Axis Communications P5414-E user manual Connectors, Terminal Connector

Page 65

AXIS P5414–E PTZ Dome Network Camera

Technical Specifications

Function/group

Item

Specifications

 

 

 

 

Operating

Temperature: –20 °C to 50 °C (–4 °F to 122 °F)

 

conditions

Humidity 10–100% RH (condensing)

 

 

 

 

Approvals

EN 50121–4, IEC 62236–4, EN 55022 Class B, EN 61000-6-1, EN 61000-6-2,

 

 

EN 55024, FCC Part 15 Subpart B Class B, ICES-003 Class B, VCCI Class B,

 

 

C-tick AS/NZS CISPR 22 Class B, KCC KN22 Class B, KN24, IEC/EN/UL 60950-1,

 

 

IEC/EN/UL 60950-22, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-6, IEC 60068-2-14,

 

 

IEC 60068-2-27, IEC 60068-2-30, IEC 60068-2-78, IEC 60529 IP66, EN 50581,

 

 

NEMA 250 Type 4X, ISO 4892-2

 

 

 

 

Weight

3.5 kg (7.7 lb)

 

 

 

 

Included

Installation Guide, AVHS Authentication key, installation and management software CD,

 

accessories

Windows decoder 1–user license

 

 

 

 

Video

AXIS Camera Companion (included), AXIS Camera Station and video management

 

management

software from Axis’ Application Development Partners (not included). For more

 

software (sold

information, see www.axis.com/products/video/software

 

separately)

 

 

Optional

AXIS P54 Smoked dome

 

accessories

T8123 High PoE-30W Midspan 1-port

 

 

AXIS T94P01B Corner Bracket

 

 

AXIS T8310 Video Surveillance Control Board

 

 

AXIS T90A Illuminators

 

 

AXIS High PoE midspans

 

 

Installation Display

 

 

Multi-user decoder license pack

 

 

 

Connectors

I/O Terminal Connector

6–pin terminal block for:

• Digital Input

• Digital Output

• 0 V DC (-)

Function

Pin

Notes

Specifications

 

 

 

 

0 V DC (-)

1

 

0 V DC

 

 

 

 

DC output

2

Can be used to power auxiliary equipment.

12 V DC Power

 

 

Note: This pin can only be used as power out.

Max load = 50 mA

 

 

 

 

Configurable

3–6

Digital input – Connect to pin 1 to activate, or leave floating

0 to +30 V DC

(Input or Output)

 

(unconnected) to deactivate.

 

 

 

 

 

 

 

Digital output – Connected to pin 1 when activated, floating

Max load = 100 mA

 

 

(unconnected) when deactivated. If used with an inductive

Max voltage = +30 V DC

 

 

load, e.g. a relay, a diode must be connected in parallel with

 

 

 

the load, for protection against voltage transients.

 

 

 

 

 

65

Image 65
Contents Axis P5414-E PTZ Dome Network Camera Legal Considerations About this DocumentLiability Intellectual Property RightsLearn More SupportAxis P5414-E PTZ Dome Network Camera Table of ContentsConnectors Performance Considerations Network Connector Connectors and ButtonsFor technical specifications, see RJ45 Ethernet connector with Power over Ethernet Plus PoE+Power Connector ConnectorAudio Connector SD Card SlotCompleted LED IndicatorsColor Indication Start a browser Internet Explorer, Firefox, Safari Access the ProductAccess from a Browser Click Use Https Access from the InternetSet the Root Password Live View Go to Setup EventsControls on the Live View Manual TriggerPTZ Controls Axis Media Control viewer toolbarTo show the manual trigger buttons in the Live View AMC Audio ControlsAxis P5414-E PTZ Dome Network Camera Axis Media Control AMC How to Stream H.264Media Streams QuickTimeTM. The following paths can be used Alternative Methods of Accessing the Video StreamJava applet supports simplex audio with G.711 encoding Access Audio StreamsBasic Setup Set Up the ProductImage Video and AudioVideo Stream 264 Click Save to apply the new settingsStream Profiles Camera SettingsShutter & Gain OverlaySet Shutter to Day/NightGo to Video & Audio Overlay Image Overlay ImageGo to Video & Audio Video Stream and select the Image tab Go to Events Action Rules Privacy MaskUse Overlay Text in an Action Rule Audio Input Audio SettingsAudio Modes Audio Output Audio ClipsDefault Viewer for Browsers Configure the Live ViewGo to Setup Live View Config Viewer SettingsUser Defined Links Output ButtonsAxis P5414-E PTZ Dome Network Camera PTZ Pan Tilt Zoom Preset PositionsGatekeeper Guard TourAdvanced Osdi ZonesLimits Formats in the online helpControls Control QueueOperator Same as administrator but with lower priority Detectors Set Up Motion Detection WindowsMotion Detection Go to Detectors Motion DetectionMotion Detection Parameters Audio DetectionGo to Setup Applications Install ApplicationApplications Application LicensesAxis P5414-E PTZ Dome Network Camera Events Set Up Action RulesConvert Event Types to Action Rules Go to Events Action Rules and click AddTriggers Recipient Types Add RecipientsActions Recipient Use with action Set Up Email RecipientsCreate Schedules Set Up RecurrencesTo create a new schedule Go to Events Schedules and click AddRecording List RecordingsContinuous Recording Go to Recordings ListClick Save to save and start the recording Languages Security System OptionsUsers IP Address FilterGo to System Options Security Ieee IeeeCertificates Go to Setup System Options Security Certificates To install a self-signed certificateClick Install certificate and upload the certificate Date & TimeNetwork Basic TCP/IP SettingsAxis Internet Dynamic DNS Service Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service requires IPv4 DNS ConfigurationHost Name Configuration NTP ConfigurationLink-Local IPv4 Address NAT traversal port mapping for IPv4FTP QoS Quality of ServiceSmtp email UPnPTM can be disabled under System Options Network UPnPTMUPnPTM RTP/H.264Bonjour StorageSD Card Network SharePorts & Devices MaintenancePorts Port StatusSupport Overview SupportSystem Overview Logs & ReportsFile Upload Reset to Factory Default SettingsPlain Config Repainting the Camera Upgrade the Firmware TroubleshootingFirmware To upgrade the product’s firmware Check the FirmwareEmergency Recovery Procedure Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product cannot be accessed from a browserBasic Product is accessible locally but not externallyProblems with streaming H.264 Setup Video & Audio Camera Settings Video and image problems, generalSettings Storage and disk management problemsVideo cannot be recorded Technical Specifications Installation Function/group Specifications Network SecurityMaintenance General Casing PowerTerminal Connector ConnectorsFunction Pin Tip Performance ConsiderationsAudio Input Microphone/LineM3.2