JAI CV-M538, CV-M536, CV-M539 operation manual Pulse width control mode for non-interlace only

Page 11

CV-M536/538/539

Cautions in the Pulse Width Control Mode.

1.Pulse width control mode is effective only in non-interlaced field accumulation mode.

2.The exposure start may be delayed up to 1H max., when the falling edge of ext. trigger pulse is not synchronized with the falling edge of ext. HD signal. To avoid this 1H jitter and delay, the falling edge of the ext. trigger pulse should be synchronized within 4.4 µsec. to the HD pulse. It can be the ext. HD in or the Internal HD out.

See cautions in Edge Pre-select Mode page 7.

3.The ext. trigger input is 75 Ohm terminated as factory setting. (R127 short and SW2-2 on). The

voltage level of the ext. trigger has to be 4.0 Vp-p ± 2.0 V. The duration should be more than 1 H negative going. >64 µsec. and < 60 msec. The input is AC coupled.

4.If the ext. trigger input and ext. HD input are from a source with TTL level, set SW2-1 and SW2-2 OFF for non-terminated. SW2-1 for HD signal, SW2-2 for ext. trigger pulse. See “7.2 SW2 on PK8057 Board”.

EIA (Non-interlaced / Field accumulation mode)

Pulse width control mode (for non-interlace only)

EIA : 1H = 63.5s

TRIG

 

 

 

 

 

1H more

 

 

1H

TRIG in

 

EXT HD

 

 

 

 

 

INT HD

 

 

 

 

 

INT VD

 

 

 

 

 

1.5H

9H

 

1H

1.5H

9H

EEN

 

 

 

 

 

Exposure time

12.5H

 

Exposure time

 

0.5H

0.5H

 

 

 

 

 

WEN

2H

9H

10H

 

 

 

 

 

CCD out

 

Effective pixels

 

 

 

 

 

 

 

 

 

 

No.10 to 251

 

 

 

Video out

20H

242H

20H

 

 

 

 

 

 

Blanking

Effective video

Blanking

 

 

CCIR (Non-interlaced / Field accumulation mode)

Pulse width control mode (for non-interlace only)

 

 

CCIR : 1H = 64s

 

TRIG

 

 

 

 

 

 

 

1H more

 

 

 

 

1H

TRIG in

 

EXT HD

 

 

 

 

 

 

 

INT HD

 

 

 

 

 

 

 

INT VD

 

 

 

 

 

 

 

1.5H

7.5H

 

 

7.5H

6.5H

1.5H

7.5H

EEN

 

 

 

 

 

 

 

Exposure time

 

16.5H

 

 

Exposure time

 

0.5H

0.5H

 

 

 

 

 

 

 

WEN

9H

7.5H

10H

 

14H

 

 

 

 

 

 

CCD out

 

 

 

Effective pixels

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.10 to 251

 

 

 

Video out

 

25H

 

287H

25H

 

 

 

 

 

 

 

 

 

Blanking

 

Effective video

Blanking

 

 

- 10 -

Image 11
Contents CV-M536/538/539 Declaration of Conformity Table of Contents Standard Composition GeneralMain Features Locations and Functions Pin Assignment Pin Multi-connector DC-IN/SYNCPin Multi-connector Trigger Functions and Operations Input/Output of HD/VD SignalEdge pre-select mode for non-interlace only EIA Non-interlaced / Field accumulation modePulse Width Control Mode Ccir Non-interlaced / Field accumulation modePulse width control mode for non-interlace only Start/Stop Trigger Mode CV-M536/538/539 EIA Ccir Long Time Exposure ModeCV-M536/538/539 Table for Shutter Time Mode SettingTable for SW 1 Setting SW2 on PK8057 Board Pixel Clock Output Jumper SettingsBoard PK8057 Side a Location of SW2 and JumpersBoard PK8054 Side B Adjustment of Video Signal Output Level Head External AppearanceCCU Spectral Sensitivity SpecificationsAppendix PrecautionsTypical CCD Characteristics Revision Revision E Serial No Users Mode Settings Users ModificationsUser’s Record Camera type CV-M536/538/539 Scanning system