Modes and Initial Switch Settings
5.1 Modes and Initial Switch Settings
With this unit it is possible to switch the operating modes to suit the intended use. All mode settings can be set with switches. Table 5±1 summarizes the modes and initial switch settings.
Table 5±1. Modes and Initial Switch Settings
Function | Initial Setting | Setting Switch |
|
|
|
Shutter speed switch | Ð | Rear panel SW1 |
Gain (sensitivity) | Fixed gain | Rear panel SW2 |
- Fixed gain |
|
|
- Variable gain |
|
|
- AGC |
|
|
Electronic shutter | OFF | Rear panel SW3 ± 1, 2 |
- OFF | 1/60 seconds |
|
-continuous shutter
-Random shutter (V fixed)
-Random shutter (V reset)
-VI shutter (optional exposure period)
Internal/External Sync | Internal sync | Rear panel SW3 ± #, 4 |
Interlace | Rear panel SW3 ± 5 | |
Sync signal input/output impedance | 75Ω | Rear panel SW4 |
- 75Ω/150Ω/100kΩ |
|
|
Gain variable volume | Ð | Rear panel VR1 |
Sync signal input/output | Input | Clock board SW1 |
Optional input/output shutter | monitor out | Clock board S1 |
- Shutter monitor output |
|
|
- Pixel clock output |
|
|
γ switch characteristics | γ = 1 | Process board SW1 |
- γ = 1/0.45 |
|
|
Output signal coupling | AC combined output | Process board SW4 |
- AC combined out/DC output |
|
|
Outline emphasis circuit (PIH only) | OFF | Process board SW2 |
|
|
|
Initial Settings |