JAI CV-M77 operation manual 1023, Receiving Data Camera-PC

Page 17

 

 

 

 

CV-M77

 

 

 

 

 

 

 

 

 

C - Gain and analogue signals settings.

 

 

 

 

1

AGC switch

AS=[Param.]<CR><LF>

 

0=OFF (Manual), 1=ON (Auto)

 

 

AS?<CR><LF>

 

 

 

 

 

 

 

 

 

 

2

Master gain level

GA=[Param.]<CR><LF>

 

0-700

Available when AS=0.

 

GA?<CR><LF>

 

 

 

 

 

 

 

 

 

3

Red gain level

RG=[Param.]<CR><LF>

 

0-255

Available when WB=0.

 

RG?<CR><LF>

 

 

 

 

 

 

 

 

 

4

Blue gain level

BG=[Param.]<CR><LF>

 

0-255

Available when WB=0.

 

BG?<CR><LF>

 

 

 

 

 

 

 

 

 

5

AGC level

AG=[Param.]<CR><LF>

 

0-255

Available when AS=1.

 

AG?<CR><LF>

 

 

 

 

 

 

 

 

 

 

 

 

WB=[Param.]<CR><LF>

 

0=Manual (Variable)

Sets manual gain values

 

 

 

 

 

1=Auto (Variable)

 

6

White balance

 

(RG, BG) when changed

 

WB?<CR><LF>

 

2=4600K (Fixed)

 

 

 

 

 

to 0 from other selections.

 

 

 

 

 

 

3=5600K (Fixed)

 

 

 

 

 

 

 

 

7

Auto white balance

AW=[Param.]<CR><LF>

 

0=One push auto white balance

Available when WB=1.

 

 

 

 

 

 

 

 

 

8

Master setup level

SU=[Param.]<CR><LF>

 

33-223

 

 

SU?<CR><LF>

 

(default = 128)

 

 

 

 

 

 

 

 

9

Red setup level

RS=[Param.]<CR><LF>

 

96-160

 

 

RS?<CR><LF>

 

(default = 128)

 

 

 

 

 

 

 

 

10

Blue setup level

BS=[Param.]<CR><LF>

 

96-160

 

 

BS?<CR><LF>

 

(default = 128)

 

 

 

 

 

 

 

 

11

White clip level

WC=[Param.]<CR><LF>

 

0-1023

 

 

WC?<CR><LF>

 

 

 

12

Gamma select

GS=[Param.]<CR><LF>

 

0=1, 1=0.45, 2=0.6

 

 

GS?<CR><LF>

 

 

 

 

 

 

 

 

 

 

D -

saving and loading data in EEPROM

 

 

 

 

 

 

Load settings

 

 

0=FACTORY DATA AREA

 

 

1

(from camera

LD=[Param.]<CR><LF>

 

Latest used DATA AREA

 

 

1=USER DATA AREA

 

 

 

EEPROM)

 

 

becomes default at next

 

 

 

 

 

 

 

2

Save settings

SA=[Param.]<CR><LF>

 

1=USER DATA AREA

power up.

 

(to camera EEPROM)

 

 

 

3

Save settings into

SA00=[Param.]<CR><LF>

 

0=FACTORY DATA AREA

Not disclosed for user.

 

Factory Area.

 

 

 

 

 

 

 

4

EEPROM Current

EA?<CR><LF>

 

0=FACTORY DATA AREA

 

 

 

 

Area No. Request

 

 

1=USER DATA AREA

 

 

7.3.1Receiving Data (Camera->PC)

If the function succeeds, the return value is a handle to the newly allocated memory object. If the setting succeeds, returned is the below word from the camera.

COMPLETE<CR><LF>

Error Messages:

Command Error:

01Unknown Command!!<CR><LF>

Parameter Error:

02Bad Parameters!!<CR><LF>

Response to Request Command

Example:

 

Request Command (PC→Camera)

Receiving Data(Camera→PC)

Remarks

 

 

Command Name

Format

 

 

 

 

 

 

Trigger Mode

TR?<CR><LF>

TR=[Param.]<CR><LF>

"Param." is same as

 

 

setting command.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 17 -

 

 

Image 17
Contents CV-M77 CV-M77 Switch Settings Configuring the camera using the serial interfaceJumper settings CV-M77 Camera Control Tool SpecificationsPatterned Noise 12.3 General Standard Composition Main FeaturesCamera Housing and Dimensions 6-pin Multi-connector RS 232C/TRIGGER 12-pin Multi-connector DC-IN/SYNCPin No 1.1 Signal Remarks Pin No Signal Remarks9-pin DSUB-connector RGB/SYNC HD and VD input Input and Output CircuitsVideo input External Trigger Mode Input/Output of HD/VD SignalFunctions and Operation Continuous operationExtvd Exthd Pulse Width Control Trigger ModeLong Time Exposure Mode Frame-delay Readout ModeCV-M77 Timing diagram for Frame-delay Readout mode Timing diagram for Edge Pre-select mode Timing diagram for Pulse Width Control mode EEN WEN Timing diagram for Long Time Exposure modeMode Setting using Ascii commands via the RS-232C port Configuring the camera using the serial interfaceCommunication setting Command ProtocolReceiving Data Camera-PC 1023RS232C Cable Connections Response to firmware version request command ExampleMode Settings by Switch Switch SettingsSignals by Switch Settings 1 SW301 switch S3013 SW303 switch S303 2 SW302 switch S302S302-1 S302-2 Color temperature Jumper locations Jumper settingsPin Jumper tableCV-M77 Camera Control Tool Fig. Windows from the Camera Control Tools software Specifications Spectral sensitivity Typical CCD Characteristics PrecautionsAppendix ReferencesUsers Record Users Mode Settings Users ModificationsIndex Camera type CV-M77 Revision Revision a Serial No ……………