to a Target MasterStudio Online Tree tab showing the communicating MAX unit Changing the MAX-CSE device number via Studio Changing the MAX’s Device NumberAssociating a MAX-CSD10 Unit to a Target Master Changing the MAX-CSE device number via the UIRecommended NetLinx Device numbers Using the ID button to change the MAX-CSE’s Device ValueChanging the MAX-CSD10 device number via the UI Verifying the MAX’s current version of Firmware via the UI Configuration and Firmware UpdateBefore You Begin MAX vs. NetLinx Master Functional OverlapUpgrading MAX-CSE Firmware via the UI Upgrading MAX FirmwareVerifying the MAX’s current version of Firmware via Studio Upgrading the MAX’s Firmware via NetLinx Studio Upgrading MAX-CSD10 Firmware via the UIClick Close once the download process is complete Requirements for Receiving Streamed Content Displaying Stream ContentObtaining the IP Address of the target panel Setting up a Modero Panel to Receive and Display a StreamSystem Settings Configuring the MAX-CSE for communicationStream Profiles V Setup Configuring the MAX-CSE audio/video inputsSetting up a streaming page within TPDesign4 Rtpmpeg#//IP Address of MAX-CSETarget Video Port Establishing the final connection between the two units Video Adjustment page showing default valuesObtaining the IP Address of the target computer Setting up a Computer to Receive and Display a StreamConfigure the MAX-CSE for communication to a computer Displaying Stream Content RTP Video Stream Component RTP Audio Stream Component Page Port/Description NetLinx ProgrammingDevicePortSystem DPS Port AssignmentsGET Asource MAX-CSE Streaming Commands PortMAX-CSE Streaming SendCommands Command DescriptionGET SAP GET SAP IP ModeGET Format GET GainGET Stream Status GET Session InfoGET Session List GET Video Port Status GET URLGET Video SET Audio GET VsourcePlay SET AsourceSET SAP SET SAP IP ModeSET Format SET GainSET Video Sendcommand ENCODER,SET Video MPEG2 D1 6000 CBRSET URL Stop MAX-CSD Streaming Commands PortMAX-CSD Streaming SendCommands SET VsourceGET Session Cursor GET Control ModeGET Rtsp Server Sendcommand DECODER, GET Session Info 2 MEDIA2 Sendcommand DECODER, GET Session Info 1 TitleSendcommand DECODER, GET Session Info 2 Title Sendcommand DECODER, GET Session Info 2 MEDIA1Sendcommand DECODER,SET Audio MP3 Sendcommand DECODER,GET URLSendcommand DECODER,GET Video Sendcommand DECODER, PlaySendcommand DECODER, SET SAP IP Mode ALT SET Control ModeSendcommand DECODER, SET Control Mode SAP Sendcommand DECODER,SET Format PALSET Session Cursor Sendcommand DECODER, SET Sesson CursorSendcommand DECODER,SET URL UDP 224.0.0.1 Sendcommand DECODER,SET Video MPEG2RS-232/422/485 SendCommands RS-232/422/485 SendCommands PortGET Baud ChardmCtspsh Ctspsh OFFTset Baud RxoffRxon SET BaudXoff RS232/422/485 Ports ChannelsRS232/422/485 Ports Channels TxclrRS-232/422/485 SendString Escape Sequences RS-232/422/485 SendString Escape Sequences PortIR / Serial Ports Channels IR/Serial Port Port 3 CommandsIR/Serial SendCommands IR / Serial Ports ChannelsCton GET ModeCtof PON IroffPOD POFSET IO Link PtofPton Short cable length 10 feet SET ModeSendcommand IR1,SET Mode IR Sendcommand IR1, SP,25Xchm Sendcommand DEV,XCHM extended channel modeSendcommand IR1,XCHM Sendcommand IR1,XCHGET Input Port Commands PortSend Commands IR RX Port Channels PortBACKLIGHT-50 LCD Commands PortBacklight BACKLIGHT-0Page Programming MAX-CSE/MAX-CSD10 Operation/Reference Guide 103 It’s Your World Take Control
Related manuals
Manual 2 pages 62.62 Kb Manual 116 pages 15.94 Kb

MAX-CSD 10, MAX-CSE specifications

The AMX MAX-CSE and MAX-CSD 10 are advanced multimedia presentation systems designed to enhance communication and collaboration in various professional environments. These devices are tailored for modern conference rooms, educational institutions, and corporate settings, providing seamless integration of audio-visual technology to facilitate effective presentations and meetings.

One of the standout features of the MAX-CSE and MAX-CSD 10 is their sophisticated audio and video processing capabilities. The MAX-CSE serves as a central management hub, supporting high-definition video outputs and multiple input sources, including HDMI, VGA, and wireless connectivity options. This versatility ensures that users can connect a wide array of devices—laptops, tablets, and smartphones—without hassle and quickly switch between them during presentations.

The MAX-CSD 10 complements the MAX-CSE as a dedicated audio unit equipped with powerful amplification and precise tuning. It delivers clear and balanced sound, even in larger rooms, ensuring that every participant can engage fully, regardless of their location in the space. With features like echo cancellation and noise reduction technology, the MAX-CSD 10 enhances voice clarity, making it ideal for video conferencing and webinars.

An important characteristic of the AMX MAX series is their user-friendly interface. The systems are designed for intuitive operation, enabling users to control various settings with ease, whether they are tech-savvy or not. The touch panel interface can be customized to meet specific needs, allowing quick access to essential functions such as lighting, video routing, and audio control.

In terms of connectivity, both systems are equipped with robust network capability, allowing integration with existing IT infrastructure. This feature ensures that users can manage and control the systems remotely through a web interface or compatible applications, enhancing productivity and easing the overall user experience.

Robust security measures are also a significant aspect of the AMX MAX-CSE and MAX-CSD 10 systems. They are designed with advanced encryption and user authentication protocols, ensuring that sensitive data remains protected during presentations and meetings.

In conclusion, the AMX MAX-CSE and MAX-CSD 10 multimedia presentation systems stand out in the market due to their superior audio and video quality, user-friendly features, and extensive connectivity options. They are ideal solutions for professionals seeking to leverage technology for more productive and engaging communication.