JAI CV-M539, CV-M536 Ccir Non-interlaced / Field accumulation mode, Pulse Width Control Mode

Page 10

CV-M536/538/539

CCIR (Non-interlaced / Field accumulation mode)

Edge pre-select mode (for non-interlace only)

 

 

CCIR : 1H = 64s

 

TRIG

 

 

 

 

1H

TRIG in

 

1H more

 

 

 

 

 

EXT HD

 

 

 

 

 

 

 

INT HD

 

 

 

 

 

 

 

INT VD

 

 

 

 

 

 

 

1.5H

7.5H

 

 

7.5H

6.5H

1.5H

7.5H

EEN

 

 

 

 

 

 

0.5H

Exposure time

 

16.5H

 

 

Exposure time

 

0.5H

 

 

 

 

 

 

 

WEN

9H

7.5H

10H

 

14H

 

 

 

 

 

 

CCD out

 

 

 

Effective pixels

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.10 to 251

 

 

 

Video out

 

25H

 

287H

25H

 

 

 

 

 

 

 

 

 

Blanking

 

Effective video

Blanking

 

 

6.3.2. Pulse Width Control Mode

The pulse width control mode will only work in non-interlaced field accumulation mode.

The exposure is controlled by the low period of the ext. trigger pulse. The exposure starts at the first HD pulse after the falling edge of the ext. trigger pulse. The exposure ends at the first HD pulse after the rising edge of the ext. trigger. The Shutter can be controlled to be within the range from >1H (>64 µsec.) to <60 msec. The AC coupling causes the upper limit.

EEN (Exposure ENable) pulse and WEN (Write ENable) pulses are generated and output from the camera.

The EEN pulse indicates the exposure time. The EEN pulse is output from pin 2 of the 6-pin multi connector. The signal level is 4.0 Vp-p from a 75 Ohm source.

The WEN pulse indicates the time period of the effective video signal output and is useful for the timing and interfacing of external devices such as frame grabbers. The WEN pulse is output from pin 6 of the 6- pin multi connector. The signal level is 4.0 Vp-p from a 75 Ohm source

The video must be read out before a new trigger can be applied. The interval between trigger pulses must be longer than the time for 1 field + the shutter time. It is the limit for the field rate.

To use this mode

Set:

SW1-1, 2 and 3 to OFF

 

SW1-4 to ON for ext. trigger shutter

 

SW1-5 to OFF for field accumulation

 

SW1-6 to ON for non-interlaced

 

JP12 on PK8057 to OPEN

Input:

Ext. trigger to pin 5 on 6-pin multi connector.

 

Ext. HD to pin 6 on 12-pin multi connector. (If used).

 

75 Ohm termination is done with SW2-1 (HD) and SW2-2 (ext.trigger) on PK8057 board.

Refer to Timing Chart and Cautions on next page.

Detailed switch and jumper setting is described in “7. Mode Setting”.

For connections see “5. Pin Assignment”.

- 9 -

Image 10
Contents CV-M536/538/539 Declaration of Conformity Table of Contents General Standard CompositionMain Features Locations and Functions Pin Multi-connector Trigger Pin Multi-connector DC-IN/SYNCPin Assignment Input/Output of HD/VD Signal Functions and OperationsEIA Non-interlaced / Field accumulation mode Edge pre-select mode for non-interlace onlyCcir Non-interlaced / Field accumulation mode Pulse Width Control ModePulse width control mode for non-interlace only Start/Stop Trigger Mode CV-M536/538/539 Long Time Exposure Mode EIA CcirCV-M536/538/539 Table for SW 1 Setting Mode SettingTable for Shutter Time SW2 on PK8057 Board Jumper Settings Pixel Clock OutputBoard PK8054 Side B Location of SW2 and JumpersBoard PK8057 Side a Adjustment of Video Signal Output Level CCU External AppearanceHead Specifications Spectral SensitivityTypical CCD Characteristics PrecautionsAppendix Camera type CV-M536/538/539 Scanning system Users Mode Settings Users ModificationsUser’s Record Revision Revision E Serial No