ALARM TITLE Setup

MENU button

 

 

 

 

 

 

 

 

SET button

 

 

 

 

PAN lever

 

 

 

 

 

 

 

 

 

CAMERA button

 

 

 

 

 

 

 

 

 

 

REMOTE CONTROL UNIT RM-P2580

SETUP

CAMERA

 

 

POSITION

 

 

 

 

POWER

 

 

 

 

 

 

 

MENU

SET

ALARM

 

 

 

AUTO

F-1

F-2

F-3

 

 

KEY LOCK

 

 

 

 

 

 

 

 

LENS

 

CAMERA/POSITION

 

 

PAN/TILT

 

 

SPEED

1

2

3

CAMERA

POSI-

 

 

 

 

 

 

 

 

 

TION

 

 

 

CLOSE

IRIS

OPEN

4

5

6

OPTION

OPTION

 

 

 

 

 

 

1

2

NEAR

FOCUS

FAR

7

8

9

AUTO

AUTO

AF

 

 

PAN

PATROL

WIDE

ZOOM

TELE

CLEAR

0

ENTER

 

 

 

 

 

 

/HOME

 

 

 

FAR

Numeric

ENTER

button

keys

button

Use the ALARM TITLE screen to set the alarm titles to be displayed when an alarm signal is transmitted. Up to 10 alarm titles (ALARM TITLE 1 to 10) can be set and each title can be up to 12 characters in length.

1 Select the camera. (A RM-P2580AINSTRUCTIONSB)

CAMERA buttonNNumeric key(Camera Number)NENTER button

The picture of the selected camera is output.

2 Display the MENU screen. (A pg. 21, steps 2 to 4)

MENU button (3 sec.) N Select ACAMERA..B using the PAN lever N SET button.

The AMENUB screen will be displayed.

3 Tilt the PAN lever up or down to move the cursor (E) to ACAM. TITLE/ALARM..B and press the SET button.

The ACAMERA TITLE/ALARMB screen is displayed.

4 Move the cursor (E) to the AALARM TITLE EDIT..B item and press the SET button.

WIDE button

NEAR button

MENU

CAM.FUNCTION1..

CAM.FUNCTION2..

CAM.TITLE/ALARM..

CAM.ALC/VIDEO..

AUTO PAN/PATROL/TRACE..

POS.FUNCTION SET..

FACTORY SETTINGS..

<MENU> EXIT <SET> SUB MENU

MENU Screen

CAMERA TITLE / ALARM

CAM.TITLE EDIT..

 

AREA DISPLAY

OFF

ALARM TITLE SIZE

DOUBLE

ALARM TITLE EDIT..

 

ALARM INPUT..

 

ALARM OUTPUT..

 

<MENU> RETURN <SET> SUB MENU

CAMERA TITLE/ALARM Screen

Space

Blinking

 

 

 

Character area

 

ALARM TITLE EDIT

 

No.∗ ∗

 

 

0123456789ABCDEFGHIJKLMNO

 

PQRSTUVWXYZabcdefghijklmno

A MENO

p q r s t u v w x y z ÄÖÜÊÎÔÛÇÑäëïöü

 

âêîôûáéíóúàèìòùçñß¡¿ . , ’ - : /

 

() <>

 

 

 

 

 

CLR CANCEL [

]

[

]

INS DEL

 

 

W

 

T

 

 

 

<FOCUS KEY> ALARM No . SELECT

 

<MENU> RETURN <SET> CHAR .SET

 

 

[

 

 

 

]

 

ALARM TITLE EDIT Screen

Title input

 

 

field

The AALARM TITLE EDIT No.1B screen will be displayed.

The first character appears blinking and input is enabled.

5 Use the PAN lever to select the first character of the title from the character area.

The selected character will appear blinking.

The selected character is displayed in the title input field.

6 Press the SET button.

The first character of the title is now confirmed, and input of the second character is possible.

If the WIDE button is pressed, the title input field moves to the left. Use this to correct previously input characters.

7 Press the FAR button.

The next AALARM TITLE EDIT No.2B screen is displayed.

If the NEAR button is pressed, the previous AALARM TITLE EDIT No.1B screen is displayed.

8 Repeat steps 5 to 7 for each alarm title.

Complete the input of all the alarm titles (AALARM TITLE EDITB 1 to 10) in the same way.

9 Press the MENU button.

The screen returns to the previous menu.

MEMO

Only displayed for the TK-C625E model.

RM-P2580 units need to be configured to display alarm titles. Use the RM-P2580 menu settings to do this:

APress and hold the MENU button for 3 seconds to display the SETUP screen on the remote control unit.

BFirst select the ACONTROL UNIT..B screen, then the ADATA I/OB screen and finally the AINPUT ASSIGNMENTB screen.

CSelect AALARM TEXTB then AEDIT 1B, the alarm title set as AALARM TITLE EDIT 1B is displayed on the monitor.

*The alarm signals are input into the DATA I/O terminals on the rear panel of the RM-P2580.

