CV-M77
7 Configuring the camera using the serial interface.
7.1Mode Setting using ASCII commands via the RS-232C port.
The configuration of the
Below is the description of the ASCII based short command protocol.
The
7.2 | Communication setting |
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
| Baud Rate |
| 9600bps |
|
|
| |||
|
|
| Data Length |
| 8bit |
|
|
|
| ||
|
|
| Stop Bit |
|
| 1bit |
|
|
|
| |
|
|
| Parity |
|
| Non |
|
|
|
| |
|
|
| Xon/Xoff Control |
| Non |
|
|
|
| ||
7.3 | Command Protocol |
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| ||
|
| Command Name |
| Format |
|
|
| Parameter | Remarks | ||
A - | General settings and | useful commands. |
|
|
|
|
| ||||
|
|
|
|
|
|
| 0=Echo off |
| |||
1 | Echo back | EB=[Param.]<CR><LF> | 1=Echo on |
| |||||||
|
|
|
|
|
|
| Set to 'off' when power is on. |
| |||
2 | Firmware program | VN?<CR><LF> |
|
|
|
| Response is 3 letter | ||||
| version request |
|
|
|
|
|
| (ex) 100 | |||
B - | Timing and shutter related commands. |
|
|
|
|
| |||||
1 | Shutter mode | SM=[Param.]<CR><LF> | 0=Normal |
| |||||||
SM?<CR><LF> |
| 1=Programmable exposure |
| ||||||||
|
|
|
|
|
| ||||||
|
|
|
| SH=[Param.]<CR><LF> | 0=OFF(1/25), 1=1/50, 2=1/125, | Available when SM=0 and | |||||
2 | Shutter speed | 3=1/250, 4=1/500, 5=1/750, | |||||||||
SH?<CR><LF> |
| 6=1/1000, 7=1/1500, 8=1/2000, | TR=0 or 1or 3. | ||||||||
|
|
|
|
| |||||||
|
|
|
|
|
|
| 9=1/3000, 10=1/4000, 11=1/10000 |
| |||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| (1/10000s - 1/25s in 1HD |
| |||
| Programmable | PE=[Param.]<CR><LF> | increments) | Available when SM=1 and | |||||||
3 | 3= 1.5H(0.076ms) | ||||||||||
| exposure | PE?<CR><LF> |
| TR=0 or 1 or 3. | |||||||
|
|
|
|
|
|
| 4= | 2.5H(0.127ms) |
| ||
|
|
|
|
|
|
| : |
|
|
| |
|
|
|
|
|
|
| 791=789.5H(40.107ms) |
| |||
|
|
|
|
|
|
| 0=Normal |
| |||
|
|
|
| TR=[Param.]<CR><LF> | 1=Edge |
| |||||
4 | Trigger mode | 2=Pulse width control |
| ||||||||
TR?<CR><LF> |
| 3=Frame delay readout |
| ||||||||
|
|
|
|
|
| ||||||
|
|
|
|
|
|
| 4=Long time shutter |
| |||
|
|
|
|
|
|
| 5=PWC delay readout |
| |||
5 | Wen polarity | WP=[Param.]<CR><LF> | 0=Active_L, 1=Active_H |
| |||||||
WP?<CR><LF> |
|
| |||||||||
|
|
|
|
|
|
|
|
| |||
6 | G on SYNC | SY=[Param.]<CR><LF> | 0=OFF, 1=ON |
| |||||||
SY?<CR><LF> |
|
| |||||||||
|
|
|
|
|
|
|
|
| |||
7 | EEN polarity | EP=[Param.]<CR><LF> | 0=Active_L, 1=Active_H |
| |||||||
EP?<CR><LF> |
|
| |||||||||
|
|
|
|
|
|
|
|
| |||
8 | WEN/Sync switch | WS=[Param.]<CR><LF> | 0=WEN, 1=Sync |
| |||||||
WS?<CR><LF> |
|
| |||||||||
|
|
|
|
|
|
|
|
|
- 16 -