JVC TK-C625 manual Auto Trace Setup

Page 40

40 Setting Up the Camera Using RM-P2580 (continued)

EN

AUTO TRACE Setup

MENU button

 

 

AUTO PAN button

 

SET button

 

 

 

 

PAN lever

 

 

 

 

 

 

 

 

 

CAMERA button

 

 

 

 

 

 

 

 

 

 

 

REMOTE CONTROL UNIT RM-P2580

SETUP

CAMERA

 

POSITION

 

 

 

 

 

POWER

 

 

 

 

 

 

 

MENU

SET

ALARM

 

 

 

AUTO

F-1

F-2

F-3

 

 

KEY LOCK

 

 

 

 

 

 

 

 

LENS

 

CAMERA/POSITION

 

 

PAN/TILT

 

 

SPEED

1

2

3

CAMERA

POSI-

 

 

 

 

 

 

 

 

 

TION

 

 

 

CLOSE

IRIS

OPEN

4

5

6

OPTION

OPTION

 

 

 

 

 

 

1

2

NEAR

FOCUS

FAR

7

8

9

AUTO

AUTO

AF

 

 

PAN

PATROL

WIDE

ZOOM

TELE

CLEAR

0

ENTER

 

 

 

 

 

 

/HOME

 

 

 

Numeric ENTER AUTO

keys button PATROL

Use the AUTO TRACE screen to set the Auto Trace function, which stores and reproduces the actions of a manual camera operation (up to 30 seconds).

1 Select the camera. (A RM-P2580AINSTRUCTIONSB)

CAMERA buttonNNumeric key (Camera Number) NENTER button

The picture of the selected camera is output.

2 Display the MENU screen. (A pg. 21, steps 2 to 4)

MENU button (3 sec.) N Select ACAMERA..B using the PAN lever NSET

button.

The AMENUB screen will be displayed.

3 Tilt the PAN lever up or down to move the cursor (E) to

AAUTO PAN/PATROL/TRACE..B and press the SET button.

The AAUTO PAN/PATROL/TRACEB screen is displayed.

4 Move the cursor (E) to AAUTO TRACE SET..B and press the

SET button.

ZOOM button

FOCUS button

button

The AAUTO TRACE SETB screen is displayed.

5 Set the patrol start position.

Using the PAN lever and the ZOOM button and FOCUS button, set the

MENU

CAM.FUNCTION1..

CAM.FUNCTION2..

CAM.TITLE/ALARM..

CAM.ALC/VIDEO..

AUTO PAN/PATROL/TRACE.. POS.FUNCTION SET.. FACTORY SETTINGS..

<MENU> EXIT <SET> SUB MENU

MENU Screen

camera position at which the Auto Trace function is to be started.

6 Press the SET button (to start memorization of manual

camera operations).

Auto Trace starts. Operate the camera using the PAN lever, and the

ZOOM button and FOCUS button.

The Auto Trace function can memorize camera operations for up to 30

seconds, during this period ALEARNING REMAINDER T: **sB is

displayed in the screen.

AUTO PAN / PATROL / TRACE

AUTO PAN SET..

AUTO PATROL SET..

AUTO TRACE SET..

AUTO PAN / TRACE VIDEO ..

RM . A . PAN KEY

A . PAN

RM . A . PATROL KEY

A . PATROL

<MENU> RETURN <SET> SUB MENU

AUTO PAN/PATROL/TRACE Screen

AUTO TRACE SET

SET START POSITION

<MENU> RETURN <SET> LEARN

AUTO TRACE SET Screen

AUTO TRACE SET

SET START POSITION

LEARNING REMAINDER T : ∗ ∗ s <MENU> RETURN <SET> END

Storage finishes automatically after 30 seconds.

Perform step 7 only when finishing the storage but before 30 seconds elapses.

Recording time may shorten depending on details of the operation. (Shortest recording duration is approximately 10 seconds)

7 Press the SET button to end the memorization of manual camera operations.

This ends recording of Auto Trace and a message indicating ADATA SAVEDB will be displayed.

8 Press the MENU button.

The screen returns to the AAUTO PAN/PATROL/TRACEB menu.

MEMO

Saving of auto operations will not be possible when this menu is displayed.

Manual Pan Limit remains valid when this menu is displayed.

