Set up motion detection

To set up a motion detection Include Window, follow these instructions:

1.Go to Detectors > Motion Detection.

2.Select the Configure Included Windows option and click New. Select the new window in the list of windows and enter a descriptive name.

3.Adjust the size (drag the bottom right-hand corner) and the position (click on the text at the top and drag to the desired position) of the active window (window with red frame).

4.Adjust the Object Size, History and Sensitivity profile sliders (see Motion detection parameters for details). Any detected motion within an active window is indicated by red peaks in the Activity window.

5.Click Save.

To exclude parts of the include window, select the Configure Excluded Windows and position the exclude window within the include window.

To delete an include or exclude window, select the window in the list of windows and click Del.

Motion detection parameters

The parameters controlling motion detection are described in the table below:

Parameter

Object Size

History

Sensitivity

 

 

 

 

Description

Object size relative to window

Object memory length.

Difference in luminance

 

size.

 

between background and

 

 

 

object.

 

 

 

 

High level (100%)

Only very large objects trigger

An object that appears in

Ordinary colored objects on

 

motion detection.

the window triggers motion

ordinary backgrounds trigger

 

 

detection for a long time

motion detection.

 

 

before it is considered as

 

 

 

non-moving.

 

 

 

 

 

Medium level (50%)

 

 

A large difference in luminance

 

 

 

is required to trigger motion

 

 

 

detection.

 

 

 

 

24

Image 24
Contents Axis M3113-R Network Camera About this document LiabilityIntellectual Property Rights Equipment ModificationsTable of Contents Axis M3113-R Network CameraConnectors Hardware overviewHardware overview LED indicators MaintenanceColor Indication Accessing the product Accessing the productAccess from a browser Access from the Internet Set the root passwordNetwork TCP/IP Advanced Click Create self-signed certificateSet Power Line Frequency Live ViewControls on the Live View Axis Media Control viewer toolbar PTZ ControlsAxis M3113-R Network Camera How to stream H.264 Media streamsMedia streams Axis Media Control AMCAlternative methods of accessing the video stream Axis M3113-R Network Camera Setting up the product Setting up the productBasic Setup Video VideoVideo Stream Pixel CounterStream Profiles Image264 Camera Settings View AreaOverlay Privacy MaskOverlay image Default viewer for browsers Live View ConfigLive View Config Viewer Settings User Defined LinksBrowser Viewer Description Preset Positions PTZ Pan Tilt ZoomPTZ Pan Tilt Zoom Guard TourAdvanced ControlsDetectors DetectorsCamera Tampering Motion DetectionSet up motion detection Motion detection parametersDefault values Low level 0%Recommended values Applications ApplicationsEvents EventsSetting Up an Action Rule Convert Event Types to Action RulesGo to Events Action Rules and click Add Recipients SchedulesRecurrences Axis M3113-R Network Camera Recordings RecordingsRecording List Continuous recordingAxis M3113-R Network Camera System Options System OptionsSecurity UsersDate & Time IeeeBasic TCP/IP Settings NetworkAdvanced TCP/IP Settings Http NAT traversal port mapping for IPv4QoS Quality of Service Smtp emailStorage UPnPTMRTP/H.264 BonjourMaintenance SupportSupport Overview System OverviewReset to factory default settings ScriptingFile Upload Plain ConfigTroubleshooting TroubleshootingEmergency recovery procedure Checking the firmwareSymptoms, possible causes and remedial actions Problems setting the IP addressProduct cannot be accessed from a browser Product is accessible locally but not externally Problems with the H.264 formatStatus and Network indicator LEDs are flashing red rapidly Video and image problems, general Video Camera SettingsProblems uploading files No images displayed on webMotion Detection triggers unexpectedly Changes in luminanceTechnical Specifications Technical SpecificationsMaintenance Installation aids Memory PowerConnectors Temperature ApprovalsFunction/group Specifications Weight Kg 0.6 lb Included Accessories License VideoPerformance considerations M1.4