Bosch Appliances VBN-5085 installation manual Safety precautions, System ground/Safety ground

Page 5

DINION 5000 AN

Safety en

5

 

 

 

1Safety

1.1Safety precautions

DANGER!

High risk: This symbol indicates an imminently hazardous situation such as "Dangerous Voltage" inside the product. If not avoided, this will result in an electrical shock, serious bodily injury, or death.

WARNING!

Medium risk: Indicates a potentially hazardous situation.

If not avoided, this could result in minor or moderate bodily injury.

CAUTION!

Low risk: Indicates a potentially hazardous situation.

If not avoided, this could result in property damage or risk of damage to the unit.

1.2System ground/Safety ground

System (video) ground is indicated by the symbol .

Safety (power) ground is indicated by the symbol .

The system ground is only used to comply with safety standards or installation practices in certain countries. Bosch does not recommend connecting system ground to safety ground unless it is explicitly required. However, if the system ground and safety ground are connected and grounding loops are causing interference in the video signal, use an isolation transformer (available separately from Bosch).

CAUTION!

Connecting System ground to Safety ground may result in ground loops that can disrupt the CCTV system.

Bosch Security Systems

Installation Manual

AM18-Q0644 v1.0 2013.03

Image 5
Contents Dinion 5000 AN Page Table of Contents Technical Data TroubleshootingMaintenance System ground/Safety ground SafetySafety precautions Important safety instructions Important notices FCC & Ices Information FCC informationBosch notice UL certificationDisclaimer More informationIntroduction FeaturesUnpacking InstallationLow voltage cameras Power connectionConnection and mounting High voltage cameras High voltage power connectionVideo connections Output Video signalPin Alarm socket Alarm and relay connectorPin Video iris lens DC iris lens Lens mountingBack focus adjustment Lock the back focus locking button Mounting the camera Top level menus ConfigurationMenus Side panel door .2 Menu/select key Menu navigationAM18-Q0644 v1.0 Installation Manual Camera control communication Bilinx Day/Night switchingDisabled camera buttons Selection Description Mode submenuMain menu structure Exposure submenu En ConfigurationDINION 5000 AN 3 Day/Night submenu Selection Description HDR Enhance / Dynamic Engine submenu3D-NR Color submenu Selecting an area for VMD masking VMD submenuImage Adjustment submenu Install menu structure Lens Wizard submenu Language submenuAdjustment procedure Manual-iris Lens Adjustment procedure DC-iris LensSynchronization submenu Alarm I/O submenu Connections submenu Test signal submenuCamera ID submenu Selecting an area for privacy masking Privacy masking submenuFlip submenu Defaults submenu Malfunction Possible causes Solution TroubleshootingResolving problems Customer service Transfer and disposal MaintenanceRepairs Specifications Technical DataType number VBN-5085-C11 VBN-5085-C21 VBN-5085-C51 All versionsTechnical Data en 889 123 843 DimensionsAccessories Dinion 5000 AN Page Bosch Security Systems