Manual Pan Limit can be set upon exiting this menu without affecting the Auto Trace operation.

Auto Trace allows easy recording of manual operations, but positions may not be accurately reproduced during playback.

To Start Auto Trace Function

To let the camera execute reproduction of the Auto Trace operation, it is required to set the Auto Trace function in the AUTO PAN button or AUTO PATROL button of the RM-P2580.

A ARM. A. PAN KEYB (A pg. 29) and ARM. A. PATROL KEYB (A pg. 29). When the button to which the Auto Trace function is set is pressed, the lamp in the button lights up and Auto Trace reproduction starts.

The Auto Trace reproduction will repeat continually with a pause of 30 seconds between each operation.

To end the Auto Trace reproduction, press the button to which the Auto Trace function is set again so that the lamp in the button turns off.

AUTO TRACE SET Screen

Image 40
Contents Dome Type Camera TK-C625INSTRUCTIONS For Customer UseRisk of Electric Shock Do not Open Safety PrecautionsInformation Important Safeguards Characteristics ContentsOperating Precautions Install the unit on a strong and stable surfacePreset positions Zooming operationName and Function of Parts Ceiling Mount Setting Switch Side Camera Machine ID Machine ID Setting SwitchSetting Switch Auxiliary SwitchConnections & Installation Multi-Drop Communication SystemCAM2 Length of stub CAM32 Length of stub Video SWITCHER, etc110 K Setting not Required Switch 7 Invalid Set to OFF Switch 8 onPoint-to-Point Communication System ACable ConnectionsB a pg Terminal side of the Ceiling MountDuplex Example connection with an RM-P2580Simplex Camera Controller RX + TX +Protocol Switch SettingsSync Displayed as ID- LL. Check Machine ID Setting SwitchThat the number LL is correct Machine ID Installation Cable Connections Make a hole in the ceiling Connect the cable to this cameraRemove the Cover Lead the cable through the CoverConnecting an RG-59 coaxial cable RatingConnect this to the remote control unit RM-P2580 Connect to an AC 24 V SupplyConnection Length ConductorAttach the Safety Wire Installing the Ceiling MountFasten the ceiling mount to the ceiling Installing the Camera 20 ENCheck that the Locking Screw is loosened Fit the camera to the ceiling mountSetup Procedure Setting Up the Camera Using RM-P258021Press and hold the Menu button for 3 seconds Press the SET buttonSetting Up the Camera Using RM-P2580 Menu Screen Configuration22 EN Private Mask Mode OFF Camera Function 1 Screen 24 ENCamera Function 2 Screen AF for IR Tilt LimitPAN Limit Auto ReturnCamera TITLE/ALARM Screen 26 ENCamera ALC/VIDEO Screen 28 EN Auto PAN/PATROL/TRACE ScreenPOS. Function SET Screen Factory Settings Screen 30 ENPrivate Mask Setup Manual PAN Limit Setup Select a camera. ARM-P2580AINSTRUCTIONSBMenu screen display. a pg , steps 2 to Set the position for the left limitSettings that override the Manual Pan Limit Basic operation of Manual Pan LimitOperations that override the Manual Pan Limit Right Limit Invalid RangeCamera Title Setup Select the camera. a RM-P2580AINSTRUCTIONSBPress the FAR button Area Display Setup TitleRepeat Steps 5 to Area Display Setup Direction EastWest Direction Standard Axis Screen Alarm Title Setup Repeat steps 5 to 7 for each alarm title Alarm Title Edit Screen Title input Field Camera buttonNNumeric keyCamera NumberNENTER buttonAuto PAN Setup Set the Auto PAN Mode and Auto PAN SpeedSet the end position only when in the Return mode Select camera. ARM-P2580AINSTRUCTIONSBAuto Patrol Setup Change the Auto Patrol modeSet a patroll position Set the length of time a camera will stay in each positionAuto Trace Setup Position Title Setup Select a preset position. a RM-P2580 AinstructionsbRepeat steps 5 to 7 for each title character Position buttonNNumeric key position numberNENTER button42 EN TroubleshootingOther Specifications External Dimensions Unit mm Ceiling Mount Hole Unit mmPan/Tilt Mechanism GeneralTK-C625 Dome Type Camera