DINION 5000 AN | Configuration en 25 |
|
|
5.5.2Exposure submenu
Item | Selection | Description |
|
|
|
ALC level | Selects the video level range. A | |
|
| positive value is more useful for low- |
|
| light conditions; a negative value is |
|
| more useful for very bright |
|
| conditions. |
|
| Some ALC adjustment may improve |
|
| scene content when Smart BLC is |
|
| enabled. |
|
|
|
ALC speed | Slow, | Adjusts the speed of the video level |
| medium, fast | control loop. For most scenes it |
|
| should remain at the default value. |
|
|
|
Shutter | AES, FL, Fixed | AES |
|
| automatically sets the optimum |
|
| shutter speed. |
|
| FL - flickerless mode avoids |
|
| interference from light sources |
|
| (recommended for |
|
| only). |
|
| FIXED - allows a user defined shutter |
|
| speed. |
|
|
|
Default (AES) | 1/50 (PAL) | In DEFAULT (AES) mode, the camera |
shutter | 1/60 (NTSC), | tries to maintain the selected shutter |
or | 1/100 (PAL) | speed as long as the light level of the |
Fixed shutter | 1/120 (NTSC), | scene is high enough. |
| 1/250, | In Fixed mode, selects shutter |
| 1/500, | speed. |
| 1/1000, |
|
| 1/2000, |
|
| 1/4000, |
|
| 1/10K, |
|
| 1/100K |
|
|
|
|
Bosch Security Systems | Installation Manual |