Master Level Indicator

Front Panel Display

Master Level Indicator

This field displays the system master level in dB. It is calculated as relative gain (displayed from 0 to 99.9) minus 99.9 plus GAIN (as set in the OPTIONS menu).

For example, if the GAIN option is set to 3 dB and the front pane l master level dis play reads 87.5 dB, this field will display 87.5 - 99.9 + 3.0 = -9.4 dB.

Correction menu option

Move the cursor to the DRC-RCS (4) option and press the “ ENTER” button to enter the main dynamic room correction menu.

Parametric EQ menu option

Move the cursor to the PAR EQ (5) option and press the “ENTER” button to enter the main parametric EQ menu.

Note: An EQ preset must be enabled from the main screen for the PAR EQ menu to be active. If the EQ preset is set to “BP”, the PAR EQ controls are disabled.

Output sampling frequency indicator

This displays the currently selected output sampling frequency. The output sam- pling frequency is can be modified in the “OUT-FS” general menu option.

Input sampling frequency indicator

This displays the sampling frequency of the currently selected digital input. The RCS 2.2 XP will automatically detect input signal presence and display its sam- pling frequency.

RCS 2.2 XP operating mode

This displays the systems operating mode. The operating mode can be modified from the “MODE” main menu option.

MONO mode indicator

When the MONO option in the MODE m enu is set to ON, this field displays an ‘M’ If the MONO option is set to OFF, this field is not visib le.