Pelco C540M (6/98), CM9760-KBR General, Important Safeguards and Warnings, Certifications, Fcc

Page 5

1.0 GENERAL

1.1 IMPORTANT SAFEGUARDS AND WARNINGS

Prior to installation and use of this product, the following WARNINGS should be observed.

1.Installation and servicing should only be done by qualified service personnel and conform to all local codes.

2.Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6 or 6P enclosure, it is designed for Indoor use only and it must not be installed where exposed to rain and moisture.

3.Only use replacement parts recommended by Pelco.

4.After replacement/repair of this unit’s electrical components, conduct a resis- tance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.

Please thoroughly famil- iarize yourself with the information in this manual prior to installation and operation.

NOTE: This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commerical environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful inter- ference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own ex- pense.

The product and/or manual may bear the following marks:

This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.

This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.

CAUTION:

RISK OF

ELECTRIC SHOCK.

DO NOT OPEN.

CAUTION:

TO REDUCE THE RISK OF ELECTRICAL SHOCK,

DO NOT REMOVE COVER. NO USER-

SERVICEABLE PARTS INSIDE. REFER SERVICING

TO QUALIFIED SERVICE PERSONNEL.

1.2 CERTIFICATIONS

The products identified below have been tested and certified for agency compli- ance as noted.

 

Agency Compliance Certification

 

 

 

 

 

Model

CE

FCC

UL

CSA/cUL

CM9760-KBD-X

X

X

 

 

CM9760-KBD

 

X

 

 

Applicable CE, FCC, UL, and CSA/cUL directives/standards:

93/68/EEC–CE Mark Directive

89/336/EEC, 92/31/EEC–Electromagnetic Compatibility (EMC) Directives

FCC–47 CFR, Part 15, Subpart B, Class A

Pelco Manual C540M (6/98)

5

Image 5
Contents Esc Contents Advanced Operation Preset Camera Positions Manual # Date Comments List of IllustrationsRevision History General Important Safeguards and WarningsCertifications FCCDescription Main FeaturesModels CM9760-KBR-X Same as CM9760-KBR except 230 VAC, 50 HzLCD Display Physical LayoutMultipurpose Function Keys KeypadLens Control Function ControlSetup Installation and SetupTo Activate Setup Mode Assign functions to user-definable control keysCM9760-CC1 CM9760-KBD Basic Keyboard Setup Configuration and WiringCreating a Setup PIN To Leave Setup ModeAdjusting the Display Brightness Creating a Define PINCamera Direct Control Direct Camera Control/Serial Port SpeedsSerial Port Speeds Configuring the RelaysDownloading Keyboard Setups Setting Up a Receiver/DriverKeyboard Define Mode Setup information that can be downloaded/uploaded includesDownloading Keyboard to Keyboard Setups are downloaded keyboard to keyboard byAssigning Logical Camera Numbers Downloading Through the CM9760 System Adjusting the Time-out PeriodTesting the Display Diagnostics ModeTesting the Keys Testing the Serial PortsIntroduction OperationOverview Logging onLogging OFF Using the keypad, enter a monitor number, and then press orSelecting Monitors Selecting CamerasSelecting Group Cameras Locking Cameras or Input DevicesGroup Input Selection Overriding Camera Locks Operating PTZ CamerasOverriding Camera Control Recalling Presets Preset Camera PositionsCreating Presets Deleting PresetsVCR Control VCR Recording with the Pelco Alarm Interface Unit AIUVCR Control Via the Pelco IR Controller To control VCRs, see .3 GPI controlGPI Control Type the GPI number using the keypad and then pressSelecting GPIs MacrosFinding Macros Pausing MacrosRestarting Macros Creating Temporary Macros Deleting MacrosVideo Loss Camera is disabledCamera Sequences Setting the Time and DateArming Alarms AlarmsDisarming Alarms Or selectResetting Triggered Alarms Alarm StatusResetting Alarms Appendix B. Icon Legend AppendicesAppendix A. Keyboard LCD Default Menu and Tree List Appendix B. Icon Lagend RS-232 Serial Port Appendix C. Keyboard Connector Pin-OutsRS-422 Serial Port JP4 Pin Function I2C Bus PortRelay Port JP5 PinSame Direction Appendix D. Keyboard-to-Keyboard Cabling ConnectionsOpposite Tree DIP Switch 2 on Appendix E. Setup Mode MenuDiagnostic Mode LCD Test Keyboard Test Appendix F. Diagnostic Mode Menu Tree DIP Switch 1 onDiagnostic Mode Serial Port Test Diagnostic Mode DIP Switch TestElectrical Appendix G. CM9760-KBD SpecificationsOperational GeneralReturns Warranty and Return InformationWarranty

C540M (6/98), CM9760-KBR specifications

The Pelco CM9760-KBR and C540M (6/98) are part of Pelco’s renowned line of video management solutions, tailored for both security and surveillance operations. These devices embody the cutting-edge technology and features that Pelco is known for, providing flexibility, functionality, and seamless integration in diverse environments.

The Pelco CM9760-KBR is a sophisticated keyboard and control system designed to manage various cameras and monitor systems effectively. It is equipped with an intuitive interface that allows operators to control PTZ (pan-tilt-zoom) cameras, adjust settings, and navigate between multiple camera feeds effortlessly. The user-friendly design of the CM9760-KBR ensures that even operators with minimal training can efficiently manage surveillance tasks.

One of the standout features of the CM9760-KBR is its ability to interface with multiple Pelco systems, making it highly compatible and adaptable for various surveillance setups. The keyboard supports a wide range of configurations and can integrate with different Pelco video multiplexers and decoders, offering a comprehensive control mechanism for video feeds.

The C540M is a reliable monitor that complements the CM9760-KBR, ensuring that operators have a clear view of their surveillance areas. It provides high-resolution video output, enabling detailed observation and analysis, which is critical in security monitoring. The monitor's robust construction and quality display make it suitable for both indoor and outdoor environments, maintaining performance even under challenging conditions.

Both the CM9760-KBR and C540M are designed to prioritize security features. They incorporate advanced encryption technologies to protect data and ensure privacy, which is essential for compliance with various regulatory standards. Additionally, the devices support remote access capabilities, allowing security personnel to monitor and manage their systems from offsite locations, enhancing operational flexibility.

In terms of technology, Pelco’s commitment to innovation is evident in these products. They utilize state-of-the-art video processing technology to deliver high-quality images, even in low-light conditions. This ensures that surveillance is effective 24 hours a day, making it easier to track movement and identify potential security threats.

In summary, the Pelco CM9760-KBR and C540M (6/98) are integral components of modern surveillance systems. With their advanced features, robust design, and high compatibility, they provide security professionals with the tools they need to ensure comprehensive monitoring and protection across various applications. Pelco continues to set the standard in surveillance technology, making their products a preferred choice for security operations worldwide.