Sennheiser W300 manual Care and maintenance, For multi-channel operation

Page 37

... for multi-channel operation

y For multi-channel operation, you can only use the channels in a channel bank. Each of the channel banks “1” to “8” accommodates eight factory- preset frequencies which are intermodulation-free. For alternative frequency combinations, please refer to the enclosed frequency table. The freely selectable frequencies can be selected via the “TUNE” menu and can be stored in the channel bank “U”.

y When using several transmitters simultaneously, interference can be avoided by maintaining a minimum distance of 20 cm between two transmitters.

yUse special accessories for multi-channel applications (see “Accessories“ on page 43).

Care and maintenance

Use a slightly damp cloth to clean the units from time to time.

Note:

Do not use any cleansing agents or solvents.

To clean the SKM 300 G2’s sound inlet basket, proceed as follows:

Unscrew the sound inlet basket (turn counterclockwise) and remove it.

Remove the foam insert.

Use a slightly damp cloth to clean the sound inlet basket from the inside and ouside.

Reinsert the foam insert.

Replace the sound inlet basket on the SKM 300 G2 and screw it tight (taking care not to loose the colored identification ring).

37

Image 37
Contents W300 Thank you for choosing Sennheiser Contents Channel bank system Evolution wireless series ew 300 G2System variants Safety instructionsAreas of application Delivery includesEM 300 G2 rack-mount receiver Overview of operating controlsSK 300 G2 bodypack transmitter SKM 300 G2 radiomicrophone Indications and displays on the receiver Transmitter battery status indicationMute display Modulation displayIndications and displays on the transmitters Operation and battery status indicationDiversity display Button backlightingDisplay backlighting AF peak indication SK 300 G2 onlyConnecting the mains unit Connecting the antennasPreparing the components for use Mounting the receiver feetService interface Connecting the amplifier/mixing consoleRack adapter and antenna mount Bottom sides of the receivers Inserting and replacing the batteries Connecting the microphone/line cableInserting and charging the accupack Positioning the microphones Attaching the microphonesAttaching the bodypack transmitter to clothing Changing the microphone head Switching the components on/off Using the componentsSwitching the rack-mount receiver on/off Switching the bodypack transmitter on/offMuting the transmitters Activating/deactivating the lock modeMuting the SK 300 G2 bodypack transmitter Muting the SKM 300 G2 radiomicrophoneButtons Operating menuOverview of menus Storing a setting Adjusting a settingWorking with the operating menu Getting into the operating menuExiting the operating menu MHz Operating menu of the receiver01 786.300 MHz Main Frequency Low HighOff PilotOperating menu of the transmitters ExitBank Switching between channel banks Adjustment tips for the operating menuSwitching between the channels in a channel bank Displaying the last scan result Scanning the channel banks for free channels EM 300 G2 onlyStarting the scan Releasing locked channelsMulti-channel operation Adjusting the sensitivity transmitters onlyAdjusting the squelch threshold EM 300 G2 only Adjusting the audio output level EM 300 G2 onlyIMPORTANT! Notes EM 300 G2 rack-mount receiver Selecting the standard displayEntering a name Loading the factory-preset default settingsExiting the operating menu Adjusting the contrast of the graphic display EM 300 G2 onlyError checklist If problems occurRecommendations and tips For multi-channel operation Care and maintenanceAdditional information Wireless transmission systemsHDX noise reduction Diversity reception SquelchPilot tone squelch Field strength-dependent squelchSystem SpecificationsReceiver Transmitters Onnector assignmentMicrophones Microphone headsPage Accessories Manufacturer declarations Warranty regulationsCE Declaration Conformity Batteries or rechargeable batteries