3.3 DIAGNOSTICS MODE
ADVANCE SETUP 1
> HOST SYSTEM 9750 |
| |||||||
COM 1 | 4800 |
| 8E | |||||
COM 2 | 4800 |
| 8E | |||||
COM 3 | 4800 |
| 8E | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Diagnostics mode is activated when DIP switch 1 is ON. To leave diagnostics mode,
select and return DIP switch 1 to the OFF position. Diagnostics mode allows you to test the:
1.LCD display
2.Keys
3.Serial ports (not available at this time)
4.DIP switches
3.3.1 Testing the Display
DIAGNOSTIC MODE V3.3 |
LCD TEST |
1.While in diagnostics mode, select .
2.Select to test Graphic Page 0.
3.Select to test Graphic Page 1.
4.Select to test Graphic Page 2.
5.Select to test the text page.
6.Select .
3.3.2 Testing the Keys
KEYBOARD TEST V3.3
PLEASE ENTER A KEY
JOYSTICK POSITION - (129,129)
NOTE: When testing the keyboard, pressing the user definable control keys causes their assigned functions to be displayed.
1. | While in diagnostics mode, select | . | |
2. | Press each key and check that the display indicates the correct key. | ||
3. | Select | . |
|
3.3.3 Testing the Serial Ports
(For factory use only)
3.3.4 Testing the DIP Switch
DIP SWITCH TEST V3.3
00000011
NOTE: When switched ON, func- tioning switches will change the cor- respondingly displayed ‘0’ to a ‘1’. For instance, when switch 2 is ON, the display should read: 00000011.
1.Select .
2.Beginning with switch 2, set each switch to ON while observing the display.
Pelco Manual C540M (6/98) | 17 |