Hasselblad H4D200MS user manual  REMOVING and Attaching the Viewfinder,  EYEPIECE Adjustment

Page 24

 REMOVING AND ATTACHING THE VIEWFINDER

To remove, grasp the viewfinder in the right hand and while depressing the viewfinder release button, lift the rear of the viewfinder up and away from the camera body.

To attach, hold the viewfinder at a slight angle and rest it on the top of the camera. Slide the viewfinder forward until the front locating pin is in position in the recess in the front edge of the viewfinder screen aperture on camera body. Press the rear part of the viewfinder firmly downwards until it clicks into place.

Ensure that both sides of the viewfinder are seated correctly and that it has been firmly attached and locked into posi- tion. Failure to do so could cause an intermittent malfunc- tion if the databus interface connections between the view- finder and camera body are not positively secured. Avoid lifting the camera by the viewfinder alone.

2

1

 EYEPIECE ADJUSTMENT

No corrective lenses are needed to adjust the eyepiece to suit most requirements. The diopter range is from -5 to +3.5D. Eyeglass wearers can rapidly and accurately change the settings according to whether they wish to wear eyeglasses for view- ing or not.

Personal eyepiece adjustments can be carried out by pointing the camera at the sky or similar smoothly toned area. While holding the camera in your left hand, you can with your right thumb turn the adjustment wheel until the markings on the viewfinder screen reach the optimum sharpness for your eyesight.

If you normally wear eyeglasses for distance viewing and intend to wear them for ­camera use then do not remove them for the above procedure. If, on the other hand, you prefer to remove your eyeglasses for camera work, then repeat the above procedure without wearing your eyeglasses.

 RUBBER EYE CUP

Two rubber eye cups are available for the H5D. The one sup- plied is suitable for users who do not intend to use eyeglass- es when photographing. The second shorter eye cup is for those who either prefer to position their eye further from the viewfinder and those who wish to wear eyeglasses.

The eye cups can be rapidly changed by a Hasselblad Autho- rized Service Center.

 ACCESSORY CONNECTION

There are two accessory-­ retaining screw threads (M5) as well as a databus connector on the left hand side of the camera body, ­protected beneath a cover. The cover can be removed by firstly lifting the left hand edge a little and then sliding the cover to the left, as in the illustration.

 PC-CONNECTOR

A PC connector for non TTL- flash synchronisation is located on the left side of the body. It is protected by a captive rubber plug.

