JAI CV-M536, CV-M539, CV-M538 operation manual Start/Stop Trigger Mode

Page 12

CV-M536/538/539

6.3.3. Start/Stop Trigger Mode

The Start /Stop trigger will work in 3 modes:

1.Interlaced with frame accumulation.

2.Interlaced with field accumulation.

3.Non-interlaced with field accumulation.

The exposure time is controlled by the interval between the ext. trigger pulse and the ext. VD signal. The exposure starts at the first HD pulse after the falling edge of the ext. trigger, and stops at the rising edge of the VD pulse. The range can be within 1/77 to 1/10,000 sec.

The Start/Stop mode is a continuous mode where the VD signal must be given continuously. It is not possible to input ext. VD randomly.

For the interlaced modes 2 ext. trigger pulses should be applied for each frame. It is one for each field. In this way it is possible to have different exposure time for the 2 fields within an interlaced frame.

The difference between interlaced frame accumulation or field accumulation can be explained as follow. Both modes have 2 fields output in an interlaced frame. With frame accumulation the contents in the ODD and EVEN sync. fields will come from sensing field 1 and 2 on the CCD sensor. With field accumulation both ODD and EVEN sync. field will contain the signal from sensing field 1 and 2 added together.

Non-interlaced with field accumulation needs only 1 trigger pulse for each field.

To use this mode

Set:

SW1-1,2 and 3 to ON for 1/10,000 sec.

 

SW1-4 to OFF for normal shutter.

 

SW1-5 to ON for frame accumulation or OFF for field accumulation.

 

SW1-6 to OFF for 2:1 interlaced or ON for non-interlaced.

 

Jumper JP R127 on the PK8054 board OPEN

 

Jumper JP8, JP9, JP10 on PK8057 to SHORT

 

Jumper JP7 on PK8057 to OPEN

Input:

Ext. trigger to pin 5 on 6 pin multi connector. (Cannot be 75 Ohm terminated.)

 

Ext. VD to pin 7 on 12 pin multi connector.

 

Ext. HD to pin 6 on 12 pin multi connector. (If used).

 

HD/VD 75 Ohm termination is done with SW2-1 and SW2-2 on PK8057 board.

Refer to Timing Chart and Cautions on next page.

Detailed switch and jumper setting is described in “7. Mode Setting”.

For connections see “5. Pin Assignment”.

- 11 -

Image 12
Contents CV-M536/538/539 Declaration of Conformity Table of Contents General Standard CompositionMain Features Locations and Functions Pin Multi-connector DC-IN/SYNC Pin Multi-connector TriggerPin Assignment Input/Output of HD/VD Signal Functions and OperationsEIA Non-interlaced / Field accumulation mode Edge pre-select mode for non-interlace onlyCcir Non-interlaced / Field accumulation mode Pulse Width Control ModePulse width control mode for non-interlace only Start/Stop Trigger Mode CV-M536/538/539 Long Time Exposure Mode EIA CcirCV-M536/538/539 Mode Setting Table for SW 1 SettingTable for Shutter Time SW2 on PK8057 Board Jumper Settings Pixel Clock OutputLocation of SW2 and Jumpers Board PK8054 Side BBoard PK8057 Side a Adjustment of Video Signal Output Level External Appearance CCUHead Specifications Spectral SensitivityPrecautions Typical CCD CharacteristicsAppendix Users Mode Settings Users Modifications User’s RecordCamera type CV-M536/538/539 Scanning system Revision Revision E Serial No