Bosch Appliances VBN-5085 Day/Night switching, Camera control communication Bilinx

Page 23

DINION 5000 AN

Configuration en 23

 

 

5.3Day/Night switching

The camera is equipped with a motorized IR filter. The mechanical IR filter can be removed in low-light or IR illuminated applications by software configuration settings. If Auto switching mode is selected, the camera automatically switches the filter depending on the observed light level. The switching level is programmable. In Auto switching mode the camera prioritizes motion (the camera gives sharp images without motion blur as long as the light level permits) or color (the camera gives color pictures as long as the light level permits). The camera recognizes IR illuminated scenes to prevent unwanted switching to color mode.

There are four different methods of controlling the IR filter:

via an alarm input,

via Bilinx communication,

automatically, based on the observed light levels, or

as part of the programmable mode profile.

5.4Camera control communication (Bilinx)

This camera is equipped with a coaxial communications transceiver (also referred to as Bilinx). In combination with VP- CFGSFT, the camera setting can be changed from any point along the coaxial cable. All menus can be accessed remotely giving full control of the camera. With this method of communication it is also possible to disable the local keys on the camera.To avoid loss of communication on an installed camera, the Communication On/Off selection is not available while using remote control. This function can only be accessed with the camera buttons. Bilinx communications can only be disabled using the buttons on the camera.

Disabled camera buttons

When the Bilinx communications link is active, the buttons on the camera are disabled.

Bosch Security Systems

Installation Manual

AM18-Q0644 v1.0 2013.03

Image 23
Contents Dinion 5000 AN Page Table of Contents Technical Data TroubleshootingMaintenance System ground/Safety ground SafetySafety precautions Important safety instructions Important notices FCC & Ices Information FCC informationMore information UL certificationBosch notice DisclaimerIntroduction FeaturesUnpacking InstallationLow voltage cameras Power connectionConnection and mounting High voltage cameras High voltage power connectionVideo connections Output Video signalPin Alarm socket Alarm and relay connectorPin Video iris lens DC iris lens Lens mountingBack focus adjustment Lock the back focus locking button Mounting the camera Top level menus ConfigurationMenus Side panel door .2 Menu/select key Menu navigationAM18-Q0644 v1.0 Installation Manual Camera control communication Bilinx Day/Night switchingDisabled camera buttons Selection Description Mode submenuMain menu structure Exposure submenu En ConfigurationDINION 5000 AN 3 Day/Night submenu Selection Description HDR Enhance / Dynamic Engine submenu3D-NR Color submenu Selecting an area for VMD masking VMD submenuImage Adjustment submenu Install menu structure Lens Wizard submenu Language submenuAdjustment procedure Manual-iris Lens Adjustment procedure DC-iris LensSynchronization submenu Alarm I/O submenu Connections submenu Test signal submenuCamera ID submenu Selecting an area for privacy masking Privacy masking submenuFlip submenu Defaults submenu Malfunction Possible causes Solution TroubleshootingResolving problems Customer service Transfer and disposal MaintenanceRepairs All versions Technical DataSpecifications Type number VBN-5085-C11 VBN-5085-C21 VBN-5085-C51Technical Data en 889 123 843 DimensionsAccessories Dinion 5000 AN Page Bosch Security Systems