Axis Communications Q6045-C PTZ user manual Object Removed, Enter/Exit Detector

Page 33

AXIS Q6045-C PTZ Dome Network Camera

Detectors

Parameter

Object Size

History

Sensitivity

 

 

 

 

Description

Object size relative to window

Object memory length.

Difference in luminance

 

size.

 

between background and

 

 

 

object.

 

 

 

 

High level (100%)

Only very large objects trigger

An object that appears in

Ordinary colored objects on

 

motion detection.

the window triggers motion

ordinary backgrounds trigger

 

 

detection for a long time

motion detection.

 

 

before it is considered as

 

 

 

non-moving.

 

 

 

 

 

Medium level (50%)

 

 

A large difference in luminance

 

 

 

is required to trigger motion

 

 

 

detection.

 

 

 

 

Low level (0%)

Even very small objects trigger

An object that appears in

Only very bright objects on

 

motion detection.

the window triggers motion

a dark background trigger

 

 

detection only for a very short

motion detection.

 

 

time before it is considered as

 

 

 

non-moving.

 

 

 

 

 

Recommended values

5–15%

60–90%

75–95%

 

 

 

 

Default values

15%

90%

90%

 

 

 

 

Note

To trigger on small objects or movements, use several small motion detection windows rather than one large window and select a low object size.

To avoid triggering on small objects, select a high object size.

While monitoring an area where moving objects are not expected, select a high history level. This will cause motion detection to trigger as long as the object is present in the window.

To only detect flashing light, select a low sensitivity. In other cases high sensitivity is recommended.

Object Removed

Object Removed is used to trigger an alarm if an object, within a pre-defined area of interest, is removed. Object Removed provides tools to define:

Area of interest - This is a virtual area that is defined around an object to detect if that object has been removed from the scene.

Object size - Defines the size of the objects that should be detected.

Sensitivity - Use this slidebar to define how sensitive the detection should be.

Drawing Opacity - Use this slidebar to define how transparent the area of interest shape should be. Note that, this change will not be saved.

See the online help for more information.

Enter/Exit Detector

Enter/Exit Detector is used to trigger an alarm if an object, within a pre-defined area of interest, has entered or left the area. Enter/Exit Detector provides tools to define:

Area of interest - This is a virtual area that is defined to detect moving objects entering a defined area

Object size - Defines the size of the objects that should be detected.

Sensitivity - Use this slidebar to define how sensitive the detection should be.

33

Image 33 Contents
Axis Q6045-C PTZ Dome Network Camera Legal Considerations About this DocumentLiability Intellectual Property RightsLearn More SupportAxis Q6045-C PTZ Dome Network Camera Table of ContentsMulti-Connector Cable Troubleshooting For technical specifications, see Connectors and ButtonsHardware Overview CameraMulti-connector LED IndicatorsPower Button SD Card SlotMedia Converter Switch Connectors Media Converter SwitchNetwork Connector Dip Switches Dip switch positionConnector internal 2-pin I/O terminal block Description Media Converter Switch LED IndicatorsAccess from a Browser Access the ProductAccess from the Internet Set the Root PasswordLive View Go to Setup EventsControls on the Live View Click Use HttpsAxis Media Control viewer toolbar PTZ ControlsTo show the manual trigger buttons in the Live View Axis Q6045-C PTZ Dome Network Camera How to Stream H.264 Media StreamsAxis Media Control AMC QuickTimeTM. The following paths can be used Alternative Methods of Accessing the Video StreamAxis Q6045-C PTZ Dome Network Camera Basic Setup Set Up the ProductVideo Click Save to apply the new settingsVideo Stream Pixel Counter264 Stream ProfilesExposure Settings Camera SettingsImage Appearance White BalanceOverlay Image SettingsOverlay Image Go to Video Video Stream and select the Image tabGo to Events Action Rules Use Overlay Text in an Action RulePrivacy Mask Default Viewer for Browsers Configure the Live ViewViewer Settings Browser Viewer DescriptionUser Defined Links Go to Setup Live View ConfigOutput Buttons For more information about I/O ports, see I/O Ports onGo to PTZ Preset Positions Preset PositionsPTZ Pan Tilt Zoom GatekeeperAutotracking ConfigurationExclude Areas Max Limits Tour Recording Guard Tour To add a guard tour To add a recorded tourAdvanced Osdi ZonesLimits ControlsControl Queue Operator Same as administrator but with lower priorityDetectors Set Up Motion Detection WindowsShock Detection Motion DetectionEnter/Exit Detector Object RemovedObject Counter Fence DetectorGo to Setup Applications Install ApplicationApplications Application LicensesAxis Q6045-C PTZ Dome Network Camera Events Set Up Action RulesConvert Event Types to Action Rules Go to Events Action Rules and click AddTriggers Add Recipients ActionsRecipient Types Recipient Use with action Set Up Email RecipientsCreate Schedules Set Up RecurrencesTo create a new schedule Go to Events Schedules and click AddRecording List RecordingsContinuous Recording Go to Recordings ListLanguages Security System OptionsUsers IP Address FilterIeee CertificatesGo to System Options Security Ieee Go to Setup System Options Security Certificates Basic TCP/IP SettingsDate & Time NetworkIPv6 Address Configuration IPv4 Address ConfigurationAssign IP Address Using ARP/Ping ARP/PingAxis Internet Dynamic DNS Service Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service requires IPv4 DNS ConfigurationHost Name Configuration NTP ConfigurationLink-Local IPv4 Address NAT traversal port mapping for IPv4Smtp email QoS Quality of ServiceUPnPTM UPnPTM can be disabled under System Options Network UPnPTMRTP/H.264 BonjourSD Card StorageMount and Unmount SD Card Format SD CardPorts & Devices MaintenanceNetwork Share PortsSupport Overview SupportSystem Overview Logs & ReportsPlain Config Reset to Factory Default SettingsScripting File UploadAxis Q6045-C PTZ Dome Network Camera Function Pin wire Specifications Multi-Connector CableActivated, floating unconnected when Drain, 100 mA Green/white Ethernet receivingUpgrade the Firmware TroubleshootingEmergency Recovery Procedure Check the FirmwareProblems setting the IP address Symptoms, Possible Causes and Remedial ActionsProduct cannot be accessed from a browser Product is accessible locally but not externallyVideo and image problems, general Problems with streaming H.264Video Camera Settings Key framesMedia converter switch Storage and disk management problemsStorage disruption Re-mount the storage deviceTechnical Specifications Installation aid Function/group Specifications System ApplicationMaintenance PowerWeight Function/group SpecificationsAccessories IncludedConnectors Camera ConnectorsExternal Connectors DC input DC output Power out DC, 50 mAMax load = 7 a Separately DC, min 75 WM4.2