DINION 5000 AN | Configuration en 23 |
|
|
5.3Day/Night switching
The camera is equipped with a motorized IR filter. The mechanical IR filter can be removed in
There are four different methods of controlling the IR filter:
–via an alarm input,
–via Bilinx communication,
–automatically, based on the observed light levels, or
–as part of the programmable mode profile.
5.4Camera control communication (Bilinx)
This camera is equipped with a coaxial communications transceiver (also referred to as Bilinx). In combination with VP- CFGSFT, the camera setting can be changed from any point along the coaxial cable. All menus can be accessed remotely giving full control of the camera. With this method of communication it is also possible to disable the local keys on the camera.To avoid loss of communication on an installed camera, the Communication On/Off selection is not available while using remote control. This function can only be accessed with the camera buttons. Bilinx communications can only be disabled using the buttons on the camera.
Disabled camera buttons
When the Bilinx communications link is active, the buttons on the camera are disabled.
Bosch Security Systems | Installation Manual |