Lift this edge of the cover first

24

Image 24
Contents Page Introduction Page 50MS & 200MS models also feature Index General overview Controls and displaysFirmware Updates Computer System RequirementsPARTS, COMPONENTS, Buttons and Controls Overview Exposure compensation button  Exposure Display buttonGrip Buttons and Controls ExampleCamera Body Buttons and Controls True Focus buttonSensor Unit Menu / Exit buttonViewfinder LensesDisplay Information − Overview Viewfinder InformationSensor Unit Display and Controls − Overview  BUTTONS and Scroll Wheels GRIP Information  SPIRIT LevelGrip Display − Overview Typical Grip Display‘aperture priority’ mode Viewfinder Display − OverviewSome Examples of Various Viewfinder Displays SecondCustomizable Buttons Function Options Stop DownCamera Configuration in Phocus  CREATING a ProfileMenu button P1 / P2 setting option access ShortcutsGeneral  RECHARGEABLE Battery Grip  FITTING and Removing a Battery BATTERY Charger  CARRYING Strap CHARGING the Battery  BATTERY Life  BATTERY Status POWER Modes  AUTOMATIC Settings VIEWFINDER Screen  RE-ACTIVATION from Display OFF or Sleep Modes EYEPIECE Adjustment  ACCESSORY Connection PC-CONNECTOR  REMOVING and Attaching the Viewfinder USING Compact Flash Memory Cards  PROTECTIVE Base Plate INSERTING a CF Card  REMOVING a CF Card FORMATTING Cards  FORMAT Button FORMAT VIA Sensor Unit  CAREANDMAINTENANCEOFSENSOR Unit  SENSOR Unit Introduction REMOVING and Attaching Sensor Unit Do not touch the exposed CCD/filter with your fingers CLEANING the Sensor Filter  CONNECTING to a Computer TETHERED to a Computer with Phocus Running 3FR Jpeg Features in Phocus PhocusPlus Lenses Focus Modes  Focusing Distance Calculation  ATTACHING a Lens REMOVING a Lens  FRONT Lens CAP INFRARED Focus Settings  STOP Down / DEPTH-OF-FIELD Preview FOCUS Assist HCD lenses were formulated for use with the smaller size  AUTO / Manual Focus Setting  MANUAL Override in Autofocus Mode AUTOFOCUS Override in Manual Mode  MANUAL Focus SINGLE Shot  CONTINUOUS TRUE Focus  TRUE Focus and Absolute Position Lock Ca.2.5 m FOCUS Checking in BROWSE, Preview or True Focus Mode  TRUE Focus and Camera HandlingMenu Settings Custom Options # Menu Settings Custom OptionsFour True Focus Methods Activated by Shutter Release Button True Focus RetainedActivated by True Focus Button Autofocus Deactivated Activated by AN Assigned Button Manual Focus RetainedExposure Control  ISO & White Balance  ISO & White Balance on Grip LIGHT Metering Modes  EXPOSURE Setting Modes  SELECTING Metering / Exposure Setting Modes MANUAL Exposure M  OVEREXPOSURE Indicator  AUTOMATIC Exposure A, S, P, PV AE- L Button Metered area reads ‘Zone 8’ FIXED Exposure Compensation Setting  EXPOSURE Compensation / Quick AdjustNavigating the Menus ISO Basic Description of Sensor Unit Menu Items OVERVIEW of Navigating Menu and Settings on Sensor Unit Sound. OVERVIEW of Navigating Menu and Settings on Grip SavedNot Saved Previews Browsing  PREVIEW Modes Standard preview FULL Details Mode  FULL-SCREEN Mode BROWSING  ZOOMING in and OUTSensor Unit Settings Basic Overview of Sensor Unit Menu  NAVIGATION ISO Setting on Sensor Unit  WHITE Balance Setting on Sensor UnitPresets Sensor Unit Menu ISOWhite Balance Setting by Using a ‘GREY CARD’ Image Format Setting IMAGE Format Sensor Unit Menu White Balance ManualSettings Storage Storage DELETE  FORMATSettings Settings User Interface  SOUNDSensor Unit Menu Settings User Interface Sound Audio FeedbackSensor Unit Menu Settings User Interface Date & Time Sensor Unit Menu Settings User Interface Display DATE & Time  DISPLAYSettings Custom Options Sensor Unit Menu Settings Custom Options P1 / P2P1 and P2 Button Function Options 10 sec, 20 sec, 30sec, 60 sec SleepSettings Service  SERVICESensor Unit Menu Settings Custom Options Image Orientation Sensor Unit Menu Settings Custom Options Show PreviewSettings about Sensor Unit Menu Settings about ABOUT Normal at default setting Repro at default settingUser icon Grip Menu Settings  GENERAL Overview of Grip Menu System status Drive SETTINGS  SELF TimerSelf Timer Setting Bracketing Setting BracketingExample Interval Setting IntervalSecond 1 hour Settings Custom Options Custom Options on Grip CUSTOM Options on Grip 10s 20s 30s 60sStep Delete Grey bal ex Spirit Level Rear Info Screen NoneNo Yes On OffHalf press Always Off Ext flash Camera OffAll controls Wheels Off Exit StayNone 2s 10s 60s Interval time Normal Light meterMs 100 ms 200 ms None 25 ms Image Info Setting Settings Image InfoSettings Date & Time System Status Disclosure Single and Continuous Setting Camera active mode DRIVE Profiles Profiles Making a Profile USING Profiles  CHANGING a Profile NameFlash / Strobe Flash / Strobe General ACCESS to Controls Using the integral flash INTEGRAL Flash  SEPARATE Flash Unit Connection  FLASH Measure of Separate Flash UnitTo use flash measure Accessories Connectivity Diagram HC Lens Range Optional Accessories HVM waist level viewfinderOptional HC Lens Accessories HVM correction lens holderMulti Shot Appendix H5D Camera Specifications H5D-40 H5D-50 H5D-60 H5D-50MS H5D-200MSAll models Default Settings ‘DEFAULT’ Profile GeneralStopped down one stop with True Exposure mode OFF True ExposureAutomatic Exposure P & PV Mode ModePROBLEMS, Equipment Care & Service ServiceEquipment Care 101 Copyright Victor Hasselblad AB All rights reserved 103