AXIS M1011/M1011-W/M1031-W - System Options
Bonjour
The network cameras include support for Bonjour. When enabled, the camera is automatically detected by operating systems and clients that support this.
Ports & Devices
I/O Ports
This page shows the normal and current state of the PIR Sensor.
PIR Sensor
PIR Sensor State - This setting shows the current state of the PIR Sensor.
Sensitivity Settings - Sensitivity Settings is used to adjust the sensitivity of the PIR Sensor from 0 - 100%. The default sensitivity is 75%.
By increasing the sensitivity, the range of the PIR Sensor is also increased. The PIR Sensor can be configured to detect movement in the dark up a maximum range of 6 meters. Move the Sensitivity slider to adjust the PIR Sensor’s sensitivity and range.
LED Settings
The Status indicator LED on the front of the camera can be set to flash at a configurable interval (or to not light up at all)
when the unit is accessed. For a listing of all LED behavior, see page 6, or the online help .
Notes:
•The illumination LED is not intended for constant operation, and has an estimated life span of 30 000 hours.
•The LED can not be replaced.
•The LED should only be used for short periods when viewing video or when motion is detected.
Maintenance
•Restart - the camera is restarted without changing any settings.
•Restore - the unit is restarted and most current settings are reset to factory default values. The settings that do not reset are:
•the boot protocol (DHCP or static)
•the static IP address
•the default router
•the subnet mask
•the system time
•Default - the default button should be used with caution. Pressing this returns the camera's settings to the factory default values (including the IP address).
Upgrade Server - See Upgrading the Firmware, on page 36.
Support
Support Overview
The Support Overview page provides valuable information on troubleshooting and contact information, should you require technical assistance.
33