•Interface Selection Switch SW2 for Port 1/2/3/4: ON * Set the port interface to
OFF Set the port interface to
•Data Mode Selection Switch SW1 for Port 1/2/3/4: (Valid if SW2 is ON) ON * Set the
•Termination Resistor Port 1/2/3/4 Jumper JP3/4/5/6: (Valid if SW2 is ON) Open * Not using Termination Resistor
Shor t Using Termination Resistor
In addition, it has the following default settings for I/O addresses and Interrupt number:
I/O address: | 0x180 (Port 1), 0x188 (Port 2), 0x190 (Port 3), 0x198 (Port 4) |
IRQ: | 10 |
INT Vector: | 0x1C0 |
Note ! If the default settings above ar e what you desir ed and good for the system without conflicts, you may simply install the boar d in the system and go dir ectly to the next chapter , “Softwar e Installation”. Other wise, follow the instr uctions below.
2.After you set all the jumpers and switches, you should do either the nor mal har dwar e installation (detailed in the later section, “Hardware Installation with
•Only one Industio
•Windows NT and 95/98 are the only operating systems supported.
•CAP J umper J P1 is shor t and I/O address 0xA700 must be free.
Quick Hardware Installation
To fully utilize the superior feature of flexible hardware configuration design of the Industio