Kodak P461 manual Technical Spec ifications, Freq uently Asked Questions, 5x5, 4x6

Page 21

Technical Spec ifications

 

Specification

KODAK P461 Personal Photo Scanner

 

 

Photo: Up to 4.1 x 12” (Common use: 3.5x5” and 4x6” photo)

 

Media Type

Filmstrip: 35 mm Color / B&W Negative filmstrip

 

 

Slide: 35 mm Color / B&W Mounted Slide

 

Common Document Size

3.5”x5”, 4”x6” and 4x11”

 

 

 

 

Actual Feed Slot Size

up to 4.1” x 12”

 

Length: 12 inches (304.8mm)

 

Width 4.1 inches (105mm)

 

Output file formats

 

JPEG with compression (4:2:2)

 

Resolution (fixed)

 

Photo: 600x600 dpi (default) and 300x300 dpi

 

 

Filmstrip: 1200 x 1200 dpi

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interfaces

 

 

Memory Cards

 

Refer to Supported Memory Cards (pg 7)

 

 

 

USB

 

 

Mini USB port compatible USB 2.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USB Mass Storage Supported

 

WINDOWS 2000 / XP / VISTA / WINDOWS 7

 

 

 

 

 

 

 

 

 

Power

Batteries

Input 100-240V AC, 50/60 Hz, Output 5V, 1A

Takes four AAA (UM-4) batteries (not included). Recommend rechargeable batteries for optimal number of scans. Rechargeable battery life in 600dpi averages 100+ scans per charge. Actual battery life may vary based on usage.

 

Photo feeding

 

Sheet-fed type (single-pass)

 

 

Twin roller design

 

 

 

 

 

 

 

 

 

 

Transparency feeding

 

 

Filmstrip fed with Filmstrip Guide Adapter

 

 

 

Mounted Slides fed with Slide Holder

 

 

 

 

 

Dimensions

 

2.25” (L) x 10.5” (W) x 2” (H)

 

 

61.7 mm (L) x 269.3mm (W) x 52 (H) mm

 

 

 

 

 

 

 

 

 

Net weight

 

 

0.75 lbs (455g)

 

 

 

 

 

 

Operating Temperature

 

15ºC ~ 35ºC (59oF~95oF);

 

Operating Humidity

 

20% RH ~ 70% RH

 

 

 

 

 

Storage Temperature

 

-20ºC ~ 60ºC (59oF~95oF);

 

Storage Humidity

 

10% RH ~ 90% RH

 

 

 

 

 

Freq uently Asked Questions

Q:What would cause strange lines on the scanned picture or unclear?

A:Check the following:

Are there scratches on the original, or is the original clean? Remove any stains or dust from the original before scanning.

Has the scanner been used for a long period of time without cleaning and calibration? Follow the instructions for "Cleaning the scanner" on page 18 and “Calibrating the scanner" on page 19, and then try again.

Q:Why isn’t the scanned filmstrip image rotating properly?

A:The current “auxiliary” OCR capability has difficulty distinguishing the direction of some numbers, (i.e.,“6”, “9”). If the number’s position is near the edge of the filmstrip, it can easily be worn out or damaged, and then it can’t be detected in the expected position, or meet the required conditions causing the Auto Mirror/Flip function to be disabled (see page 10). Please follow the indicator on the filmstrip guide adapter to re-scan the filmstrip.

Q:How do I clear an original that is stuck halfway in the feed slot?

A:Press the Power button; the scanner ejects the original so you can remove the jammed original from the feed slot in photo/slide scanning, and Transparency output slot in filmstrip scanning.

