Moxa Technologies RS-485, RS-422 user manual Nor mal Speed Spectr um High Speed Spectr um

Page 20

However, if the port is driven by NON Moxa-pr ovided dr iver , such as standar d ser ial dr iver , or Moxa drivers other than Windows NT and 95/98, such as DOS and Windows 3.x, the real working speed is equal to 8 times of the displayed speed. For example, a port, if set to Normal Speed Spectrum with 38.4 Kbps, will work at 38.4 Kbps for sure; while a port, if set to High Speed Spectrum with displayed speed 38.4 Kbps, will actually work at 307.2 Kbps (38.4 Kbps¡Ñ8).

The following is the 8 times speed mapping list for quick reference purpose, par ticular ly for DOS and Windows 3.x dr iver .

Nor mal Speed Spectr um

High Speed Spectr um

 

50 (bps)

400 (bps)

75

600

110

880

134.5

1076

150

1200

300

2400

600

4800

1200

9600

1800

14.4K

2400

19.2K

4800

38.4K

7200

57.6K

9600

76.8K

 

19.2K

153.6K

 

38.4K

307.2K

 

57.6K

460.8K

 

115.2K

921.6K

INT Vector Enter the interrupt vector I/O address for all ports. I/O address for interrupt vector is from 00000H to 0FFFFH. Interrupt vector is one byte of I/O address, in which each bit is used to indicate the occurrence of interrupt for corresponding port.

There are two modes for the Industio CI-134 Series driver. One is using interrupt vector, the other is not. To use interrupt vector, type in the hardware interrupt vector I/O address. If not using interrupt vector, type 0 or leave blank as the interrupt vector. Driver employing interrupt vector scheme is supposed to have better performance than employing polling scheme.

2-8Industio CI-134 Series User’s Manual

Image 20
Contents Industio CI-134 Series User’s Manual Mar 1st EditionIndustio CI-134 Series User’s Manual Copyright NoticeTrademarks DisclaimerMoxa Internet Services Hardware Installation Software InstallationConnection Cable and Cable Wiring TroubleshootingTable of Contents Technical Reference Connection Cable and Cable WiringTroubleshooting Overview Industio The Industrial Multiport Async SolutionIntroduction Automatic Data Direction Control for RS-485 Termination Resistors Ready for RS-422/RS-485Surge/Isolation Protection Asic Design, Compact SizeQuick Installation IntroductionOperating System Support Moxa Serial Comm ToolsFeatures Broad ApplicationsCheck List SCO Xenix QNXInstallation Guide Hardware Installation First Thing to Do Interface SettingsQuick Hardware Installation 0x1C0How to Do Quick Hardware Installation Hardware Installation with IO-IRQ Utility IO-IRQ Utility and Hardware Configuration 6Industio CI-134 Series User’s Manual Speed Port IndexAddress Nor mal Speed Spectr um High Speed Spectr um Press F10 to save the configuration and exit the utility 10Industio CI-134 Series User’s Manual Software Installation Windows NTInstalling Driver Software Installation 4Industio CI-134 Series User’s Manual Tx Fifo Size Port NumberRx Fifo Trigger 6Industio CI-134 Series User’s Manual Configuring Board and Port 8Industio CI-134 Series User’s Manual Updating Driver Removing DriverWindows 95/98 Software Installation 12Industio CI-134 Series User’s Manual Rx Fifo Trigger 14Industio CI-134 Series User’s Manual Updating Driver 16Industio CI-134 Series User’s Manual DOS Driver Setup Software Installation 20Industio CI-134 Series User’s Manual Por t number TxD buf size RxD buf size F5 Gr oup edit 22Industio CI-134 Series User’s Manual Loading Driver Unloading DriverWindows Software Installation Configuring Driver Baud Rate Settings 28Industio CI-134 Series User’s Manual Windows NT and Windows 95/98 PComm InstallationSerial Programming Tools Utilities Diagnostic for Moxa boards onlyPComm Programming Library Industio CI-134 Series User’s Manual Terminal Emulator Data Scope Installing API-232DOS API-232 Library 6Industio CI-134 Series User’s Manual Serial Programming Tools Diagnose Windows Comm API Library Win16 UtilityExisting Applications RS-485 Programming Automatic Data Direction Control Mode RecommendedBy RTS Mode For back-compatibility Solution 12Industio CI-134 Series User’s Manual CI-134 Connection Cable and Cable WiringRS-422 Cable Wiring RS-422 Point-to-point RS-422 Broadcasting RS-485 Cable Wiring Impedance Matching and Termination Resistors For RS-485 Mode DB-37 Connector Pin OutsFor RS-422 Mode 6Industio CI-134 Series User’s Manual Hardware causes and solutions TroubleshootingGeneral Troubleshooting Software Causes and Solutions Io-ir q Remove the jumper on position JP1 Windows NT system panic blue scr een DOS Specifications Technical ReferenceUart TI550C PC I/O Port Address Map IO/ Addr ess DeviceProblem Report Form Return Procedure