CV-M77
5.4Input and Output Circuits
In the following schematic diagrams the input and output circuits for video and timing signals are shown. For alternative connections refer to “Internal Switch and Jumper Settings”. Jumper settings are shown as for factory default.
5.4.1Video input
The video output signal is a 75Ω RGB video signal. The signal level is 0.7Vpp. Composite sync. is selectable on the green video signal via software or the internal switch
+5V
33KB
5.4.2 Trigger input
The trigger input is AC coupled with a
The trigger input impedance is 1.2 kΩ or 75Ω selectable via the internal switch
Trigger input
33KB
SC104V
1K8B
SC102V
100KB
75C
SC102V
GND
5.4.3HD and VD input
The HD and VD input circuit can be 75Ω terminated via the internal switch
The input signal level is 4V ± 2V.
+5V
33KB
HD, VD | SC104V |
1K8B | |
input | SC102V |
5.4.4HD, VD, PCLK, WEN and EEN output The output circuits for these signals are 75Ω complementary emitter followers. The single circuit delivers a TTL signal. The output level ≥ 4 V from 75Ω (no termination).
TTL
75C
+5V
10KB
220B
120C
150C
GND
Int VD Int HD PCKL WEN EEN
10KB
- 9 -