without a n external computer interface.

Front Panel > Correction Menu

MSR menu Use th is menu to perform room response measurments directly from the front panel,

without a n external computer interface.

CAUTION

Your 2.2 XP is factory configured to measurement parameters as displayed above. The

MSR MIC CAL option should be turned ON and tjhe MIC FILE field should display the

microphone serial number as printed on your microphone.

MSR MIC CAL. When this option is set to ON, the room correction algorithm will apply the microphone calibration fi le to the measurement data. When this option is set to OFF, the microphone calibration fi le is ignored.

MIC FILE. This fi eld displays the microphone fi le name used to perform micro- phone calibration. The microphone calibration fi le data is saved in 2.2 XP internal memory. For more details on how to transfer microphone calibrations fi le to 2.2 XP memory, please refer to the Microphone section of the PC software manual.

AVG This is a very important measurement parameter. It equals the number of measurements that are averaged prior to being saved. The averaging process reduces the effects of random environmental noise. Typical Average values go from 10 to 30.

DELAY. If you do not want to be in the room while measurement is in progress, set this parameter to a few seconds to allow you to exit the room. For example, if DELAY = 10 the system will wait for 10 seconds before it starts pulsing.

PULSE. This parameter sets the relative level of the output measurement pulse.

Minimum level is 1% and maximum level is 100%.

FILE. Use this option to assign a File number to the measurement you are just about to perform. At the end of the measurement process, the measurement data for all four channels will be saved in the selected File number. Tact-2.2 XP sup- ports up to seven measurement fi les. In another words you can save up to seven different measurements in 2.2 XP internal memory.

Use L, R, SL and SR options to select (enable) a channel for measurement. Channels are labeled as L for left, R for right, SL for subwoofer left and SR for subwoofer right channel. Selected (enabled) channels are marked by a rectangle. To select or deselect a channel place the cursor over desired channel and press ENTER button.