Specifications

8Camera

Image pickup device:1/4 type, interline transfer CCD

 

TK-C625E: 752 (H) x 582 (V) pixels

 

TK-C625U: 768 (H) x 494 (V) pixels

Sync system

: Internal, Line Lock

Video output

: VBS 1V (p-p) 75 K

Scanning frequencies : TK-C625E: 15.625 (H), 50 Hz (V)

 

TK-C625U: 15.734 (H), 59.94 Hz (V)

S/N

: 50 dB (typical) (AGC mode: OFF, Enhance

 

level: -5)

Horizontal resolution : 540 lines and above (typical) (WIDE end,

 

 

Centre)

Minimum object illumination :

Color mode

:

3.6 lx (50 % output, AGC 20 dB, WIDE end)

 

 

1.8 lx (25 % output, AGC 20 dB, WIDE end)

B&W mode

: 0.15 lx (50 % output, AGC 20 dB, WIDE

 

 

end)

White balance

: TTL auto tracking/Manual

Electronic shutter :

 

TK-C625E

: 1/50 (standard), 1/120 (60 Hz flickerless),

 

 

1/250, 1/500, 1/1000, 1/2000, 1/4000,

 

 

1/10000

TK-C625U

: 1/60 (standard), 1/100 (50 Hz flickerless),

 

 

1/250, 1/500, 1/1000, 1/2000, 1/4000,

1/10000

Backlight compensation: Possible, 4 photometry areas selectable

Color level adjustment: Possible

Contour correction: Both horizontal and vertical (level adjustable)

8 Lens

 

Zoom ratio

: Approx. x12

Focal distance

: 3.8 mm to 45.6 mm

Maximum aperture : F1.6 (WIDE) to F2.7 (TELE)

8Pan/Tilt Mechanism

Panning range

: 360° endless revolution

 

Panning speed

: 1.5°/s to 180°/s

 

Tilting range

: 0° to 90° (Horizontal - Straight

 

 

downwards - Horizontal)

 

Tilting speed

: 1°/s to 120°/s

 

8 General

 

 

Power supply

: TK-C625E: AC 24 V, 50 Hz, 1.5 A

 

 

TK-C625U: AC 24 V, 60 Hz, 20 W

 

No. of preset positions : 100

 

Applicable control unit

: RM-P2580

 

Ambient temperature : -10Ito 50I (operating),

 

 

0I to 40I (recommended)

 

Ambient humidity

: 35 % to 90 % RH

 

 

(without condensation)

 

Mass

: 1.3 kg

 

Accessories:

 

 

TK-C625E

: Instructions

1

 

Ceiling Mount

1

 

Template

1

 

Wire Clamp

1

TK-C625U

: Instructions

1

 

Warranty Card

1

 

Service Information Card

1

 

Ceiling Mount

1

 

Template

1

 

Ferrite Core

1

 

Wire Clamp

1

8 External Dimensions [Unit: mm]

8 Ceiling Mount Hole [Unit: mm]

36

Screw

Positions

 

Mounting

127

hole

 

190

 

 

83.5

SR55

120

83.5

1 7

46

Screw Positions

46

70

Specifications and appearance of this unit and related products are

subject to change for product improvement without prior notice.

Image 43
Contents For Customer Use Dome Type Camera TK-C625INSTRUCTIONSRisk of Electric Shock Do not Open Safety PrecautionsInformation Important Safeguards Contents CharacteristicsInstall the unit on a strong and stable surface Operating PrecautionsZooming operation Preset positionsName and Function of Parts Auxiliary Switch Ceiling Mount Setting Switch Side CameraMachine ID Machine ID Setting Switch Setting SwitchMulti-Drop Communication System Connections & InstallationCAM2 Length of stub CAM32 Length of stub Video SWITCHER, etc110 K ACable ConnectionsB a pg Terminal side of the Ceiling Mount Setting not RequiredSwitch 7 Invalid Set to OFF Switch 8 on Point-to-Point Communication SystemCamera Controller RX + TX + DuplexExample connection with an RM-P2580 SimplexProtocol Switch SettingsSync Displayed as ID- LL. Check Machine ID Setting SwitchThat the number LL is correct Machine ID Installation Lead the cable through the Cover Cable ConnectionsMake a hole in the ceiling Connect the cable to this camera Remove the CoverRating Connecting an RG-59 coaxial cableConductor Connect this to the remote control unit RM-P2580Connect to an AC 24 V Supply Connection LengthAttach the Safety Wire Installing the Ceiling MountFasten the ceiling mount to the ceiling Fit the camera to the ceiling mount Installing the Camera20 EN Check that the Locking Screw is loosenedPress the SET button Setup ProcedureSetting Up the Camera Using RM-P258021 Press and hold the Menu button for 3 secondsSetting Up the Camera Using RM-P2580 Menu Screen Configuration22 EN Private Mask Mode OFF Camera Function 1 Screen 24 ENCamera Function 2 Screen Auto Return AF for IRTilt Limit PAN Limit26 EN Camera TITLE/ALARM ScreenCamera ALC/VIDEO Screen Auto PAN/PATROL/TRACE Screen 28 ENPOS. Function SET Screen 30 EN Factory Settings ScreenPrivate Mask Setup Set the position for the left limit Manual PAN Limit SetupSelect a camera. ARM-P2580AINSTRUCTIONSB Menu screen display. a pg , steps 2 toRight Limit Invalid Range Settings that override the Manual Pan LimitBasic operation of Manual Pan Limit Operations that override the Manual Pan LimitSelect the camera. a RM-P2580AINSTRUCTIONSB Camera Title SetupPress the FAR button Area Display Setup TitleRepeat Steps 5 to Direction Standard Axis Screen Area Display Setup DirectionEast WestCamera buttonNNumeric keyCamera NumberNENTER button Alarm Title SetupRepeat steps 5 to 7 for each alarm title Alarm Title Edit Screen Title input FieldSelect camera. ARM-P2580AINSTRUCTIONSB Auto PAN SetupSet the Auto PAN Mode and Auto PAN Speed Set the end position only when in the Return modeSet the length of time a camera will stay in each position Auto Patrol SetupChange the Auto Patrol mode Set a patroll position Auto Trace Setup Position buttonNNumeric key position numberNENTER button Position Title SetupSelect a preset position. a RM-P2580 Ainstructionsb Repeat steps 5 to 7 for each title character42 EN TroubleshootingOther General SpecificationsExternal Dimensions Unit mm Ceiling Mount Hole Unit mm Pan/Tilt MechanismTK-C625 Dome Type Camera