JAI TM/TMC-4200CL operation manual Graphical User Interface

Page 25

Page 15

Graphical User Interface

The Table drop down menu offers three options.

The Linear option gathers light in a proportional manner. In this particular selection the LUT is configured to speed the light gathering capability at the beginning of the exposure.

The Gamma.45 option is designed to cause the camera to gather light for a result very similar to what the human eye sees. The heavier curved blue line represents the Gamma.45 LUT adjustment.

FIGURE 27. Gamma.45 imitates human eye sensitivity when creating an image.

The knee setting allows two adjustments in the light gathering configuration of the LUT to permit the camera to correct images as they are captured. It is possible to set knees on any of the drop down settings by clicking on the existing curve and moving it to the desired configuration. If a drop-down menu setting is selected without adjusting the knees, the camera sets the default.

FIGURE 28. The knee setting activates when “Send Knees” is clicked.

Dual-Tap TM-4200CL AccuPiXEL Series Camera-Control Software

Image 25
Contents TM/TMC-4200CL Series Progressive Scan Cameras Page CE Compliance Iii NoticeJAI PULNiX, Inc TM-4200CL Series Progressive Scan CameraPage Table of Contents Serial Communication Kit List of Figures List of FiguresList of Figures List of Tables List of TablesList of Tables Software Installation Software Use and Installation IntroductionDual-Tap TM-4200CL AccuPiXEL Series Camera-Control Software Setup installs Dual Tap AccuPIXel v Installing the Camera Link API DLL clserXXX.dll Software Use and Installation IntroductionRunning Dual Tap AccuPiXEL Screen grabber has an essential .dll file Uninstalling the SoftwareSoftware Use and Installation Introduction TM/TMC-4200CL Camera TM/TMC-4200CL CameraGraphical User Interface GUI FeaturesGraphical User Interface GigE Mode Using the CamLink ModeOperating The Control Software Check Current Camera SettingExposure Control Shutter SpeedScan Area Scan Area drop down box Offset Voltage Graphical User Interface Gain Control Gain Video Depth Ctrl SignalsImage Pre-Processing LUT Look-Up Table Graphical User Interface TriggerPositive or Negative LUT Selection Graphical User Interface Report Section PasswordMain Menu Option Knee ControlTest Pattern EepromLoad SaveMain Menu About Main Menu ConnectivityExit Product Description Hardware IntroductionTM/TMC-4200CL Series Progressive Scan Cameras Hardware Introduction FeaturesWarranty System ConfigurationOutput Dual-Channel Auto Black Level Balancing and Gain BalancingCamera Setup InstallationGetting Started 2 a 12-Pin Connector Connector Pin ConfigurationsPin Connector Pin DescriptionCamera Link Connector Pin # Description Digital I/O ConnectorAnalog Output Connector Power Supplies and Power Cable Setup Installation Camera Link CablePower Supplies Building Your Own Power Cable JAI Power CablesAttaching the Power Cable to the Connector 12P-02S Interface Cable Pin# Lead Color FunctionAttaching the Camera Lens Installation Attaching the Analog Video OutputCamera Rear Pane Functions and OperationsDigital Video Output Sensor Layer and TimingCamera Timing Chart Scan Area Preset Scan AreaFunctions and Operations Programmable Scan Area Bayer Full Scan Area 2x2 BinningX2 Binning Sub-sampling Digital ZoomSub-sampling Digital Zoom Functions and Operations Sub-sampling Digital Zoom Scan Area Start Points Programmable Exposure-Continuous Mode Preset ShutterAsynchronous No Shutter Mode Electronic Preset ShutterExternal Trigger Timing Asynchronous Programmable Exposure ModeAsynchronous Programmable External Trigger Pulse Width Control ModePulse Width Control Trigger Particle Imaging Velocimetry Fixed Exposure ModeTiming Scan Mode Unit Functions and Operations PWC PIV ModeFunctions and Operations Async no Shutter Async Preset and Prog. Shutter Asynchronous Mode ChartDynamic Range Control PIV Fixed ExpoProgrammable Look-Up Table LUT and Knee Control External Sync and Pixel Locking Serial Communication Kit Serial Communication KitSerial Communication Kit TM-4200CL Command List TM-4200CL Command ListScan Mode Channel Balance Lookup TableVsub Image Pre-processing Dual Tap Digital Video Output OrderMiscellaneous Command Parameter End of Cmd Description TM-4200CL Command Response TableSerial Communication Kit Serial Communication Kit Problems and Solutions Problems and SolutionsSymptom No Video Symptom Dark VideoInformation and Support Resources TM-4200CL Camera Specifications Table SpecificationsAppendix AppendixSpectral Response Appendix 1 TM-4200CL Physical DimensionsAppendix W . j a i p u l n i x . c o m