Minolta 5600HS (D) appendix Performance

Page 39
Shutter speed

PERFORMANCE

Guide number

Normal flash (ISO 100)

 

Flash Coverage Setting (mm)

Power level

17

24

28

35

50

70

85

1/1

18

30

32

38

44

50

56

1/2

12

21

22

26

31

35

38

1/4

9

15

16

19

22

25

27

1/8

6.4

10

11

13

15

17

19

Flash coverage

 

Flash Coverage Setting (mm)

Flash coverage

17

24

28

35

50

70

85

Top-bottom (° )

115

60

53

45

34

26

23

Left-right (° )

125

78

70

60

46

36

31

1/16

4.5

7.5

8

9

11

12

13

1/32

3.2

5.3

5.7

6.7

7.8

8.8

9.7

 

 

 

 

 

 

Wireless flash (ISO 100)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flash Coverage Setting (mm)

Power level

17

24

28

35

50

70

85

1/1

14

25

26

30

35

41

42

HSS flat flash (flash with HSS, ISO 100)

Flash Coverage Setting (mm)

17 24 28 35 50 70 85

Continuous flash perfor- mance

AF illuminator

40 continuous cycles of 5 flashes per second (Normal flash, power level 1/32, nickel-metal hydride battery)

Automatic flash at low contrast and low brightness For wide focus area

Approximate operating range (with Maxxum/Dynax 7)

AF mid 3 areas: 0.5 - 10m (24 - 105mm)

AF top-bottom 6 areas: 0.5 - 5m (35 - 105mm)

1/250

6.7

12

13

15

17

19

22

1/500

4.5

8.6

9.5

10

12

13

16

1/1000

3.5

6

6.7

7.5

9

9.5

11

1/2000

2.4

4.3

4.5

5

6

6.7

8

1/4000

1.7

3

3.5

3.7

4.5

4.7

5.6

1/8000

1.2

2.1

2.4

2.5

3

3.5

4

Flash control

Size

Weight

Flash control using pre-flash, TTL direct meter- ing, manual flash

77.5(W) x 132 (H) x 95.5 (D) mm 370g (without batteries)

Frequency/ Repetition

1/12000

1

1.8

2

2.1

2.5

2.8

3.5

 

 

 

 

 

 

 

 

 

 

Alkaline

Lithium

 

Nickel hydride

Frequency (sec)

0.2 - 11

0.2 - 13

 

 

0.2 - 8

 

 

 

 

 

Repetition (times)

90 - 3200

250 - 8000

 

80 - 2800

 

 

 

 

 

 

 

 

 

Repetition is the approximate number of times that are achieved before a new battery is completely flat.

Specifications are based on the latest information available at the time of printing and are subject to change without notice.

PERFORMANCE

76

77

Image 39
Contents Applications Appendix Program Flash Maxxum FlashFor Proper and Safe USE Contents Cameras and Flash Units CamerasFlash Units Names of Parts Flash Unit Diagram Control PanelData Panel Names of PartsInstalling Batteries Chamber Close the battery-chamber doorChecking Batteries Attaching and Removal Auto Power ON/OFF and FilmThat the subject is within Flash range Mode Flash the BasicsPress the shutter-release but Ton partway down and checkSet the shutter speed, and focus the subject Mode Flash the BasicsExposure Modes Set the aperture and focus the subjectSet the aperture and shutter speed, and focus the sub- ject Exposure ModesZoom Flash Coverage Auto ZoomZoom Pull out the adapter Zoom Flash CoverageManual Zoom Built-In Wide Angle Adapter 17mm zoom angleHold The setting prevents mis-operation TEST-FLASH/MODELING FlashFlash once at the set light level Level 1/1~1/32 Bounce Flash FlashFlash may be set to the following angles Bounce Flash Adjusting Bounce AngleIlluminates the data panel at low-light levels Data Panel IlluminatorAF Illuminator Press the data panel illuminatorMODE/SELECT Button Mode and Select ButtonsManual Flash M Press the + or button to select the power level to be setHSS HIGH-SPEED Sync HSSPlay PanelUsing two flash units p WIRELESS/REMOTE Flash ModeTypes Of Wireless/Remote Flash Using the built-in flash pFollowing two modes are avail- able WIRELESS/REMOTE Flash ModeUsing the Wireless Remote Flash Controller p Wireless Flash RangeWIRELESS/REMOTE Flash Mode Check that the built-in flash 5600HS D are fully charged Using The Built-In FlashSet the camera to wireless flash Setting Wireless/Remote Flash By Flash OnlySwitch the 5600HS D on Using Two Flash UnitsSetting Up The Controller Setting Up The Off-Camera FlashTaking Photos Check that both flash units are fully chargedUse test flash to check the off-camera flash Press the select buttonRefer to the Wireless Remote Flash Controller manual Using Wireless Remote Flash ControllerRatio-Flash Control Using Two Or More Flash Units Using 5600HS D, 5400HS, 5400xi onlySet up the 5600HS D with the wireless ratio off-camera flash Press the select button Using with 3600HS D orAll the flash units in a and B group can be used Connecting Camera and Flash by CableEqualizing The Power Level Of All Flash Units Connecting by CableSetting Power Level Level Power LevelPower level for the flash can be adjusted Multiple Flash Multi Press the select button to blinkPress the + or button to Select the number of flashes Maximum Number Of Continuous Flashes Multiple Flash MultiPress the select button to blink Level on the data panel Press the select button Set the shutter speed and aperturePress the select button to Reset to Default SettingsCustom Function Press the select button for SecondsTime to auto power off when using wireless Press the mode buttonWireless channel setting Time to auto power offMaxxum/Dynax 9xi, 7xi, 5xi, 3xi, SPxi Using xi Series Single Lens Reflex CamerasUSE in Combination with Other Products Using Early AF Series Single Lens Reflex CamerasUsing APS Single Lens Reflex Cameras Using Minolta Digital CamerasAccessories AccessoriesBatteries TemperatureMaintenance During PhotographyPerformance PerformanceMemo 9222-8841-11 P-B00X