JVC TK-C625 manual Auto Patrol Setup, Set a patroll position, Change the Auto Patrol mode

Page 39

Setting Up the Camera Using RM-P2580 (continued)39

EN

AUTO PATROL Setup

 

High

 

 

speed

 

POSITION

 

POSITION

 

2

1

 

 

 

High speed

 

High speed

POSITION

speed

 

 

High

POSITION

4

 

 

3

 

 

MENU button

POSITION button

SET button

PAN lever

 

CAMERA button

 

 

 

 

 

 

 

REMOTE CONTROL UNIT RM-P2580

SETUP

CAMERA

 

 

POSITION

 

 

 

 

POWER

 

 

 

 

 

 

 

MENU

SET

ALARM

 

 

 

AUTO

F-1

F-2

F-3

 

 

 

 

 

 

KEY LOCK

 

 

 

 

 

 

 

 

LENS

 

CAMERA/POSITION

 

 

PAN/TILT

 

 

SPEED

1

2

3

CAMERA

POSI-

 

 

 

 

 

 

 

 

 

TION

 

 

 

CLOSE IRIS OPEN

4

5

6

OPTION

OPTION

 

 

 

 

1

2

NEAR

FOCUS

7

8

9

AUTO

AUTO

 

FAR

 

 

AF

PAN

PATROL

 

WIDE

ZOOM TELE

CLEAR

0

ENTER

 

 

 

 

 

 

/HOME

 

 

 

 

 

TELE

FAR

 

ENTER

AUTO

 

button

button

button

PATROL

 

WIDE button

 

 

 

button

 

 

 

 

 

NEAR button

 

 

 

 

 

 

AUTO PAN / PATROL / TRACE

AUTO PAN SET..

AUTO PATROL SET..

AUTO TRACE SET..

AUTO PAN / TRACE VIDEO ..

RM . A . PAN KEY

A . PAN

RM . A . PATROL KEY

A . PATROL

<MENU> RETURN <SET> SUB MENU

AUTO PAN/PATROL/TRACE Screen

Use the AUTO PATROL screen to set the configuration of the Auto Patrol function, which moves the camera between several positions at a high speed. Patrol positions 1-100 can be set in each of three modes (MODES 1 to 3). It is recommended that these three modes be set according to the day of the week or the time of day. For example: MODE 1 for nighttime and MODE 2 for daytime.

1 Select the camera. (A RM-P2580AINSTRUCTIONSB)

CAMERA buttonNNumeric key (Camera Number)NENTER button

The picture of the selected camera is output.

2 Display the MENU screen. (A pg. 21, steps 2 to 4)

MENU button (3 sec.) N Select ACAMERA..B using the PAN lever NSET button.

The AMENUB screen will be displayed.

3 Tilt the PAN lever up or down to move the cursor (E) to AAUTO PAN/PATROL/TRACE..B and press the SET button.

The AAUTO PAN/PATROL/TRACE..B screen is displayed.

4 Move the cursor (E) to AAUTO PATROL SET..B and press the

SET button.

The AAUTO PATROL SET MODE 1B screen is displayed.

5 Tilt the PAN lever to move the cursor (E) to the PATROL position to be set.

To display the next page (PATROL positions 9 to 19), press the TELE button.

To display the previous page, press the WIDE button.

6 Set a patroll position.

POSITION buttonNNumeric key (position number) N ENTER button

Positions from PATROL 1 to 100 are set in the order of HOME, followed by POS 1 to POS 99.

7 Set the length of time a camera will stay in each position.

Use the PAN lever to the left or right to set the time period.

Available set values: SKIP, 10s, 20s, 30s, 45s, 1min, 2min. (Selecting ASKIPB skips that position and moves to the next position.)

The factory setting is 10s for all positions.

8 Repeat steps 5 to 7 for each patrol position.

Set the patrol positions and time periods of all patrol numbers in the same way.

AUTO PATROL SET MODE 1

PATROL 1

HOME

10s

PATROL 2

POS 1

10s

PATROL 3

POS 2

10s

PATROL 4

POS 3

10s

PATROL 5

POS 4

10s

PATROL 6

POS 5

10s

PATROL 7

POS 6

10s

PATROL 8

POS 7

10s

<FOCUS> MODE <ZOOM> PAGE <MENU> RETURN

AUTO PATROL SET MODE 1 Screen (Example showing PATROL Nos.1 to 8)

AUTO PATROL SET MODE 1

PATROL 9

POS 8

10s

PATROL 10

POS 9

10s

PATROL 11

POS 10

10s

PATROL 12

POS 11

10s

PATROL 13

POS 12

10s

PATROL 14

POS 13

10s

PATROL 15

POS 14

10s

PATROL 16

POS 15

10s

<FOCUS> MODE <ZOOM> PAGE <MENU> RETURN

9 Change the Auto Patrol mode.

Press the FAR button or NEAR button to change the mode.

