D14041.02 January 2008 | TANDBERG FieldView Device User Guide |
2.4. Turning Power On or Off
There are three power modes: On, Off and Standby
2.4.1. Power On Mode
Press and release the Power button to turn the FieldView Device on. When you first turn the camera on, you may be required to log in, and a touch panel calibration screen may appear.
When the power is on the Power indicator LED is green.
2.4.2. Power Off Mode
Turning off the FieldView Device automatically logs you out. To turn the
FieldView Device Off, press and hold the Power button for two seconds.
•If the FieldView Device was on, a message is displayed indicating that the FieldView Device is turning off. If a call was active a prompt appears, asking for confirmation to terminate the call.
•If the FieldView Device was in standby, it immediately switches off.
When the power is off the Power indicator LED is off.
2.4.3. Standby Mode
Standby mode provides longer battery life than Power On mode because it shuts down the display and puts the camera into a low power mode. However, incoming calls may still be received. To enter Standby mode, first turn the FieldView Device on, then press and release the Power button to enter Standby mode.
If a call was active a prompt is displayed asking for confirmation to terminate the call. A message is displayed indicating that the FieldView Device is entering Standby.
When the FieldView Device is in Standby mode, the Power indicator LED is green. This is the only visible indication that the FieldView Device is in Standby mode and is capable of receiving incoming calls.
To come out of Standby, press the Power button or answer an incoming call. If your site requires a
The FieldView Device also enters Standby mode automatically after a configurable amount of time. To set this:
1.From the standard Viewfinder display window, press and release the Display button three times (or until the Main Menu appears).
2.Tap the Configuration option with the stylus to display the Configuration screen.
3.Display the General tab and set the time in the Standby Timeout field. Enter a time of ‘0’ to disable automatic Standby mode.
2.4.4.Resetting the FieldView Device (Soft Reset)
If the FieldView Device becomes
Do not perform a soft reset on the FieldView Device unless it stops responding to normal operations.
CAUTION:
A hard reset can be generated using the reset switch accessible through the access hole located near the SD memory card slot.
The hard reset should not be used by
damage to the FieldView Device file system may result.
6