JVC TK-C676 Attach the Ceiling Mount to the Ceiling Flush Mount Bracket, Attach the ceiling panel

Page 39

Anchor bolt mount holes

 

Lock

Ceiling flush mount

screw

 

bracket attached to the

 

ceiling

 

Ceiling mount

4.P. 14, “Connection Cables”

5.Attaching a safety wire to the ceiling mount.Connect cables to the Ceiling Mount.

Attach a safety wire to the ceiling mount and to the ceiling slab or channel to prevent the unit from dropping. First attach the safety wire to the ceiling mount by passing the wire through the safety wire hole.

P. 16, step 1. “Attaching a safety wire”.

6.Attach the Ceiling Mount to the Ceiling Flush Mount Bracket.

Attach the Ceiling Mount to the Ceiling Flush Mount Bracket, tak- ing care not to catch the connection cables.

Please use the four screws provided (M4 x 12 mm). If the screws that have been removed in step 2. above are used, the camera may not be installed properly and may fall.

Attach so that the lock screw of the Ceiling Mount is positioned be- low the anchor bolt mount hole of the Ceiling Flush Mount Bracket.

Hook

MEMO

7. Attach the camera to the Ceiling Mount. P. 16, “Attaching the Camera”

Ceiling panel

8. Attach the ceiling panel.

Attach the ceiling panel, provided with the Ceiling Flush Mount Brack- et, by attaching the two hooks one by one.

Both the ceiling flush mount bracket and the drop prevention attachment should be insulated from the ceiling structure.

If the ceiling structure is made of a metallic material, an improper insulation with the camera may produce noise in the video.

39

Image 39 Contents
TK-C676 Important Safeguards Contents Instructions Ceiling mount FeaturesProvided Accessories Safety Precautions Zooming Precautions for Correct Operation Preset positions Camera setups with which auto focusing may be difficult Ceiling Mount Controls, Connectors and IndicatorsConnector Male Camera Connector Female$ Machine ID Switch Setting SwitchesCable connections P Switch settings PObserve the following points when connecting compo Multi-Drop Communication SystemMemo Switch 7 OFF Switch 8 on Point-to-Point Communication SystemTerminal side of the Ceiling Mount For example connection with an RM-P2580 Camera Four wires must be connectedTwo wires must be connected Duplex Setting switches Switch SettingsExample Camera ID check procedureMachine ID Bers on the RM-P2580Remove the cover from the Ceiling Mount Cable ConnectionsMake a 90 mm diameter hole in the ceiling Connect the cablesAttach the cover Attaching the Camera Attaching a safety wireAttach the drop prevention wire Attaching the Ceiling MountTighten the lock screw Ensure that the lock screw is looseFit the camera Rotate the cameraPress the SET button Setup ProcedureSetting the camera menus from an RM-P2580 Press and hold the Menu button for 3 secondsNormal screen Menu for setting up the home posi- tion onlyMenu for setting up the function of each preset position Menu Screen FlowCamera Function Screen Camera TITLE/ALARM Screen Alarm OUT1 Alarm Input PolarityAlarm Alarm OutputCamera ALC/ExDR screen Camera Video Adjustment ScreenSense UP AGC ModeExDR Mode 10 dBLOW ColourMode LevelDemonstration Alarm DisplayHome Motion Detect Screen Area EditAuto PAN/PATROL/TRACE Screen Position Function SET Screen Factory Settings screenPrivate Mask Setup Camera Title Setup Press the Tele buttonRepeat steps 5 and 6 for each title character Repeat steps 5 to 7 for each area title Area Title SetupMove the cursor to Area Title Edit and press the SET button Press the FAR buttonAlarm Title Setup Display the Setup menu on the cameraRepeat steps 5 to 7 for each alarm title Area Edit screen Home Motion Detect SetupMove the cursor to Area Edit and press the SET button Home Motion Detect menuAuto PAN Setup Set the auto pan mode and speedAdjust the viewing angle of the start position Auto Patrol Setup Auto Trace SET screen is displayed Auto Trace SetupMove the cursor to Autotrace SET and press the SET button Set the patrol start positionPosition Title screen Position Title SetupRepeat steps 5 to 7 for each title character Position Function SET screenAttaching a Ceiling Flush Mount Bracket Optional WB-S575 Clamp the Ceiling Flush Mount BracketCeiling plate Attach the Ceiling Mount to the Ceiling Flush Mount Bracket Attach the ceiling panelConnection Cables Check the release labels thoroughly before removal Removing a Ceiling Flush Mount Bracket Optional WB-S575Remove the ceiling panel Remove the cameraTurned on TroubleshootingSymptom Cause Information Remedy Power cannot beGeneral SpecificationsCamera Pan/Tilt MechanismWB-S575 Ceiling flush mount bracket + Ceiling panel External dimensions Unit mmDimensions in combination with the WB-S575 Ceiling mount holeTK-C676 Dome Type Camera