JVC TK-C625 manual Point-to-Point Communication System, Setting not Required

Page 11

Connections & Installation (continued)

11

EN

Point-to-Point Communication System

The following illustration shows a system in which a remote control unit (or a similar piece of equipment)

controls a single camera.

Video out

Control signal cable

AC 24 V power supply

(A CAUTIONS)

Switch 4 : OFF (Point to Point) Switch 8 : ON (Terminated 110 K)

Monitor

Controller

Observe the following points when connecting components together:

Turn all the components off before proceeding.

Read the instruction manuals of all components before proceeding.

8ACable ConnectionsB (A pg. 16) (Terminal side of the Ceiling Mount)

Control signal cable

To controller

Coaxial cable

To monitor

To the AC 24V power

supply. Listed class 2

Power cable input only.

(A CAUTIONS)

8ASwitch SettingsB (A pg. 13)

(Setting switches are on the side of the Ceiling Mount)

Setting not

 

required

ON

 

1 2 3 4 5 6 7 8

Switch 1 : Invalid (Set to OFF)

Switch 2 : Invalid (Set to OFF)

Switch 3 : Invalid (Set to OFF)

Switch 4 : OFF

Switch 5 : Configure in accordance with the requirements of the controller communication system.

Switch 7 : Invalid (Set to OFF)

Switch 8 : ON

MEMO

If this camera or the cables connected to this camera are used in places subject to strong electromagnetic waves or other forms of magnetism, such as those near a radio or TV transmitter, a power transformer or an electric motor, the picture may suffer from noise and colors may be affected.

An optionally available controller is required to use a TK-C625 camera. Please contact your local dealer or installer for more information about these controllers.

CAUTIONS

The AC 24 V power supply must be isolated from the primary line. (ISOLATED POWER ONLY)

In order to prevent an excessive current flow through the power supply wire or camera due to a short circuit, a fuse must be installed in the power supply line.

Image 11
Contents For Customer Use Dome Type Camera TK-C625INSTRUCTIONSInformation Safety PrecautionsRisk of Electric Shock Do not Open Important Safeguards Contents CharacteristicsInstall the unit on a strong and stable surface Operating PrecautionsZooming operation Preset positionsName and Function of Parts Auxiliary Switch Ceiling Mount Setting Switch Side Camera Machine ID Machine ID Setting Switch Setting SwitchMulti-Drop Communication System Connections & Installation110 K Video SWITCHER, etcCAM2 Length of stub CAM32 Length of stub ACable ConnectionsB a pg Terminal side of the Ceiling Mount Setting not RequiredSwitch 7 Invalid Set to OFF Switch 8 on Point-to-Point Communication SystemCamera Controller RX + TX + DuplexExample connection with an RM-P2580 SimplexSync Switch SettingsProtocol That the number LL is correct Machine ID Setting SwitchDisplayed as ID- LL. Check Machine ID Installation Lead the cable through the Cover Cable ConnectionsMake a hole in the ceiling Connect the cable to this camera Remove the CoverRating Connecting an RG-59 coaxial cableConductor Connect this to the remote control unit RM-P2580Connect to an AC 24 V Supply Connection LengthFasten the ceiling mount to the ceiling Installing the Ceiling MountAttach the Safety Wire Fit the camera to the ceiling mount Installing the Camera20 EN Check that the Locking Screw is loosenedPress the SET button Setup ProcedureSetting Up the Camera Using RM-P258021 Press and hold the Menu button for 3 seconds22 EN Menu Screen ConfigurationSetting Up the Camera Using RM-P2580 Private Mask Mode OFF Camera Function 2 Screen 24 ENCamera Function 1 Screen Auto Return AF for IRTilt Limit PAN Limit26 EN Camera TITLE/ALARM ScreenCamera ALC/VIDEO Screen Auto PAN/PATROL/TRACE Screen 28 ENPOS. Function SET Screen 30 EN Factory Settings ScreenPrivate Mask Setup Set the position for the left limit Manual PAN Limit SetupSelect a camera. ARM-P2580AINSTRUCTIONSB Menu screen display. a pg , steps 2 toRight Limit Invalid Range Settings that override the Manual Pan LimitBasic operation of Manual Pan Limit Operations that override the Manual Pan LimitSelect the camera. a RM-P2580AINSTRUCTIONSB Camera Title SetupRepeat Steps 5 to Area Display Setup TitlePress the FAR button Direction Standard Axis Screen Area Display Setup DirectionEast WestCamera buttonNNumeric keyCamera NumberNENTER button Alarm Title SetupRepeat steps 5 to 7 for each alarm title Alarm Title Edit Screen Title input FieldSelect camera. ARM-P2580AINSTRUCTIONSB Auto PAN SetupSet the Auto PAN Mode and Auto PAN Speed Set the end position only when in the Return modeSet the length of time a camera will stay in each position Auto Patrol SetupChange the Auto Patrol mode Set a patroll positionAuto Trace Setup Position buttonNNumeric key position numberNENTER button Position Title SetupSelect a preset position. a RM-P2580 Ainstructionsb Repeat steps 5 to 7 for each title characterOther Troubleshooting42 EN General SpecificationsExternal Dimensions Unit mm Ceiling Mount Hole Unit mm Pan/Tilt MechanismTK-C625 Dome Type Camera