After changing to a new mode, repeat steps 5 to 8.

10Press the MENU button.

The screen returns to the previous menu.

After the above setup, Auto Patrol of the camera can be started by pressing the AUTO PATROL button on the RM-P2580.

To change the Auto Patrol mode after the above setup, display the AUTO PATROL SET MODE screen and press the FAR button or NEAR button.

The Auto Patrol function can only be set from an RM-P2580. Note that it differs to auto sequence operations available with other remote control units.

AUTO PATROL SET MODE 1 Screen (Example showing PATROL Nos. 9 to 16)

Image 39
Contents For Customer Use Dome Type Camera TK-C625INSTRUCTIONSSafety Precautions Risk of Electric Shock Do not OpenInformation Important Safeguards Contents CharacteristicsInstall the unit on a strong and stable surface Operating PrecautionsZooming operation Preset positionsName and Function of Parts Auxiliary Switch Ceiling Mount Setting Switch Side CameraMachine ID Machine ID Setting Switch Setting SwitchMulti-Drop Communication System Connections & InstallationVideo SWITCHER, etc CAM2 Length of stub CAM32 Length of stub110 K ACable ConnectionsB a pg Terminal side of the Ceiling Mount Setting not RequiredSwitch 7 Invalid Set to OFF Switch 8 on Point-to-Point Communication SystemCamera Controller RX + TX + DuplexExample connection with an RM-P2580 SimplexSwitch Settings ProtocolSync Machine ID Setting Switch Displayed as ID- LL. CheckThat the number LL is correct Machine ID Installation Lead the cable through the Cover Cable ConnectionsMake a hole in the ceiling Connect the cable to this camera Remove the CoverRating Connecting an RG-59 coaxial cableConductor Connect this to the remote control unit RM-P2580Connect to an AC 24 V Supply Connection LengthInstalling the Ceiling Mount Attach the Safety WireFasten the ceiling mount to the ceiling Fit the camera to the ceiling mount Installing the Camera20 EN Check that the Locking Screw is loosenedPress the SET button Setup ProcedureSetting Up the Camera Using RM-P258021 Press and hold the Menu button for 3 secondsMenu Screen Configuration Setting Up the Camera Using RM-P258022 EN Private Mask Mode OFF 24 EN Camera Function 1 ScreenCamera Function 2 Screen Auto Return AF for IRTilt Limit PAN Limit26 EN Camera TITLE/ALARM ScreenCamera ALC/VIDEO Screen Auto PAN/PATROL/TRACE Screen 28 ENPOS. Function SET Screen 30 EN Factory Settings ScreenPrivate Mask Setup Set the position for the left limit Manual PAN Limit SetupSelect a camera. ARM-P2580AINSTRUCTIONSB Menu screen display. a pg , steps 2 toRight Limit Invalid Range Settings that override the Manual Pan LimitBasic operation of Manual Pan Limit Operations that override the Manual Pan LimitSelect the camera. a RM-P2580AINSTRUCTIONSB Camera Title SetupArea Display Setup Title Press the FAR buttonRepeat Steps 5 to Direction Standard Axis Screen Area Display Setup Direction East WestCamera buttonNNumeric keyCamera NumberNENTER button Alarm Title SetupRepeat steps 5 to 7 for each alarm title Alarm Title Edit Screen Title input FieldSelect camera. ARM-P2580AINSTRUCTIONSB Auto PAN SetupSet the Auto PAN Mode and Auto PAN Speed Set the end position only when in the Return modeSet the length of time a camera will stay in each position Auto Patrol SetupChange the Auto Patrol mode Set a patroll positionAuto Trace Setup Position buttonNNumeric key position numberNENTER button Position Title SetupSelect a preset position. a RM-P2580 Ainstructionsb Repeat steps 5 to 7 for each title characterTroubleshooting 42 ENOther General SpecificationsExternal Dimensions Unit mm Ceiling Mount Hole Unit mm Pan/Tilt MechanismTK-C625 Dome Type Camera