Siemens CCMX1315-LP configurationmanual Specifications, Image System Description

Page 9

Specifications

3

Specifications

 

 

 

 

 

 

 

 

Image System

Description

 

Image sensor

1/3” progressive ExviewHAD CCD, 1.3 Megapixels

 

Effective pixels

1280 (H) x 960 (V)

 

Image compression method

Motion JPEG/ MPEG4

 

Image frame rate

SXGA: 1280 x 960 at 12.5 fps max.

 

 

 

VGA: 640 x 480, QVGA: 320 x 240 at 25 fps max

 

Cropping window

Simultaneous video transmission of up to 5 independent cropping windows, free configuration

 

 

 

in size and position at 5 fps max. (MJPEG mode only)

 

Video out(for installation)

1 Vpp, 75 Ohm BNC composite video, (either CVBS or IP video selectable by switch)

 

Electronic

 

 

 

 

 

Sync system

Internal

 

Lens mount

CS mount

 

Gamma correction

0.45/1.0

 

 

 

Min illumination

Colour 0.4 lx (F1.2, AGC ON), BW 0.2 lx (AGC ON) (CCBS1315-LP only)

 

White balance

Auto (2500 K - 10000 K) / Manual (1500 K - 15000K) / Preset

 

Electronic shutter

1/25 - 1/10,000 sec; support long shutter up to 4 s

 

BLC

 

On/off, BLC1 - BLC6

 

Audio

 

Two way Audio; Full duplex, G.726 selectable

 

Alarm

 

1x Alarm in, 1x Alarm out, 1 x B/W switch in

 

RS-485

 

Yes

 

SD card slot

Support up to 2 GB SD card (2 GB SD-card included at delivery)

 

Internal Microphone

Yes

 

Motion detection

MD window selected by mouse & 3 level sensitivity

 

Power Supply

 

 

 

 

Power requirement

12 V DC / 24 V AC, 50 Hz or PoE

 

Power consumption

CCMC1315-LP: < 7 W,

 

 

 

CCMS1315-LP: < 8.5 W

 

Power connector

Screw-less terminal block

 

Environment

 

 

 

 

Operating temperature

-10 to +50

 

 

 

 

Operating humidity

80 % RH

 

Storage temperature

-20 to +60

 

 

 

 

 

 

 

Network

 

 

 

 

 

Ethernet

 

1 x 10/100 based-T Ethernet connection for LAN/WAN

 

Internet protocol

TCP/IP, UDP, HTTP, SMTP, DNS, DHCP, NTP, ARP, ICMP, DDNS, FTPc, FTPs, DHCPc,

 

 

 

RTSP, RTCP, RTP, IGMPv3

 

Security

 

Multiple password for Admin, Advanced Users and Users

 

Control interface

IE browser 6.0 or above

 

I/O connector

 

 

 

 

Network port

RJ45 with control LED

 

Video output

BNC (CVBS out selectable by switch)

 

AI lens connector

1 x 4 pin jack (located on side)

 

Audio in & out connector

3.5 mm phone jack

 

Alarm connector

2 x alarm in / 1x alarm out

 

Power connector

3 pins spring terminal block

 

LED

 

Orange stand for Network online, Green stand for system ready

 

RS485

 

2- pin spring terminal (for Telemetry Receiver using SCU protocol)

 

Mechanism

 

 

 

 

Dimensions (LxWxH)

150 x 66 x 64 mm

 

Weight

 

0.55 kg

 

 

 

9

 

 

 

 

 

 

Siemens Building Technologies

 

 

 

 

Fire Safety & Security Products

01.2009

Image 9
Contents Configuration Manual Trademarks CopyrightContacting us Training coursesContents 10.1 Page General safety precautions SafetyInstallation Target readersMeaning of the hazard symbols Meaning of the signal wordsCleaning Damage due to unsuitable mounting locationEuropean Directive 2004/108/EC Electromagnetic Compatibility EU directivesImage System Description SpecificationsOrdering data Package contentsCamera part definition Camera part and connector definitionConnector pin definition Precautions Installing the cameraPower adaptor SD memory cardSpecifications Setting network camera environmentSwitch Concept of the network cameraConnecting the camera and personal computer via network Connection configurationIP address Connecting camera and personal computer Using the camera search application IpFinder Setting up IpFinderClick the Home page of selected device button Ssdp Simple Service Discovery Protocol / network protocol Using the camera search application Web cam IP managerPreparations before displaying z Enable cookies Administrator Log-inLog-in screen Viewing and listeningLog-in the camera Browser setting when proxy server is usedComponents of unit home Camera Image screenConfiguration Image modeCompression Multicast Streaming Unicast StreamingHow to operate Rtsp For example rtsp//192.168.0.194554/livestream Select Open URLNetwork settings Basic SettingsNetwork Settings in the Configuration menu FTP Server Ddns SettingsCamera Basic setting Select Image Parameters in the Configuration menuImage parameters Image colour Picture Camera-mask zone settingsCamera cropping settings Configuration Camera OSD settings AlarmExternal digital input Motion detection settings Audio Event Alarm outputRecord FTP recordingFTP recording conditions FTP Server Settings Server 1 SD Card Back Up if FTP Fail Connecting methodSD recording Configuration Authentication setting Condition settings for sending e-mail by scheduleEmailing recording Condition settings for sending e-mail by alarm Condition settings for sending e-mail by motionMail to Address List NAS recording Configuration Audio Audio inputAudio output Date/Time Access protection Administrator Functions AdministratorPassword User listFirewall IP Address FilterForbidden Ports Update SettingSystem Forbidden ProtocolConfiguration Temperature BackfocusRemote 11 Log Event LogInformation Audio record setup NAS player setupUtility program application Playing back NAS filePerform firmware update in the following sequence Firmware update setupDisposal MaintenanceJpeg LED Keyword indexKeyword index A6V10236123