Attaching a Ceiling Flush Mount Bracket (Optional WB-S575)

The ceiling flush mount bracket (optional WB-S575) allows the camera to be installed flush with the ceiling surface. In this case the ceiling material should have a thickness of between 5 mm and 31 mm.

Mount hole

3 positions

Anchor bolt mount holes

Clamping screw

Loosen

Clamping bracket

Clamping screw

Clamping screw

Mount screws (x 4)

1.

2.

Make a hole (diameter 200 mm) in the ceiling.

Prepare the Ceiling Flush Mount Bracket.

Fully loosen the clamping screws (by turning them counterclock- wise).

Move the clamping brackets toward the inside as shown in the diagram.

Remove the four mount screws.

(1)

3. Clamp the Ceiling Flush Mount Bracket.

 

(1)

Fit the Ceiling Flush Mount Bracket into the hole in the ceiling.

Clamping screw

 

 

(2)

(2)

Ensure that the stoppers are pressing against the back of the

 

ceiling plate.

Stoppers

Anchor bolt mount

(3) Push the Ceiling Flush Mount Bracket all the way up and tight- en the three clamping screws (by turning them clockwise).

(3)

CAUTION

Make sure that the clamping brackets grip the ceiling plate firmly.

• If the ceiling flush mount bracket rattles after the clamping screws are tightened, loosen them fully and tighten them again.

If anchor bolts can be used, attach them using M8 - M10 (or 3/8 inch) nuts.

38

Image 38 Contents
TK-C676 Important Safeguards Contents Safety Precautions FeaturesProvided Accessories Instructions Ceiling mountCamera setups with which auto focusing may be difficult Precautions for Correct Operation Preset positions  ZoomingControls, Connectors and Indicators  Ceiling MountSetting Switches Camera Connector Female$ Machine ID Switch Connector MaleMulti-Drop Communication System Switch settings PObserve the following points when connecting compo Cable connections PMemo Terminal side of the Ceiling Mount Switch 7 OFF Switch 8 onPoint-to-Point Communication System Duplex Four wires must be connectedTwo wires must be connected For example connection with an RM-P2580 CameraSwitch Settings  Setting switchesBers on the RM-P2580 Camera ID check procedureMachine ID ExampleConnect the cables Cable ConnectionsMake a 90 mm diameter hole in the ceiling Remove the cover from the Ceiling MountAttach the cover Attaching the Ceiling Mount Attaching a safety wireAttach the drop prevention wire Attaching the CameraRotate the camera Ensure that the lock screw is looseFit the camera Tighten the lock screwPress and hold the Menu button for 3 seconds Setup ProcedureSetting the camera menus from an RM-P2580 Press the SET buttonMenu Screen Flow Menu for setting up the home posi- tion onlyMenu for setting up the function of each preset position Normal screenCamera Function Screen Camera TITLE/ALARM Screen Alarm Output Alarm Input PolarityAlarm Alarm OUT1Camera Video Adjustment Screen Camera ALC/ExDR screen10 dB AGC ModeExDR Mode Sense UPLevel ColourMode LOWArea Edit Alarm DisplayHome Motion Detect Screen DemonstrationAuto PAN/PATROL/TRACE Screen Factory Settings screen Position Function SET ScreenPrivate Mask Setup Repeat steps 5 and 6 for each title character Camera Title SetupPress the Tele button Press the FAR button Area Title SetupMove the cursor to Area Title Edit and press the SET button Repeat steps 5 to 7 for each area titleRepeat steps 5 to 7 for each alarm title Alarm Title SetupDisplay the Setup menu on the camera Home Motion Detect menu Home Motion Detect SetupMove the cursor to Area Edit and press the SET button Area Edit screenAdjust the viewing angle of the start position Auto PAN SetupSet the auto pan mode and speed Auto Patrol Setup Set the patrol start position Auto Trace SetupMove the cursor to Autotrace SET and press the SET button Auto Trace SET screen is displayedPosition Function SET screen Position Title SetupRepeat steps 5 to 7 for each title character Position Title screenCeiling plate Attaching a Ceiling Flush Mount Bracket Optional WB-S575Clamp the Ceiling Flush Mount Bracket Connection Cables Attach the Ceiling Mount to the Ceiling Flush Mount BracketAttach the ceiling panel Remove the camera Removing a Ceiling Flush Mount Bracket Optional WB-S575Remove the ceiling panel Check the release labels thoroughly before removalPower cannot be TroubleshootingSymptom Cause Information Remedy Turned onPan/Tilt Mechanism SpecificationsCamera GeneralCeiling mount hole External dimensions Unit mmDimensions in combination with the WB-S575 WB-S575 Ceiling flush mount bracket + Ceiling panelTK-C676 Dome Type Camera