Customer Support: http://www.pandigital.net/kodaksupport 21

Image 21
Contents P461 Table of Contents Important Safety Precautions Read This FirstWhat’s in the Box Scanner Ov erview Introducti onFront View Name Function/ DescriptionScanner Indica tor Lights Rear ViewBottom View Unsuitable Suitabl e and Unsuitable Original Types SuitableSdhc Supported M emory Ca rdsOrientation of the Original and Scanned Picture Operating the Scanner Preparation and Initial SetupSetting the Scanning Resolution Turning on the ScannerScanning a Photo Auto Image Mirror/Flip Scanning 35mm Negatives and SlidesFeeding Filmstrips Scanning Mounted Slides Automatic Image CroppingCropping size as measured on the original Connec t Sca nner to a Computer System RequirementsFor Windows Vista Users For Windows 7 Users For Windows XP UsersFor MAC Users Scanned Picture Naming ConventionSca n P C Softwa re for Kodak P ersona l P hoto Sca nners Install Scan PC SoftwareFor MAC users Scan PC Software is not supported on the MAC OSUninstall the Scan PC Software Using the Scan PC SoftwareLaunch Scan PC Software Manually Kodak Easyshare Softwa re for PCLaunch Kodak Easyshare Software Install Kodak Easyshare SoftwareSca nner Ma intena nc e Cleaning the Scanner Uninstall the Kodak Easyshare SoftwareClean the Outer Casing Clean the Photo Image SensorClean the Transparency Image Sensor Clean the RollerCalibra te the Scanner Storing the Sc a nner Technical Spec ifications Freq uently Asked Questions5x5, 4x6 Limited Wa rranty Pgra ding Softwa re a nd Firmwa reWaste Electrical and Electronic Equipment/Battery disposal FCC StatementFCC Part 15 Information Français Introduction Vue générale du Scanneur Logiciel Kodak Easyshare pour PCUtilisation du Scanneur Limite de la garantieVeui llez d’abord l i re ces instr uctions Précautions importantes de sécuritéContenu de l’emballage Vue généra le du S ca nneur Ntro du cti onVue de face NomVue arrière Vue de basNom Fonction/ Description Ndica teur lumineux du s ca nn eur Documents originaux inadaptés’état/carte Cartes mémoire supportées Orientati on de la photo original e et de l’image sc ann ée Installation des PilesConfiguration de la Résolution du Scannage Mettre le scanneur en marcheScanner une photo Image en auto-miroir/auto-inversé Scruter 35 mm Négatifs et GlisseInsertion des films fixes Diapositives encadrées de scannage Recadrage automatique d’imageTaille de recadrage telle que mesurée sur loriginal Connec ter le S ca nneur à un P C Configuration nécessairePour les utilisateurs de Windows XP Pour les utilisateurs de Windows VistaPour les utilisateurs de Windows Lettre du disque durProtocole de dénomination des photos scannées Pour les utilisateurs de MACPour déconnecter de façon sûre le scanneur du PC Pour Utilisateurs WindowsDésinstaller le logiciel Scan PC Pour installer le logiciel Scan PCPour utiliser le logiciel Scan PC Lancer le logiciel Scan PC manuellementOgi ciel KO DAK EAS YS H AR E pour P C Pour installer Logiciel Kodak EasyshareSystème requis Launch Logiciel Kodak EasyshareEntreti en du s ca nneur Nettoyage du scanneur Désinstaller le logiciel Kodak EasyshareNettoyage du boîtier Nettoyer le Capteur d’Image PhotoComment nettoyer le rouleau Nettoyer le Capteur Image de TransparenceUtilisati on de Pi les Comment calibrer le scanneurRa nger le S canneur Pécifica tions tec hniquesSi le Scanneur dégage de la chaleur ? Ques tions fréq uentesInformation sur la Partie 15 de la FCC Déclaration FCCPage Español Lea esto antes de comenzar Software Kodak Easyshare para PCIntroducción Descripción del Escáner Tarjetas de memoria compatiblesLea esto a ntes de co menzar Precauciones de seguridad importantesArtículos incluidos De s cr i pci ó n de l Escá ne r T r o d u c c i ó nVista frontal Nombre Función/ DescripciónVista inferior Vista posteriorUces i ndica do ra s del Es cán er No adecuadosEstado/Tarjeta  Sdhc Ta rjeta s de mem oria c om pat iblesO de l Es cá ne r Preparación y Arreglo Inicial Configuración de la resolución de escaneo Encendido del EscánerEscaneado de una fotografía Invertir/Rotar imagen automáticamente Escudriñar 35 Negativos de Mm y DeslizaAlimentación de tiras de película Escaneado de diapositivas montadas Recorte automático de imágenesTamaño de recorte según se mide en el original Requisitos del sistema Cone c ta r e l Es c á ner al P CPara usuarios de Windows XP Para usuarios de Windows VistaPara usuarios de Windows Para usuarios MACDesconexión segura del Escáner de la PC Convención de nombres de imágenes escaneadasPara usuarios Windows Para usuarios MACUso del software Scan PC Instalar software Scan PCLanzar manualmente el software Scan PC Desinstalar el software Scan PCInstalación de Kodak Easyshare Software Tw a r e KOD AK E AS YS HA RE p a ra P CDesinstalar el software Kodak Easyshare Lanzamiento de Kodak Easyshare SoftwareMantenimiento del Es cá ner Limpieza del Escáner Limpieza de la carcasa externaLimpieza del sensor de imágenes de fotos Limpieza del sensor de imágenes de transparenciasLimpie el rodillo Calibra ci ón de l Escáner Uso de bateríasCóm o gua rda r el Es cá ner Es pe ci f i ca ci one s t é cni ca s Reguntas frecuentesX 5 , 4 x 6 y 4 x ¿El escáner debe estar caliente si se lo toca? Información del apartado 15 de FCC Normativas FCC