Image 37
Contents For Customer Use Dome Type Camera TK-C625INSTRUCTIONSRisk of Electric Shock Do not Open Safety PrecautionsInformation Important Safeguards Contents CharacteristicsInstall the unit on a strong and stable surface Operating PrecautionsZooming operation Preset positionsName and Function of Parts Machine ID Machine ID Setting Switch Ceiling Mount Setting Switch Side CameraSetting Switch Auxiliary SwitchMulti-Drop Communication System Connections & InstallationCAM2 Length of stub CAM32 Length of stub Video SWITCHER, etc110 K Switch 7 Invalid Set to OFF Switch 8 on Setting not RequiredPoint-to-Point Communication System ACable ConnectionsB a pg Terminal side of the Ceiling MountExample connection with an RM-P2580 DuplexSimplex Camera Controller RX + TX +Protocol Switch SettingsSync Displayed as ID- LL. Check Machine ID Setting SwitchThat the number LL is correct Machine ID Installation Make a hole in the ceiling Connect the cable to this camera Cable ConnectionsRemove the Cover Lead the cable through the CoverRating Connecting an RG-59 coaxial cableConnect to an AC 24 V Supply Connect this to the remote control unit RM-P2580Connection Length ConductorAttach the Safety Wire Installing the Ceiling MountFasten the ceiling mount to the ceiling 20 EN Installing the CameraCheck that the Locking Screw is loosened Fit the camera to the ceiling mountSetting Up the Camera Using RM-P258021 Setup ProcedurePress and hold the Menu button for 3 seconds Press the SET buttonSetting Up the Camera Using RM-P2580 Menu Screen Configuration22 EN Private Mask Mode OFF Camera Function 1 Screen 24 ENCamera Function 2 Screen Tilt Limit AF for IRPAN Limit Auto Return26 EN Camera TITLE/ALARM ScreenCamera ALC/VIDEO Screen Auto PAN/PATROL/TRACE Screen 28 ENPOS. Function SET Screen 30 EN Factory Settings ScreenPrivate Mask Setup Select a camera. ARM-P2580AINSTRUCTIONSB Manual PAN Limit SetupMenu screen display. a pg , steps 2 to Set the position for the left limitBasic operation of Manual Pan Limit Settings that override the Manual Pan LimitOperations that override the Manual Pan Limit Right Limit Invalid RangeSelect the camera. a RM-P2580AINSTRUCTIONSB Camera Title SetupPress the FAR button Area Display Setup TitleRepeat Steps 5 to East Area Display Setup DirectionWest Direction Standard Axis ScreenRepeat steps 5 to 7 for each alarm title Alarm Title SetupAlarm Title Edit Screen Title input Field Camera buttonNNumeric keyCamera NumberNENTER buttonSet the Auto PAN Mode and Auto PAN Speed Auto PAN SetupSet the end position only when in the Return mode Select camera. ARM-P2580AINSTRUCTIONSBChange the Auto Patrol mode Auto Patrol SetupSet a patroll position Set the length of time a camera will stay in each positionAuto Trace Setup Select a preset position. a RM-P2580 Ainstructionsb Position Title SetupRepeat steps 5 to 7 for each title character Position buttonNNumeric key position numberNENTER button42 EN TroubleshootingOther External Dimensions Unit mm Ceiling Mount Hole Unit mm SpecificationsPan/Tilt Mechanism GeneralTK-C625 Dome Type Camera

TK-C625 specifications

The JVC TK-C625 is a compact yet highly effective industrial camera that has made a significant impact in various surveillance and monitoring contexts. Developed by JVC, a pioneer in video technology, the TK-C625 stands out for its impressive features, innovative technologies, and reliable performance.

At the heart of the TK-C625 is a high-resolution CCD sensor, which captures images with exceptional clarity and detail. With a resolution of 600 TV lines, this camera is adept at delivering sharp images even in challenging lighting conditions. This capability makes it suitable for a variety of environments, including retail spaces, educational institutions, and parking lots, where detail and accuracy are paramount.

One of the notable features of the TK-C625 is its effective low-light performance. Equipped with a built-in Automatic Gain Control (AGC) feature, the camera can enhance sensitivity in low-light environments, ensuring that quality footage can be captured even in dimly lit areas. This feature is crucial for security applications where monitoring takes place during nighttime hours.

In addition to its impressive imaging capabilities, the TK-C625 offers versatile mounting options. The compact design allows for a range of installation configurations, including wall, ceiling, or even desktop setups. The camera's lightweight build is also a plus, facilitating ease of installation without compromising on stability.

The JVC TK-C625 incorporates advanced signal processing technologies, providing enhanced image quality and reducing noise, which is particularly important in surveillance situations where clarity can mean the difference between identifying a suspect or missing critical details. Its electronic shutter technology allows for quick response to changing light conditions, improving its adaptability to various scenes and preventing overexposure.

Another significant aspect of the TK-C625 is its robust construction. Designed with durability in mind, the camera can withstand the rigors of consistent use in commercial settings, delivering reliable operation over long periods. This resilience is further complemented by its ease of use and maintenance, making it an ideal choice for businesses seeking dependable surveillance solutions.

Overall, the JVC TK-C625 is a high-performance camera that combines advanced features with user-friendly operation. Its high resolution, low-light capabilities, flexible installation, and durable design make it a standout option for surveillance professionals looking for quality and reliability in their monitoring solutions.